| Plan Review Stops For Permit 09120583 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2010-03-31 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2010-03-31 |
Time |
13:44 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2010-03-31 |
Time |
13:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2010-01-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2010-01-05 |
Time |
08:20 |
Rev Time |
1.50 |
| Received By |
jwitmer |
Date |
2010-01-05 |
Time |
08:20 |
Sent To |
|
|
| Notes |
| 2010-01-05 10:45:43 | BUILDING PLAN REVIEW | | | PERMIT: 09120583 | | | ADD: 1100 N OLIVE | | | CONT: P & T CONSTRUCTION, INC | | | TEL: (561324-8055 | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | JAN. 05/ 2009 | | | | | | 1) THE COVERSHEET OF THE PLANS INDICATE A CHANGE OF | | | OCCUPANCY FROM RESIDENTIAL TO BUSINESS, THIS WILL | | | TRIGGER THE REVIEW UNDER THE 2007 EXISTING BUILDING | | | CODE CHAPTER 9 FOR CHANGE IN OCCUPANCY. | | | | | | 1A) 2007 EXIST BLDG CODE 907.1 GRAVITY LOADS. BUILDINGS | | | OR PORTIONS THEREOF SUBJECT TO A CHANGE OF OCCUPANCY | | | WHERE SUCH CHANGE IN THE NATURE OF OCCUPANCY RESULTS IN | | | HIGHER UNIFORM LOADS BASED ON THE FLORIDA BUILDING | | | CODE, BUILDING TABLE 1607.1 SHALL COMPLY WITH THE | | | GRAVITY LOAD PROVISIONS OF THE FLORIDA BUILDING CODE, | | | BUILDING. | | | | | | FBC, BUILDING TABLE 1607.1 (28) RESIDENTIAL OCCUPANCY | | | FOR SLEEPING ROOM LOADS ARE 30 PSF, THE LIVABLE AREAS | | | 40 PSF AND 40 PSF FOR STAIRS IN ONE AND TWO FAMILY | | | DWELLINGS. THE CHANGE OF OCCUPANCY TO A BUSINESS | | | OCCUPANCY THE FLOOR LOADS ARE INCREASED TO 50PSF AND | | | STAIRS 100 PSF. PLEASE INDICATE COMPLIANCE WITH THIS | | | SECTION. THE EXCEPTION IS STRUCTURAL ELEMENTS WHOSE | | | STRESS IS NOT INCREASED BY MORE THAN 5%. THE CHANGE | | | FROM 40 PSF TO 50 PSF IS A INCREASE OF 8% WHICH EXCEEDS | | | THE EXCEPTION. | | | | | | | | | 1B) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | | | | INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY. | | | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | STARTING AUGUST 21, 2009, THE CONSTRUCTION SERVICES | | | DEPARTMENT WILL BE CLOSED ON FRIDAYS UNTIL FURTHER | | | NOTICE. | | | | | | OPENING HOURS MONDAY - THURSDAY WILL REMAIN AT 8:00 AM | | | - 5:00 PM. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | | | | PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE | | | CUSTOMER SERVICE SURVEY AT: | | | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES | | | | | | CONSTRUCTION SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2010-04-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2010-04-07 |
Time |
15:37 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2010-04-07 |
Time |
15:36 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2010-01-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2010-01-07 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2010-01-07 |
Time |
09:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2010-03-31 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2010-03-31 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2010-03-31 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2010-03-31 11:11:01 | | | | | | | 1100 NORTH OILVE AVENUE | | | PERMIT NUMBER 09120583 | | | | | | | | | 1. ANY ROOMS WHERE THE PORTABLE FIRE EXTINGUISHERS ARE | | | LOCATED SHOULD NOT BE LOCKABLE TO PREVENT ACCESS TO | | | THEM. | | | | | | | | | MIKE CARSILLO, BATTALION CHIEF | | | BUREAU OF FIRE PREVENTION | | | (561) 804-4724 PHONE | | | (561) 804-4774 FAX | | | | | | WESLEY JOLIN, FIRE PROTECTION ENGINEER | | | BUREAU OF FIRE PREVENTION | | | (561) 805-6730 PHONE | | | (561) 804-4774 FAX |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2010-01-14 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2010-01-14 |
Time |
08:06 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2010-01-13 |
Time |
12:58 |
Sent To |
|
|
| Notes |
| 2010-01-14 01:22:58 | *****DENIED***** | | | | | | 01. PLANS NOT SIGNED AND SEALED BY THE | | | ENGINEER/ARCHITECT OF RECORD. | | | | | | 02. THE POINT OF COMPASS SHOWN ON SHEET SP1 IS | | | INCORRECT. THE PROJECT SITE IS NORTH OF 10TH STREET, | | | NOT SOUTH AS INDICATED BY THE POINT OF COMPASS. | | | | | | 03. STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241 - 2004 | | | EDITION. | | | | | | 04. PROVIDE THE PRESCRIPTIVE STRENGHTS FOR THE | | | HANDRAILS AND GUARDRAILS OF THE STAIRS. | | | | | | 05. ON SHEET A2, DISPLAY THE ADDRESS NUMBERS ON THE | | | APPROPIATE EXTERION ELEVATION WHICH FRONTS NORTH OLIVE | | | AVENUE. AS PER LOCAL CODES, ADDRESS NUMBERS SHALL BE NO | | | LESS THAN 6" IN HEIGHT AND NO LESS THAN 1" IN | | | WIDTH/STROKE. | | | | | | 06. NFPA 101, LIFE SAFETY CODE, 2006 EDITION SHALL BE | | | REFERENCED. SINCE THIS IS A CHANGE OF OCCUPANCY, | | | CHAPTER 38 (NEW BUSINESS OCCUPANCY) OF NFPA 101 SHALL | | | BE REFERENCED. | | | | | | 07. VERIFY THAT STAIRS AS PER 7.2.2 AND RAMPS AS PER | | | 7.2.5 ARE IN COMPLIANCE. | | | | | | 08. SPECIFY THE INTERIOR FINISH MATERIALS FOR THE WALLS | | | AND CEILINGS IN TERMS OF CLASS A, CLASS B, OR CLASS C. | | | SPECIFY INTERIOR FLOOR FINISH IN COMPLIANCE WITH | | | 10.2.7.1 OR 10.2.7.2, AS APPLICABLE. | | | | | | 09. SHOW THE LOCATION OF THE PORTABLE FIRE | | | EXTINGUISHERS WHICH SATISFY THE 75" TRAVEL DISTANCE. | | | | | | 10. PLANS INDICATE TWO STORAGE ROOMS ON THE SECOND | | | FLOOR. IDENTIFY THE HAZARD OF THE CONTENTS IN THE | | | STORAGE ROOMS CLASSIFIED AS LOW, ORDINARY, OR HIGH. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING WHERE THE COMMENTS HAVE BEEN | | | ADDRESSED ON THE PLANS | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2011-08-15 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2011-08-15 |
Time |
13:18 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2011-07-25 |
Time |
10:29 |
Sent To |
|
|
| Notes |
| 2011-07-25 10:29:37 | ROUTED TO JW DESK | | | (PLANS RESUBMITTED WITHOUT PROCESSING #) | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2010-03-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-03-30 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-03-30 |
Time |
14:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2010-01-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2010-01-04 |
Time |
09:33 |
Sent To |
|
|
| Notes |
| 2010-01-04 09:33:39 | SENT TO B9. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2011-08-15 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2011-08-15 |
Time |
13:16 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2010-04-22 |
Time |
17:07 |
Sent To |
|
|
| Notes |
| 2011-08-15 13:18:37 | PBC IMPACT FEE SIGNED OFF 6/4/10 SEE PLANS |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2010-03-31 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2010-03-31 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2010-03-31 |
Time |
13:43 |
Sent To |
|
|
| Notes |
| 2010-03-31 13:43:44 | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2010-04-16 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2010-04-16 |
Time |
15:00 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2010-04-16 |
Time |
15:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2010-01-11 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2010-01-11 |
Time |
16:34 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2010-01-11 |
Time |
16:34 |
Sent To |
|
|
| Notes |
| 2010-01-11 16:34:56 | 3 SETS OF PLANS SUBMITTED. 2 SETS STAMPED BECAUSE 3RD | | | SET WAS NOT SIGNED AND SEALED BY THE ARCHITECT OF | | | RECORD. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2010-04-05 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2010-04-05 |
Time |
12:36 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2010-04-05 |
Time |
11:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2010-01-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2010-01-05 |
Time |
15:30 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2010-01-05 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2010-01-05 16:14:48 | DENIED | | | REFERENCE: | | | FBC-2007 EXISTING BUILDING | | | FBC-2007 CHAPTER 11 | | | FBC-2007 CHAPTER 1 | | | FBC-2007 PLUMBING | | | | | | 1. SECTION 906.1 ACCESSIBILITY IN PORTIONS OF BUILDINGS | | | UNDERGOING A CHANGE OF OCCUPANCY CLASSIFICATION SHALL | | | COMPLY WITH CHAPTER 11 OF THE FLORIDA BUILDING CODE, | | | BUILDING. | | | | | | 2. SECTION 11-4.1.3(11) IF TOILET ROOMS ARE PROVIDED, | | | THEN EACH PUBLIC AND COMMON USE TOILET ROOM SHALL | | | COMPLY WITH SECTION 11-4.22. IF BATHING ROOMS ARE | | | PROVIDED, THEN EACH PUBLIC AND COMMON USE BATHROOM | | | SHALL COMPLY WITH SECTION 11-4.23. SUBMIT DETAILS FOR | | | THE TOILET ROOM AND THE BATHROOM SHOWING COMPLIANCE | | | WITH SECTIONS 11-4.22 & 11-4.23 WITH ALL SUBSECTIONS. | | | | | | 3. SHT C1 GENERAL NOTES 01 INDICATES THE PROJECT WAS | | | DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE | | | 2007 RESIDENTIAL EDITION. ALSO INDICATED ON THIS SHEET | | | IS A CHANGE OF OCCUPANCY/USE FROM RESIDENTIAL TO | | | BUSINESS. AS A BUSINESS OCCUPANCY, THE DESIGN SHALL BE | | | IN ACCORDANCE WITH THE FLORIDA BUILDING CODE BUILDING. | | | | | | 4. THE SINK IN THE LOUNGE SHALL BE ACCESSIBLE PER | | | SECTION 906.1 AND 11-4.24. SUBMIT A DETAIL SHOWING | | | COMPLIANCE WITH SECTION 11-4.24 WITH ALL SUBSECTIONS. | | | | | | 5. SHT A-1 A DRINKING FOUNTAIN IS REQUIRED PER TABLE | | | 403.1. PLEASE SHOW THE LOCATION OF THE REQUIRED | | | DRINKING FOUNTAIN AND SUBMIT A DETAIL SHOWING | | | COMPLIANCE WITH SECTION 11-4.15 WITH ALL SUBSECTIONS AS | | | WELL AS SECTION 11-4.1.3(10)(A) PROVISIONS FOR THOSE | | | WHO HAVE DIFFICULTY BENDING OR STOOPING. | | | | | | 6. SHTS A-1 & P2.01 INDICATE THE WATER SUPPLY TO THE | | | SHOWER TO BE TERMINATED AND CAPPED OFF. PER SECTION | | | 1002.4, WHERE A TRAP SEAL IS SUBJECT TO LOSS BY | | | EVAPORATION, A TRAP SEAL PRIMER VALVE SHALL BE | | | INSTALLED. A TRAP SEAL PRIMER VALVE SHALL CONFORM TO | | | ASSE 1018 OR ASSE 1044. | | | | | | 7. A RZPV BACKFLOW IS REQUIRED ON THE WATER SERVICE TO | | | THE BUILDING. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
N |
Date |
2010-04-15 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2010-04-15 |
Time |
12:27 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2010-04-15 |
Time |
12:27 |
Sent To |
|
|
| Notes |
| 2010-04-15 12:28:33 | MINOR IMPROVEMENTS ONLY, ALL INTERIOR. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2010-01-19 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2010-01-19 |
Time |
12:00 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2010-01-19 |
Time |
11:59 |
Sent To |
|
|
| Notes |
| 2010-01-19 12:00:50 | NO ADDITIONAL PARKING REQUIRED FOR THE OFFICE USE. | | | CURRENTLY TWO PARKING SPACES WITH ACCESS FROM OLIVE | | | AVENUE. |
|
|