Plan Review Details - Permit 09120583
Plan Review Stops For Permit 09120583
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2010-03-31 Cont ID  
Sent By jwitmer Date 2010-03-31 Time 13:44 Rev Time 0.77
Received By jwitmer Date 2010-03-31 Time 13:44 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-01-05 Cont ID  
Sent By jwitmer Date 2010-01-05 Time 08:20 Rev Time 1.50
Received By jwitmer Date 2010-01-05 Time 08:20 Sent To  
Notes
2010-01-05 10:45:43BUILDING PLAN REVIEW
 PERMIT: 09120583
 ADD: 1100 N OLIVE
 CONT: P & T CONSTRUCTION, INC
 TEL: (561324-8055
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
 JAN. 05/ 2009
  
 1) THE COVERSHEET OF THE PLANS INDICATE A CHANGE OF
 OCCUPANCY FROM RESIDENTIAL TO BUSINESS, THIS WILL
 TRIGGER THE REVIEW UNDER THE 2007 EXISTING BUILDING
 CODE CHAPTER 9 FOR CHANGE IN OCCUPANCY.
  
 1A) 2007 EXIST BLDG CODE 907.1 GRAVITY LOADS. BUILDINGS
 OR PORTIONS THEREOF SUBJECT TO A CHANGE OF OCCUPANCY
 WHERE SUCH CHANGE IN THE NATURE OF OCCUPANCY RESULTS IN
 HIGHER UNIFORM LOADS BASED ON THE FLORIDA BUILDING
 CODE, BUILDING TABLE 1607.1 SHALL COMPLY WITH THE
 GRAVITY LOAD PROVISIONS OF THE FLORIDA BUILDING CODE,
 BUILDING.
  
 FBC, BUILDING TABLE 1607.1 (28) RESIDENTIAL OCCUPANCY
 FOR SLEEPING ROOM LOADS ARE 30 PSF, THE LIVABLE AREAS
 40 PSF AND 40 PSF FOR STAIRS IN ONE AND TWO FAMILY
 DWELLINGS. THE CHANGE OF OCCUPANCY TO A BUSINESS
 OCCUPANCY THE FLOOR LOADS ARE INCREASED TO 50PSF AND
 STAIRS 100 PSF. PLEASE INDICATE COMPLIANCE WITH THIS
 SECTION. THE EXCEPTION IS STRUCTURAL ELEMENTS WHOSE
 STRESS IS NOT INCREASED BY MORE THAN 5%. THE CHANGE
 FROM 40 PSF TO 50 PSF IS A INCREASE OF 8% WHICH EXCEEDS
 THE EXCEPTION.
  
  
 1B) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
  
 INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 STARTING AUGUST 21, 2009, THE CONSTRUCTION SERVICES
 DEPARTMENT WILL BE CLOSED ON FRIDAYS UNTIL FURTHER
 NOTICE.
  
 OPENING HOURS MONDAY - THURSDAY WILL REMAIN AT 8:00 AM
 - 5:00 PM.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE
 CUSTOMER SERVICE SURVEY AT:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2010-04-07 Cont ID  
Sent By btrobaug Date 2010-04-07 Time 15:37 Rev Time 0.00
Received By btrobaug Date 2010-04-07 Time 15:36 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2010-01-07 Cont ID  
Sent By btrobaug Date 2010-01-07 Time 11:18 Rev Time 0.00
Received By btrobaug Date 2010-01-07 Time 09:09 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2010-03-31 Cont ID  
Sent By mcarsill Date 2010-03-31 Time 11:11 Rev Time 0.00
Received By mcarsill Date 2010-03-31 Time 11:07 Sent To  
Notes
2010-03-31 11:11:01 
  
 1100 NORTH OILVE AVENUE
 PERMIT NUMBER 09120583
  
  
 1. ANY ROOMS WHERE THE PORTABLE FIRE EXTINGUISHERS ARE
 LOCATED SHOULD NOT BE LOCKABLE TO PREVENT ACCESS TO
 THEM.
  
  
 MIKE CARSILLO, BATTALION CHIEF
 BUREAU OF FIRE PREVENTION
 (561) 804-4724 PHONE
 (561) 804-4774 FAX
  
 WESLEY JOLIN, FIRE PROTECTION ENGINEER
 BUREAU OF FIRE PREVENTION
 (561) 805-6730 PHONE
 (561) 804-4774 FAX

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2010-01-14 Cont ID  
Sent By mawillia Date 2010-01-14 Time 08:06 Rev Time 0.00
Received By mawillia Date 2010-01-13 Time 12:58 Sent To  
Notes
2010-01-14 01:22:58*****DENIED*****
  
 01. PLANS NOT SIGNED AND SEALED BY THE
 ENGINEER/ARCHITECT OF RECORD.
  
 02. THE POINT OF COMPASS SHOWN ON SHEET SP1 IS
 INCORRECT. THE PROJECT SITE IS NORTH OF 10TH STREET,
 NOT SOUTH AS INDICATED BY THE POINT OF COMPASS.
  
 03. STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241 - 2004
 EDITION.
  
 04. PROVIDE THE PRESCRIPTIVE STRENGHTS FOR THE
 HANDRAILS AND GUARDRAILS OF THE STAIRS.
  
 05. ON SHEET A2, DISPLAY THE ADDRESS NUMBERS ON THE
 APPROPIATE EXTERION ELEVATION WHICH FRONTS NORTH OLIVE
 AVENUE. AS PER LOCAL CODES, ADDRESS NUMBERS SHALL BE NO
 LESS THAN 6" IN HEIGHT AND NO LESS THAN 1" IN
 WIDTH/STROKE.
  
 06. NFPA 101, LIFE SAFETY CODE, 2006 EDITION SHALL BE
 REFERENCED. SINCE THIS IS A CHANGE OF OCCUPANCY,
 CHAPTER 38 (NEW BUSINESS OCCUPANCY) OF NFPA 101 SHALL
 BE REFERENCED.
  
 07. VERIFY THAT STAIRS AS PER 7.2.2 AND RAMPS AS PER
 7.2.5 ARE IN COMPLIANCE.
  
 08. SPECIFY THE INTERIOR FINISH MATERIALS FOR THE WALLS
 AND CEILINGS IN TERMS OF CLASS A, CLASS B, OR CLASS C.
 SPECIFY INTERIOR FLOOR FINISH IN COMPLIANCE WITH
 10.2.7.1 OR 10.2.7.2, AS APPLICABLE.
  
 09. SHOW THE LOCATION OF THE PORTABLE FIRE
 EXTINGUISHERS WHICH SATISFY THE 75" TRAVEL DISTANCE.
  
 10. PLANS INDICATE TWO STORAGE ROOMS ON THE SECOND
 FLOOR. IDENTIFY THE HAZARD OF THE CONTENTS IN THE
 STORAGE ROOMS CLASSIFIED AS LOW, ORDINARY, OR HIGH.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING WHERE THE COMMENTS HAVE BEEN
 ADDRESSED ON THE PLANS
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2011-08-15 Cont ID  
Sent By lmartine Date 2011-08-15 Time 13:18 Rev Time 0.00
Received By lmartine Date 2011-07-25 Time 10:29 Sent To  
Notes
2011-07-25 10:29:37ROUTED TO JW DESK
 (PLANS RESUBMITTED WITHOUT PROCESSING #)
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-03-30 Cont ID  
Sent By shill Date 2010-03-30 Time 14:50 Rev Time 0.00
Received By shill Date 2010-03-30 Time 14:50 Sent To  
Notes
2010-03-30 14:50:34B14
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2010-01-19 Time   Rev Time 0.00
Received By jgomez Date 2010-01-04 Time 09:33 Sent To  
Notes
2010-01-04 09:33:39SENT TO B9.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2011-08-15 Cont ID  
Sent By lmartine Date 2011-08-15 Time 13:16 Rev Time 0.00
Received By lmartine Date 2010-04-22 Time 17:07 Sent To  
Notes
2011-08-15 13:18:37PBC IMPACT FEE SIGNED OFF 6/4/10 SEE PLANS

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2010-03-31 Cont ID  
Sent By jwitmer Date 2010-03-31 Time 13:43 Rev Time 0.00
Received By jwitmer Date 2010-03-31 Time 13:43 Sent To  
Notes
2010-03-31 13:43:44BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2010-04-16 Cont ID  
Sent By hmoser Date 2010-04-16 Time 15:00 Rev Time 0.00
Received By hmoser Date 2010-04-16 Time 15:00 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2010-01-11 Cont ID  
Sent By rregueir Date 2010-01-11 Time 16:34 Rev Time 0.00
Received By rregueir Date 2010-01-11 Time 16:34 Sent To  
Notes
2010-01-11 16:34:563 SETS OF PLANS SUBMITTED. 2 SETS STAMPED BECAUSE 3RD
 SET WAS NOT SIGNED AND SEALED BY THE ARCHITECT OF
 RECORD.

Review Stop P PLUMBING
Rev No 2 Status P Date 2010-04-05 Cont ID  
Sent By lwagner Date 2010-04-05 Time 12:36 Rev Time 0.00
Received By lwagner Date 2010-04-05 Time 11:44 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2010-01-05 Cont ID  
Sent By kstevens Date 2010-01-05 Time 15:30 Rev Time 0.00
Received By kstevens Date 2010-01-05 Time 15:30 Sent To  
Notes
2010-01-05 16:14:48DENIED
 REFERENCE:
 FBC-2007 EXISTING BUILDING
 FBC-2007 CHAPTER 11
 FBC-2007 CHAPTER 1
 FBC-2007 PLUMBING
  
 1. SECTION 906.1 ACCESSIBILITY IN PORTIONS OF BUILDINGS
 UNDERGOING A CHANGE OF OCCUPANCY CLASSIFICATION SHALL
 COMPLY WITH CHAPTER 11 OF THE FLORIDA BUILDING CODE,
 BUILDING.
  
 2. SECTION 11-4.1.3(11) IF TOILET ROOMS ARE PROVIDED,
 THEN EACH PUBLIC AND COMMON USE TOILET ROOM SHALL
 COMPLY WITH SECTION 11-4.22. IF BATHING ROOMS ARE
 PROVIDED, THEN EACH PUBLIC AND COMMON USE BATHROOM
 SHALL COMPLY WITH SECTION 11-4.23. SUBMIT DETAILS FOR
 THE TOILET ROOM AND THE BATHROOM SHOWING COMPLIANCE
 WITH SECTIONS 11-4.22 & 11-4.23 WITH ALL SUBSECTIONS.
  
 3. SHT C1 GENERAL NOTES 01 INDICATES THE PROJECT WAS
 DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE
 2007 RESIDENTIAL EDITION. ALSO INDICATED ON THIS SHEET
 IS A CHANGE OF OCCUPANCY/USE FROM RESIDENTIAL TO
 BUSINESS. AS A BUSINESS OCCUPANCY, THE DESIGN SHALL BE
 IN ACCORDANCE WITH THE FLORIDA BUILDING CODE BUILDING.
  
 4. THE SINK IN THE LOUNGE SHALL BE ACCESSIBLE PER
 SECTION 906.1 AND 11-4.24. SUBMIT A DETAIL SHOWING
 COMPLIANCE WITH SECTION 11-4.24 WITH ALL SUBSECTIONS.
  
 5. SHT A-1 A DRINKING FOUNTAIN IS REQUIRED PER TABLE
 403.1. PLEASE SHOW THE LOCATION OF THE REQUIRED
 DRINKING FOUNTAIN AND SUBMIT A DETAIL SHOWING
 COMPLIANCE WITH SECTION 11-4.15 WITH ALL SUBSECTIONS AS
 WELL AS SECTION 11-4.1.3(10)(A) PROVISIONS FOR THOSE
 WHO HAVE DIFFICULTY BENDING OR STOOPING.
  
 6. SHTS A-1 & P2.01 INDICATE THE WATER SUPPLY TO THE
 SHOWER TO BE TERMINATED AND CAPPED OFF. PER SECTION
 1002.4, WHERE A TRAP SEAL IS SUBJECT TO LOSS BY
 EVAPORATION, A TRAP SEAL PRIMER VALVE SHALL BE
 INSTALLED. A TRAP SEAL PRIMER VALVE SHALL CONFORM TO
 ASSE 1018 OR ASSE 1044.
  
 7. A RZPV BACKFLOW IS REQUIRED ON THE WATER SERVICE TO
 THE BUILDING.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  

Review Stop Z ZONING
Rev No 2 Status N Date 2010-04-15 Cont ID  
Sent By aaponte Date 2010-04-15 Time 12:27 Rev Time 0.00
Received By aaponte Date 2010-04-15 Time 12:27 Sent To  
Notes
2010-04-15 12:28:33MINOR IMPROVEMENTS ONLY, ALL INTERIOR.

Review Stop Z ZONING
Rev No 1 Status P Date 2010-01-19 Cont ID  
Sent By aaponte Date 2010-01-19 Time 12:00 Rev Time 0.00
Received By aaponte Date 2010-01-19 Time 11:59 Sent To  
Notes
2010-01-19 12:00:50NO ADDITIONAL PARKING REQUIRED FOR THE OFFICE USE.
 CURRENTLY TWO PARKING SPACES WITH ACCESS FROM OLIVE
 AVENUE.