Plan Review Details - Permit 09120535
Plan Review Stops For Permit 09120535
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2010-02-09 Cont ID  
Sent By jwitmer Date 2010-02-09 Time 08:41 Rev Time 1.50
Received By jwitmer Date 2010-02-09 Time 08:41 Sent To  
Notes
2010-02-09 08:44:24BUILDING PLAN REVIEW
 PERMIT: 09120535
 ADD: 3220 45TH ST
 CONT: GARY R BROWN
 TEL: (954)214-1533
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 BUILDING PROVISO:
  
 1) ADDITIONAL INFORMATION REQUIRED: PLEASE PROVIDE
 INFORMATION ON THE HLOE CUTTING MACHINE AND EDGER AS
 WELL AS LUBRICANTS INVOLVED IN THE PROCESSING.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE
 CUSTOMER SERVICE SURVEY AT:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-12-29 Cont ID  
Sent By jwitmer Date 2009-12-29 Time 14:16 Rev Time 0.00
Received By kdfreema Date 2010-01-12 Time 13:44 Sent To  
Notes
2009-12-29 14:22:17BUILDING PLAN REVIEW
 PERMIT: 09120535
 ADD: 3220 45TH ST
 CONT: GARY R BROWN
 TEL: (954)214-1533
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
 DEC. 29/ 2009
  
 1) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER
 MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC
 BUILDING WITH 2009 SUPPLEMENTS.
  
 PLANS WILL ALSO BE REVIEWED TO THE 2007 EXISTING
 BUILDING CODE W/ 2009 SUPPLEMENTS, PLEASE INDICATE TO
 WHAT LEVEL ALTERATION WILL BE COMPLETED UNDER THIS
 PERMIT.
 401.4 A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE
 OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 403, 404 AND 405 OF THIS CODE.
 NOTE THIS IS A CHANGE OF OCCUPANCY FROM A MERCANTILE/
 WAREHOUSE TO A F2 FACTORY- INDUSTRIAL USAGE.
  
 2 ) 110.2* W. P. B. ADMINISTRATIVE CODE, INFORMATION
 THAT IS REQUIRED FOR RECORD KEEPING & FOR A NEW
 CERTIFICATE OF OCCUPANCY SINCE THERE WAS A CHANGE IN
 OCCUPANCY:
 2A) THE EDITION OF THE CODE UNDER WHICH THE PROJECT IS
 DESIGNED.
  
 2B) THE USE AND OCCUPANCY, IN ACCORDANCE WITH THE
 PROVISIONS OF CHAPTER 3.
  
 2C) THE TYPE OF CONSTRUCTION AS DEFINED IN CHAPTER5,
 TABLE 503 (ALLOWABLE HEIGHT AND AREA) .
  
 2D) THE OCCUPANT LOAD, SEE 1004.
  
 2E) IF AN AUTOMATIC SPRINKLER SYSTEM IS PROVIDED
  
 2F) WHETHER THE SPRINKLER SYSTEM IS REQUIRED ( AREA
 INCREASES)
  
 2G) ANY SPECIAL STIPULATIONS & CONDITIONS OF THE
 BUILDING PERMIT
  
 2H ) SQ. FT. FOOTPRINT OF BUILDING.
  
 3) FL EXISTING BLDG CODE 912.1.1 COMPLIANCE WITH
 CHAPTER 8. THE REQUIREMENTS OF CHAPTER 8 SHALL BE
 APPLICABLE THROUGHOUT THE BUILDING FOR THE NEW
 OCCUPANCY CLASSIFICATION BASED ON THE SEPARATION
 CONDITIONS SET FORTH IN SECTIONS 912.1.1.1 AND
 912.1.1.2.
  
 912.1.1.1 CHANGE OF OCCUPANCY CLASSIFICATION WITHOUT
 SEPARATION. WHERE A PORTION OF AN EXISTING BUILDING IS
 CHANGED TO A NEW OCCUPANCY CLASSIFICATION AND THAT
 PORTION IS NOT SEPARATED FROM THE REMAINDER OF THE
 BUILDING WITH A FIRE-RATED WALL/CEILING HAVING A
 FIRE-RESISTANCE RATING AS REQUIRED IN THE FLORIDA
 BUILDING CODE FOR THE SEPARATE OCCUPANCY, THE ENTIRE
 BUILDING SHALL COMPLY WITH ALL OF THE REQUIREMENTS OF
 CHAPTER 8 APPLIED THROUGHOUT THE BUILDING FOR THE MOST
 RESTRICTIVE OCCUPANCY CLASSIFICATION IN THE BUILDING
 AND WITH THE REQUIREMENTS OF THIS CHAPTER.
  
 912.1.1.2 CHANGE OF OCCUPANCY CLASSIFICATION WITH
 SEPARATION. WHERE A PORTION OF AN EXISTING BUILDING
 THAT IS CHANGED TO A NEW OCCUPANCY CLASSIFICATION AND
 THAT PORTION IS SEPARATED FROM THE REMAINDER OF THE
 BUILDING WITH FIRE BARRIERS HAVING A FIRE-RESISTANCE
 RATING AS REQUIRED IN THE FLORIDA BUILDING CODE FOR THE
 SEPARATE OCCUPANCY, THAT PORTION SHALL COMPLY WITH ALL
 THE REQUIREMENTS OF CHAPTER 8 FOR THE NEW OCCUPANCY
 CLASSIFICATION AND WITH THE REQUIREMENTS OF THIS
 CHAPTER.
  
 4) SHEET E2 INDICATES 12???-0??? LOUVERS OVER TOP OF
 DOORS, IS THIS EXISTING OPENINGS OR ARE THEY NEW
 OPENINGS?
  
 4A) IF NEW OPENINGS HOW IS THE MASONRY ABOVE BEING HELD
 IN PLACE? ARE THERE NEW COLUMNS?
  
 4B) IF NEW OPENINGS THEN THE LOUVERS WILL NEED PRODUCT
 APPROVALS EITHER THE FLORIDA APPROVALS OR THE
 MIAMI-DADE NOA???S ARE ACCEPTABLE, FL ADMINISTRATIVE
 CODE RULE 9B-72
 (31)( C ).
  
 4C) IF NEW OPENINGS, PLEASE PROVIDE WIND DESIGN
 CRITERIA: 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL-FORCE-RESISTING SYSTEM OF THE
 BUILDING:
 4C)1. BASIC WIND SPEED (3-SECOND GUST), MILES PER HOUR
 (KM/HR).
  
 4C)2. WIND IMPORTANCE FACTOR, I W , AND BUILDING
 CLASSIFICATION FROM TABLE 1604.5 OR TABLE 6-1, ASCE 7
 AND BUILDING CLASSIFICATION IN TABLE 1-1, ASCE 7.
  
 4C)3. WIND EXPOSURE, IF MORE THAN ONE WIND EXPOSURE IS
 UTILIZED, THE WIND EXPOSURE AND APPLICABLE WIND
 DIRECTION SHALL BE INDICATED.
  
 4C)4. THE APPLICABLE ENCLOSURE CLASSIFICATIONS AND, IF
 DESIGNING WITH ASCE 7, INTERNAL PRESSURE COEFFICIENT.
  
 4C)5. COMPONENTS AND CLADDING. THE DESIGN WIND
 PRESSURES IN TERMS OF PSF (KN/M 2 ) TO BE USED FOR THE
 SELECTION OF EXTERIOR COMPONENTS AND CLADDING MATERIALS
 NOT SPECIFICALLY DESIGNED BY THE REGISTERED DESIGN
 PROFESSIONAL.
  
 5) WILL EITHER A OVERHEAD CRANE OR CONVEYOR BE
 INSTALLED ADDING WEIGHT TO THE ROOF OR WALL REQUIRING
 ADDITIONAL LOADING AND ENGINEERING? 106.1.2. ADDITIONAL
 INFORMATION REQUIRED.
  
 6) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND
 A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
  
 A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 STARTING AUGUST 21, 2009, THE CONSTRUCTION SERVICES
 DEPARTMENT WILL BE CLOSED ON FRIDAYS UNTIL FURTHER
 NOTICE.
  
 OPENING HOURS MONDAY - THURSDAY WILL REMAIN AT 8:00 AM
 - 5:00 PM.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE
 CUSTOMER SERVICE SURVEY AT:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2010-02-11 Cont ID  
Sent By btrobaug Date 2010-02-11 Time 13:33 Rev Time 0.00
Received By btrobaug Date 2010-02-11 Time 12:15 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2010-01-04 Cont ID  
Sent By btrobaug Date 2010-01-04 Time 16:36 Rev Time 0.00
Received By btrobaug Date 2010-01-04 Time 13:17 Sent To  
Notes
2010-01-04 14:17:10 
  
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2007 FLORIDA BUILDING CODE, 2009 REVISIONS, 2008
 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND
 NONCOMPLIANT WITH THE FOLLOWING
  
 1} THE CODE ARTICLES REFERENCED ON SHEET E1 ARE
 INCORRECT, SEE ABOVE FOR THE CORRECT CODES.
  
 2} THE RISER DIAGRAM ON SHEET E3 APPEARS TO HAVE THE
 GROUNDING ELECTRODE CONDUCTOR ATTACHED TO A GROUND
 BETWEEN THE CT AND THE TRANSFORMER. 250.24(A)(1)
 GENERAL THE CONNECTION SHALL BE MADE AT ANY ACCESSIBLE
 POINT FROM THE LOAD END OF THE SERVICE DROP OR SERVICE
 LATERAL TO AND INCLUDING THE TERMINAL OR BUS TO WHICH
 THE GROUNDED SERVICE CONDUCTOR IS CONNECTED AT THE
 SERVICE DISCONNECTING MEANS.
  
 3} THE 1600 AMP MCB MUST HAVE GROUND FAULT PROTECTION
 PER 230.95 GROUND-FAULT PROTECTION OF EQUIPMENT
 GROUND-FAULT PROTECTION OF EQUIPMENT SHALL BE PROVIDED
 FOR SOLIDLY GROUNDED WYE ELECTRICAL SERVICES OF MORE
 THAN 150 VOLTS TO GROUND BUT NOT EXCEEDING 600 VOLTS
 PHASE-TO-PHASE FOR EACH SERVICE DISCONNECT RATED 1000
 AMPERES OR MORE. THE GROUNDED CONDUCTOR FOR THE SOLIDLY
 GROUNDED WYE SYSTEM SHALL BE CONNECTED DIRECTLY TO
 GROUND WITHOUT INSERTING ANY RESISTOR OR IMPEDANCE
  
 4} THE OCP AND 1/0 CONDUCTORS ARE INCORRECT FOR THE
 112.5 KVA TRANSFORMER. SEE 450.5(A)(2) (125%). ALSO
 THERE ARE 4 CONDUCTORS LISTED AT THAT SIZE WHEN THERE
 SHOULD ONLY BE THREE AND A GROUNDING CONDUCTOR.
  
 5} THE ELECTRICAL CONTRACTOR NEEDS TO SIGN THE PERMIT
 APPLICATION UNDER "CONTRACTOR SIGNATURE PORTION ON THE
 BACK OF THE PERMIT.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW.
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-02-03 Cont ID  
Sent By btrobaug Date 2010-02-03 Time 12:17 Rev Time 0.00
Received By btrobaug Date 2010-02-03 Time 12:16 Sent To  
Notes
2010-02-11 12:18:12B-10

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-01-13 Cont ID  
Sent By shill Date 2010-01-13 Time 10:12 Rev Time 0.00
Received By shill Date 2009-12-29 Time 09:34 Sent To  
Notes
2009-12-29 09:34:31B 2

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2010-02-17 Cont ID  
Sent By rregueir Date 2010-02-17 Time 08:11 Rev Time 0.00
Received By rregueir Date 2010-02-17 Time 08:11 Sent To  
Notes
2010-02-17 08:12:39SEPARATE MECHANICAL PERMIT WITH PLANS AND WIND
 RESISTANT INSTALLATION DETAIL REQUIRED.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2010-01-11 Cont ID  
Sent By rregueir Date 2010-01-11 Time 14:37 Rev Time 0.00
Received By rregueir Date 2010-01-11 Time 14:25 Sent To  
Notes
2010-01-11 14:37:19REVIEW #: 1ST
 ACTION: DENIED
  
 FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENTS
 FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH
  
 1. NO INFORMATION WAS PROVIDED REGARDING THE PROPOSED
 OVEN/FURNACE. PROVIDE MANUFACTURER'S SUBMITTAL DATA AND
 INSTALLATION INSTRUCTIONS PER FBC-M 304.1.
  
 2. NO INFORMATION WAS PROVIDED REGARDING THE PROPOSED
 EXHAUST DUCTWORK. PROVIDE TYPE AND SIZE OF DUCT TO BE
 USED IN ACCORDANCE WITH FBC-M 501.1.
  
 3. PLANS APPEAR TO INDICATE EXHAUST FANS AND DUCTWORK
 BEING INSTALLED OUTDOORS. FANS AND DUCT SHALL BE
 DESIGNED AND INSTALLED FOR WIND RESISTANCE IN
 ACCORDANCE WITH FBC-M 301.12. PROVIDE MANUFACTURER'S
 DATA FOR THE WIND RESISTANCE CHARACTERISTICS OF THE
 FANS AND WIND RESISTANT INSTALLATION DETAILS FOR THE
 FANS AND THE DUCTWORK.
  
 4. PLANS SHOW LOUVERS ON THE SOUTH WALL OF THE
 BUILDING. ARE THESE LOUVERS NEW OR EXISTING? PLEASE
 INDICATE ON THE PLANS WHAT IS NEW AND WHAT IS EXISTING
 TO DEMONSTRATE THE EXACT SCOPE OF WORK PER FBC-B 106.1.
  
 5. IF LOUVERS ARE NEW, PROVIDE PRODUCT APPROVALS FOR
 LOUVERS AS REQUIRED PER FBC-B 106.3.3 AND FAC RULE
 9B-72.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop Z ZONING
Rev No 2 Status P Date 2010-02-03 Cont ID  
Sent By kdfreema Date 2010-02-03 Time 16:28 Rev Time 0.00
Received By kdfreema Date 2010-02-03 Time 16:27 Sent To  
Notes
2010-02-03 16:28:59***PROVISO***
  
 THE PERMITS FOR THE CARPORT STRUCTURE AND FENCE SHALL
 BE FINALED PRIOR TO THE ISSUANCE OF A FINAL ON THIS
 PERMIT.
  
 PLEASE CONTACT KELLY FREEMAN, GIS PLANNER, AT
 561-822-1458 WITH QUESTIONS.

Review Stop Z ZONING
Rev No 1 Status F Date 2010-01-12 Cont ID  
Sent By kdfreema Date 2010-01-12 Time 13:45 Rev Time 0.00
Received By kdfreema Date 2010-01-12 Time 13:45 Sent To  
Notes
2010-01-12 13:55:42***FAILED***
  
 PLEASE PROVIDE DETAILS ON HOW THE PROPOSED OUTDOOR
 BLOWER UNITS ARE TO BE SCREENED. NOTE THAT ANY WALLS
 USED SHOULD BE OF SUFFICIENT HEIGHT TO SCREEN THE
 EQUIPMENT FULLY.
  
 PLEASE PROVIDE DIMENSIONAL INFORMATION RELATING TO THE
 SIZE OF THE BLOWERS.
  
 PLEASE PROVIDE INFORMATION REGARDING THE DISTANCE
 BETWEEN THE PROPOSED EQUIPMENT AND/OR ENCLOSURE AND THE
 EAST, SOUTH, AND WEST PROPERTY LINES.
  
 PLEASE CONTACT KELLY FREEMAN, GIS PLANNER, AT
 561-822-1458 OR [email protected] WITH QUESTIONS.