Plan Review Details - Permit 09120471
Plan Review Stops For Permit 09120471
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2010-04-09 Cont ID  
Sent By lmartine Date 2010-04-09 Time 14:27 Rev Time 0.00
Received By lmartine Date 2010-04-09 Time 14:27 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2010-01-07 Cont ID  
Sent By shill Date 2010-01-07 Time 13:12 Rev Time 0.00
Received By shill Date 2010-01-07 Time 13:12 Sent To  
Notes
2010-01-07 13:13:15****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007
 FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1. PROVIDE A SPECIFICATION FOR THE CONCRETE (STRENGTH,
 REINFORCEMENT).
  
 2. REVISE SITE PLAN TO SHOW LOCATION RELATIVE TO
 STRUCTURES AND/OR PROPERTY LINE.
  

Review Stop ENG ENGINEERING CSD
Rev No 3 Status P Date 2010-04-08 Cont ID  
Sent By dlauderm Date 2010-04-08 Time 13:54 Rev Time 1.00
Received By dlauderm Date 2010-04-08 Time 13:54 Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2010-03-25 Cont ID  
Sent By mgonzale Date 2010-03-25 Time 13:38 Rev Time 1.00
Received By mgonzale Date 2010-03-25 Time 13:38 Sent To  
Notes
2010-03-25 13:39:32PASSED WITH PROVISO
  
 OWNER/OWNER REP WILL SECURE A ROW PERMIT FOR DRIVEWAY
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2010-01-05 Cont ID  
Sent By mgonzale Date 2010-01-05 Time 11:50 Rev Time 0.50
Received By mgonzale Date 2010-01-05 Time 11:50 Sent To  
Notes
2010-01-05 11:56:36COMMENTS:
  
 #1 (1) CONCRETE APRON APPROACH MUST BE PERMITTED THRU
 ESD (ENGINEERING SERVICES DEPT) UNDER A ROW PERMIT
 PLEASE SEE LINK BELOW.
 HTTP://WWW.CITYOFWPB.COM/ENGINEERING/UPLOADS/2009-06-04
 -14-16-04-CWPBRIGHT-OF-WAYPERMITPACKAGE.PDF
 ANY QUESTIONS SHOULD BE DIRECTED TO:
 WINDEL G PALMER, UTILITIES ENGINEERING PROJECT
 COORDINATOR
 TRAFFIC DIVISION, 401 CLEMATIS STREET, WEST PALM BEACH,
 FL 33401, PHONE: 494-1040 EXT: 1086, FAX: 494-1069,
 E-MAIL: [email protected]
  
 #2 APRON MUST BE THREE FEET MINIMUM FROM CLOSEST
 PROPERTY LINE.
  
 #3 SHOW WIDTH DIMENSIONS TO NEW DRIVEWAY APPRON.
  
 #4 MUST BE 6" THICK CONCRETE IN THE ROW.
  
 MANUEL JULIAN GONZALEZ
 ENGINEERING PROJECT COORDINATOR
 ENGINEERING SERVICES DEPARTMENT
 401 CLEMATIS STREET, 4TH FLOOR
 WEST PALM BEACH, FL 33401
 (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402)
 MAIN PHONE: (561) 822-1200
 DIRECT: (561) 494-1085
 FAX: (561) 494-1116
 MOBILE: (561) 644-7301
 EMAIL: [email protected]
 WWW.WPB.ORG/ENGINEERING
  
  
  
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2009-12-23 Cont ID  
Sent By mmiller Date 2009-12-23 Time 11:35 Rev Time 0.00
Received By mmiller Date 2009-12-23 Time 11:35 Sent To  
Notes
2009-12-23 11:35:36OK PER HISTORIC PLANNER MMILLER

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-03-22 Cont ID  
Sent By lmartine Date 2010-03-18 Time 14:04 Rev Time 0.00
Received By lmartine Date 2010-03-18 Time 14:04 Sent To  
Notes
2010-03-22 14:08:07SENT TO ZONING

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2010-01-07 Cont ID  
Sent By shill Date 2010-01-07 Time 13:13 Rev Time 0.00
Received By shill Date 2010-01-05 Time 14:13 Sent To  
Notes
2010-01-05 14:14:05MISC #3
  
2009-12-23 15:35:35SENT TO ZONING BOX.

Review Stop Z ZONING
Rev No 2 Status P Date 2010-03-29 Cont ID  
Sent By jroach Date 2010-03-29 Time 13:43 Rev Time 0.00
Received By jroach Date 2010-03-29 Time 13:43 Sent To ENG
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2009-12-30 Cont ID  
Sent By jroach Date 2009-12-30 Time 13:55 Rev Time 0.00
Received By jroach Date 2009-12-30 Time 13:55 Sent To ENG
Notes
2009-12-30 13:55:31ZONING PLAN REVIEW
  
 PERMIT NO.: 09120471
 ADDRESS: 624 BISCAYNE DRIVE
 CONTRACTOR/CONTACT: LILA CORNELL
 TELEPHONE NO.: 561.370.3886
 SCOPE OF REVIEW: DRIVEWAY
  
 REVIEW STATUS: FAILED
  
 PLEASE PROVIDE A WRITTEN RESPONSE TO THE FOLLOWING PLAN
 REVIEW COMMENTS:
  
 1) PURSUANT TO SECTION 94-313(1) OF THE CITY???S ZONING
 AND LAND DEVELOPMENT REGULATIONS (ZLDRS), SINGLE FAMILY
 RESIDENTIAL HOMES ARE ONLY PERMITTED ONE (1) ACCESS
 POINT (I.E. CURB-CUT). AS PROPOSED, THE DRIVEWAY SHOWS
 TWO (2) CURB-CUTS. PLEASE REVISE THE PLANS ACCORDINGLY.
  
 2) PURSUANT TO SECTION 94-482(A) OF THE CITY???S ZLDRS,
 75 PERCENT OR 1,000 SQUARE FEET OF THE FRONT YARD,
 WHICHEVER IS LESS, SHALL BE MAINTAINED AS LANDSCAPING.
 ACCORDING TO THE PROPOSED PLANS, INSUFFICIENT
 LANDSCAPING IS PROVIDED IN THE FRONT YARD.
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN ROACH, SENIOR PLANNER
 CITY OF WEST PALM BEACH
 PLANNING AND ZONING DEPARTMENT
 401 CLEMATIS STREET - P.O. BOX 3366
 WEST PALM BEACH, FLORIDA 33402
  
 PHONE: 561.822.1435
 FAX: 561.822.1460
  
 EMAIL: [email protected]
  
 WWW.CITYOFWPB.COM
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved