Plan Review Details - Permit 09120254
Plan Review Stops For Permit 09120254
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2009-12-17 Cont ID  
Sent By shill Date 2009-12-17 Time 11:15 Rev Time 0.00
Received By shill Date 2009-12-17 Time 11:00 Sent To  
Notes
2009-12-17 11:13:48****PROVISO****
 ****ISSUED AT CONTRACTOR'S RISK****
 ****REVISION REQUIRED PRIOR TO FIRST INSPECTION****
 ****ALL EXIT DOORS ARE SPECIFICALLY EXCLUDED FROM THIS
 PERMIT UNTIL THE PROVISO HAS BEEN ADDRESSED****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. FBC 1003.6, MEANS OF EGRESS CONTINUITY. THE PATH OF
 EGRESS TRAVEL ALONG A MEANS OF EGRESS SHALL NOT BE
 INTERRUPTED BY ANY BUILDING ELEMENT OTHER THAN A MEANS
 OF EGRESS COMPONENT AS SPECIFIED IN THIS CHAPTER.
 OBSTRUCTIONS SHALL NOT BE PLACED IN THE REQUIRED WIDTH
 OF A MEANS OF EGRESS EXCEPT PROJECTIONS PERMITTED BY
 THIS CHAPTER.
  
 1008.1.3.5 SECURITY GRILLS. IN GROUPS B, F, M, R AND S,
 HORIZONTAL SLIDING OR VERTICAL SECURITY GRILLES ARE
 PERMITTED AT THE MAIN EXIT AND SHALL BE OPENABLE FROM
 THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL
 KNOWLEDGE OR EFFORT DURING PERIODS THAT THE SPACE IS
 OCCUPIED. THE GRILLES SHALL REMAIN SECURED IN THE
 FULL-OPEN POSITION DURING THE PERIOD OF OCCUPANCY BY
 THE GENERAL PUBLIC. WHERE TWO OR MORE MEANS OF EGRESS
 ARE REQUIRED, NOT MORE THAN ONE-HALF OF THE EXITS OR
 EXIT ACCESS DOORWAYS SHALL BE EQUIPPED WITH HORIZONTAL
 SLIDING OR VERTICAL SECURITY GRILLES.
  
 PROVIDE A LEGIBLE FLOOR PLAN SHOWING COMPLIANCE WITH
 FBC1003.6, FBC1008.1.3.5. INCLUDE INFORMATION SUCH AS
 OCCUPANCY CLASSIFICATION, DOOR SWING FOR EXIT DOORS,
 ETC. (ANY INFORMATION REQUIRED TO SHOW COMPLIANCE WITH
 FBC1008.1.3.5). NOTE THAT THERE IS NO PROVISION IN THE
 CODE TO BLOCK REQUIRED EXITS FOR THE PURPOSE OF IMPACT
 PROTECTION.
  
 FOR THE ROLLUP SHUTTERS PROPOSED OVER EXIT DOORS, SHOW
 HOW SOMEONE WITH NO "SPECIAL KNOWLEDGE OR EFFORT" WILL
 KNOW HOW TO OPERATE THE SHUTTERS (SIGNAGE, ETC.).
  
 2. COMPLETE THE SAMPLE INSTALLATION SCHEDULE OR PROVIDE
 ALL INFORMATION TO SHOW CODE COMPLIANCE IN ANOTHER
 FORMAT, FBC*106, FBC R301, FBC1609. TWO SETS REQUIRED.
 THIS FORM IS AVAILABLE IN THE LOBBY OR ON THE INTERNET
 AT
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDULE_FOR_
 INSTALLATION.PDF
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-12-17 Cont ID  
Sent By shill Date 2009-12-17 Time 11:15 Rev Time 0.00
Received By shill Date 2009-12-14 Time 14:25 Sent To B
Notes
2009-12-14 14:25:37MISC #1


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved