Plan Review Details - Permit 09110358
| Plan Review Stops For Permit 09110358 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2010-05-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-05-24 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-05-24 |
Time |
16:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2010-05-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-05-18 |
Time |
17:52 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-05-18 |
Time |
17:52 |
Sent To |
|
|
| Notes |
| 2010-05-18 17:56:00 | ****CORRECTIONS**** | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | | | | 1. AS DISCUSSED, PLEASE SPECIFY CONNECTORS, TOP AND | | | BOTTOM. A SIMPSON PRODUCT APPROVAL FOR 22 DIFFERENT | | | CONNECTORS WAS INCLUDED, BUT THE PLAN DOES NOT SPECIFY | | | WHICH CONNECTOR IS PROPOSED. THE PLAN STATES THAT A | | | SIMPSON POST BASE WAS USED AT THE BOTTOM, BUT THE | | | PRODUCT APPROVAL SUBMITTED DOES NOT APPEAR TO INCLUDE A | | | POST BASE. PLEASE REVISE THE DETAIL TO INCLUDE THE | | | SPECIFIC PRODUCTS USED AND PROVIDE PRODUCT APPROVAL FOR | | | THOSE PRODUCTS. | | | | | | PER JON VANDERBER'S EMAIL TO YANI - " . . . WE NEED TO | | | SKETCH A LITTLE DIAGRAM OF THE 4 X 4 WITH THE WIND | | | LOADS OF THE BRACKETS." WITHOUT THE BRACKET (CONNECTOR) | | | INFORMATION, I CANNOT DETERMINE THAT THE CONNECTOR | | | PROPOSED IS APPROVED BY THE MANUFACTURER/PRODUCT | | | APPROVAL FOR THE APPLICATION PROPOSED, AND WIND UPLIFT | | | INFORMATION IS SPECIFIC TO EACH CONNECTOR. | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2009-11-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-11-30 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-11-30 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2009-11-30 11:08:27 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | 1. DECLARE WIND DESIGN CRITERIA FBC R 301.2. | | | | | | 2. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED FOR | | | CONNECTORS, FAC9B72. SPECIFY CONNECTORS TO BE USED, TOP | | | AND BOTTOM, AND PROVIDE PRODUCT APPROVAL. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
|
Date |
2009-11-23 |
|
|
Cont ID |
|
| Sent By |
tmoore |
Date |
2009-11-23 |
Time |
10:22 |
Rev Time |
0.00 |
| Received By |
tmoore |
Date |
2009-11-23 |
Time |
10:09 |
Sent To |
|
|
| Notes |
| 2009-11-23 10:22:30 | SPOKE TO CONTRACTOR. DETAILS OF SIZE AND TYPE OF MEMBER | | | AND CONNECTION NEEDED TO BE ADDED TO APPLICATION. | | | THIS IS A REPAIR, REPLACEMENT OF MEMBERS. NO NEW | | | CONSTRUCTION. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2010-05-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-05-13 |
Time |
08:25 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-05-13 |
Time |
08:25 |
Sent To |
|
|
| Notes |
| 2010-05-13 08:25:49 | TO S HILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
|
Date |
2009-11-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-11-23 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-11-23 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2009-11-24 16:31:56 | REMOVE FROM SAMANTHA | | | FILED UNDER 5K, BUILDING | | 2009-11-24 16:11:53 | GAVE TO SAMANTHA |
|
|
|