Plan Review Details - Permit 09110285
Plan Review Stops For Permit 09110285
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2010-02-11 Cont ID  
Sent By jwitmer Date 2010-02-11 Time 08:36 Rev Time 0.50
Received By jwitmer Date 2010-02-11 Time 08:36 Sent To  
Notes
2010-02-11 08:37:37BROUGHT IN THE MISSING D1.1 & S1.02

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2010-02-02 Cont ID  
Sent By jwitmer Date 2010-02-02 Time 10:30 Rev Time 2.50
Received By jwitmer Date 2010-02-02 Time 08:02 Sent To  
Notes
2010-02-02 11:45:55 
 BUILDING PLAN REVIEW
 PERMIT: 09110285
 ADD: 4812 S DIXIE HWY
 CONT: ALL CRETE CONSTRUCTION
 TEL: (561)704-5047
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 FEB. 02/2010
 3RD REVIEW
 ACTION: DENIED
  
 BUILDING STARTED TO PASS THE PLANS, THERE ARE THREE
 SETS OF PLANS PLEASE THE SEE PLANS ARE OF DIFFERENT
 DATES, VERSION# 1 & VERSION# 2 & VERSION # 3.
 106.3.1 REQUIRES TWO SETS OF IDENTICAL PLANS ONE SET TO
 BE RETAINED FOR RECORD RETENSION, THE OTHER SET SHALL
 BE RETURNED TO THE APPLICANT, SHALL BE KEPT AT THE SITE
 OF WORK AND SHALL BE OPEN TO INSPECTION BY THE BUILDING
 OFFICIAL OR A DULY AUTHORIZED REPRESENTATIVE. THE PLANS
 DO NOT MATCH.
  
 SET# 1 SET# 2 SET# 3
 DATE OF PLANS DATE OF PLAN DATE OF PLAN
 1/25/10 12/14/09 11/11/09
 D1.01 MISSING MISSING
 A1.01 A1.01 A1.01 MARKED VOID
 A1.02 A1.02 A1.02 MARKED VOID
 S1.01 S1.01 S1.01 MISSING
 S1.02 SAME DETAIL AS SET 3 NELSON STUD & A 4'-0" S1.02
 (2) 3/4 HILTI BOLTS S1.02 MARKED VOID
 LONG Z-BAR THAT DOESN'T SPAN THE ENTIRE LENGTH OF THE
 OPENING NOR DOES THE Z-BAR RISE TO THE TOP STEEL IT
 RISES ONLY TO THE MID- POINT OF THE BEAM! THIS VERSION
 IS
 DIFFERENT FROM SET# 2 WITH THE (2) 3/4" HILTI EXPANSION
 BOLTS!
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE
 CUSTOMER SERVICE SURVEY AT:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2010-01-06 Cont ID  
Sent By jwitmer Date 2010-02-02 Time 10:00 Rev Time 0.50
Received By jwitmer Date 2009-12-28 Time 14:57 Sent To  
Notes
2009-12-28 14:58:55AWAITING RETURN CALL FROM ARCHITECT OSCAR BENITEZ
 (305)785-3300. 12/28/09 2:55 PM.
  
 12/29/09 SPOKE WITH OSCAR BENITEZ ABOUT Z-BAR TYPE
 BEAM, HE IS GOING TO REISSUE THIS DETAIL, NEW SHEET.
  
 01-06-10PLANS FAIL THE NEWS1.02 DETAIL D HAS EMBEDS AND
 Z-BAR LOCATED WITHIN THE EXISTING BEAM, THE BEAM WOULD
 NEED TO BE REMOVED TO PLACE THESE ITEMS IN THE BEAM.
 WHEN I SPOKE WITH THE ARCHITECT, THIS WAS NOT THE
 ENTENT, THE PLANS INDICATE EXISTING BEAM, TO DATE NO
 NEW PLANS WERE SUBMITTED TO CORRECT THIS ISSUE TO DATE.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE
 CUSTOMER SERVICE SURVEY AT:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-11-20 Cont ID  
Sent By jwitmer Date 2009-11-20 Time 08:59 Rev Time 2.10
Received By jwitmer Date 2009-11-19 Time 07:02 Sent To  
Notes
2009-11-20 08:57:06BUILDING PLAN REVIEW
 PERMIT: 09110285
 ADD: 4812 S DIXIE HWY
 CONT: ALL CRETE CONSTRUCTION
 TEL: (561)704-5047
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 NOV19-20/ 2009
 1ST REVIEW
 ACTION: DENIED
  
 1) BOTH THE PERMIT APPLICATION AAND PLANS INDICATE THE
 PARKING LOT IS TO BE RE-STRIPED. G1.01 THE SITE PLAN
 DOES NOT PROVIDE DIMENSIONS TO THE STANDARD PARKING
 SPACES NOR THE ACCESSIBLE PARKING SPACE OR THE ACCESS
 AISLE AND ACCESSIBLE ROUTE, PLEASE PROVIDE DETAIL IN
 ACCORDANCE WITH SECTION 11-46.2, (1), 11-4.6.3,
 11-4.6.4 & 11-4.3.2(1). ALSO SEE FIGURE 9(A).
  
 2) PLANS (G1.01) ALSO INDICATE IN SCOPE OF WORK NOTE# 2
 THE REMOVAL AND REPLACEMENT OF KITCHEN CABINETS AND
 APPLIANCES, PLEASE PROVIDE UPDATE AS TO THE LOCATION OF
 KITCHEN, NOT SHOWN ON PLAN. IF THE TERM KITCHEN REFERS
 TO THE EXISTING BAR THEN PROVIDE COMPLIANCE WITH
 SECTION 11-5.2 .
  
 3A) SHEET G1.01 INDICATES THE SCOPE OF WORK LIMITED TO
 6 ITEMS, WHERE AS WHEN SPEAKING WITH CHIEF ELECTRICAL
 INSPECTOR JAKE LEAHY THE INTERIOR OF THE BUILDING THE
 SCOPE OF WORK HAS EXCEEDED THE DESCRIPTION OF WORK,
 PLEASE PROVIDE EXPLANATION. 106.1.2 ADDITIONAL
 INFORMATION REQUIRED.
  
 3B) THE CONTRACT VALUE OF WORK LISTED ON THE PERMIT
 APPLICATION IS LOW,, PLUS THE DECREPANCY OF WORK.
 PLEASE UPDATE THE VALUE TO THE TRUE REFLECTION OF WORK
 AND ASSOCIATED FEES TO BE REFLECTED WITHIN THE PERMIT.
 W P B ADMINISTRTIVE CODE 108.2 SCHEDULE OF PERMIT FEES.
 ON BUILDINGS, STRUCTURES, ELECTRICAL, GAS, MECHANICAL,
 AND PLUMBING SYSTEMS OR ALTERATIONS REQUIRING A PERMIT,
 A FEE FOR EACH PERMIT SHALL BE PAID AS REQUIRED, IN
 ACCORDANCE WITH THE SCHEDULE ESTABLISHED BY THE
 APPLICABLE GOVERNING AUTHORITY.
  
 108.3* BUILDING PERMIT VALUATION.
 IF, IN THE OPINION OF THE BUILDING OFFICIAL, THE
 CLAIMED VALUATION OF BUILDING, ALTERATION, STRUCTURE,
 ELECTRICAL, GAS, MECHANICAL, OR PLUMBING SYSTEMS
 APPEARS TO BE UNDER ESTIMATED ON THE APPLICATION, THE
 PERMIT SHALL BE DENIED. FOR PERMITTING PURPOSES,
 VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL
 REPLACEMENT PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT VALUE TO INCLUDE
 STRUCTURAL, ELECTRICAL, PLUMBING, MECHANICAL, INTERIOR
 FINISHES, NORMAL SITE WORK (EXCAVATION AND BACKFILL FOR
 BUILDINGS), ARCHITECTURAL AND DESIGN FEES, MARKETING
 COST, OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFRENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES
 (MARSHALL-SWIFT, MEANS, ETC) WITH REGIONAL ADJUSTMENTS
 FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE
 CONGRESS.
  
 4) THE PLANS SHEET A1.01 & A1.02 BOTH INDICATE ON THE
 SOUTH ELEVATION NEW GLAZED DOOR AND WINDOW OPENINGS:
 4A) SHEET A1.02 DOES INDICATE TO GROUT CELLS BELOW THE
 WINDOW @ 48 INCHES ON CENTER BUT NO MENTION AS TO WHAT
 TO DO WITH THE WINDOW SILL? 1604.9 CONTINOUS LOAD
 PATHS, TO PREVENT OVERTURNING, SLIDING AND UPLIFT.
  
 4B) THE PRODUCT APPROVALS SUBMITTED DO NOT HAVE LARGE
 MISSILE TESTING REQUIRING EITHER STORM SHUTTERS OR
 STORM PANELS PLEASE PROVIDE PRODUCT APPROVALS.
 1609.1.4 PROTECTION OF OPENINGS IN WIND-BORNE DEBRIS
 REGIONS, EXTERIOR GLAZING THAT RECEIVES POSITIVE
 PRESSURE IN THE LOWER 60 FEET (18.3 M) IN BUILDINGS
 SHALL BE ASSUMED TO BE OPENINGS AND THE BALANCE OF
 GLAZED OPENINGS IN THE REST OF THE BUILDING SHALL BE
 ASSUMED TO BE ZERO UNLESS SUCH GLAZING THAT RECEIVES
 POSITIVE PRESSURE IS IMPACT RESISTANT OR PROTECTED WITH
 AN IMPACT RESISTANT COVERING MEETING THE REQUIREMENTS
 OF SSTD 12, ASTM E 1886 AND ASTM E 1996, OR MIAMI-DADE
 TAS 201, 202 AND 203 REFERENCED THEREIN AS FOLLOWS: 1.
 GLAZED OPENINGS LOCATED WITHIN 30 FEET (9.1 M) OF GRADE
 SHALL MEET THE REQUIREMENTS OF THE LARGE MISSILE TEST.
 2. GLAZED OPENINGS LOCATED MORE THAN 30 FEET (9.1 M)
 ABOVE GRADE SHALL MEET THE PROVISIONS OF THE SMALL
 MISSILE TEST.
  
 4C) PROVIDE STORM PANEL INFORMATION WITH INSTALLATION
 SCHEDULE AND KEY PLAN WITH SPECIFIC ANCHORS AND
 MOUNTING TO BE USED FOR ALL NON-IMPACT GLAZING. FBC
 1609.1.4.
  
 FL BLD CODE 2004 SECTION 106.3.3, 1609.1.4, 1714.5.1 &
 EXIST BUILD CODE 507.3. PROCEDURES: 1(B) A COMPLETE
 INSTALLATION SCHEDULE SUMMARIZING & IDENTIFYING OPENING
 SIZES, STORY HEIGHTS, UNIT MARK NUMBERS, UNIT
 SPANS/WIDTHS, UNIT STORM BAR REINFORCING REQUIREMENTS,
 WALL PRESSURE ZONES, SLAT TYPES, ETC., SHALL BE
 SUBMITTED AT TIME OF PERMIT APPLICATION TO FACILITATE
 PLAN REVIEW AND PERMIT ISSUANCE. PLEASE SEE ATTACHED
 SAMPLE.
  
 A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH
 A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE
 SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE
 FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR
 YOUR ANTICIPATED COOPERATION.
  
 STARTING AUGUST 21, 2009, THE CONSTRUCTION SERVICES
 DEPARTMENT WILL BE CLOSED ON FRIDAYS UNTIL FURTHER
 NOTICE.
  
 OPENING HOURS MONDAY - THURSDAY WILL REMAIN AT 8:00 AM
 - 5:00 PM.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
  
 PLEASE TAKE A MOMENT TO COMPLETE OUR ANONYMOUS ON-LINE
 CUSTOMER SERVICE SURVEY AT:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2010-02-11 Cont ID  
Sent By btrobaug Date 2010-02-11 Time 14:13 Rev Time 0.00
Received By btrobaug Date 2010-02-11 Time 14:13 Sent To  
Notes
2010-02-11 14:31:17PROVISO
  
 IF NEW LIGHING IS INSTALLED OR EXISYING LIGHTING
 EXTENDED IT MUST COMPLY WITH 13-415 AND A REVISION
 SHALL BE SUBMITTED INDICATNG COMPLIANCE AND LOCATION OF
 FIXTURES AND OCCUPANCY SENSORS.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2009-11-18 Cont ID  
Sent By btrobaug Date 2009-11-18 Time 12:57 Rev Time 0.00
Received By btrobaug Date 2009-11-18 Time 07:06 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2010-02-11 Cont ID  
Sent By mawillia Date 2010-02-11 Time 13:13 Rev Time 0.00
Received By mawillia Date 2010-02-11 Time 12:55 Sent To  
Notes
2010-02-11 13:13:34*****APPROVED*****
  
 THE CPMMENTS FROM THE PREVIOUS PLAN REVIEW HAVE BEEN
 ADDRESSED; PLAN SHEETS A1.01, A1.02, AND E1.01 WERE
 STAMPED, INITIALED, AND DATED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2010-01-14 Cont ID  
Sent By mawillia Date 2010-01-14 Time 13:19 Rev Time 0.00
Received By mawillia Date 2010-01-14 Time 12:47 Sent To  
Notes
2010-01-14 13:19:06*****DENIED*****
  
  
 THE FOLLOWING COMMENTS TAKEN FROM THE PREVIOUS PLAN
 REVIEW HAVE NOT BEEN ADDRESSED:
  
 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY
 SHALL COMPLY WITH NFPA 241 - 2004 EDITION.
  
 2. DEBRIS FROM DEMOLITION SHALL BE REMOVED FROM THE
 SITE DAILY.
  
 3. THE ELEVATION DRAWINGS DO NOT REVEAL THE BUILDING
 ADDRESS. THE ADDRESS NUMBERS SHALL BE A MINIMUM OF AT
 LEAST 6" IN HEIGHT AND AT LEAST 1" IN WIDTH. THESE
 NUMBERS SHOULD CONTRAST TO THE BACKGROUND THAT THEY ARE
 AFFIXED.
  
 4. PLEASE ENSURE THAT ALL EXISTING EMERGENCY LIGHTS AND
 EXITS SIGNS ARE IN WORKING CONDITION.
  
 5. SPECIFY THE INTERIOR FINISH CLASSIFICATIONS FOR
 WALLS AND CEILINGS IN TERMS OF CLASS A, CLASS B, OR
 CLASS C.
  
 6. PLEASE INDICATE PORTABLE FIRE EXTINGUISHER
 LOCATIONS.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE
 LETTER INDICATING WHERE EACH ITEM WAS ADDRESSED ON THE
 PLANS
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2009-12-04 Cont ID  
Sent By mcarsill Date 2009-12-04 Time 08:31 Rev Time 0.00
Received By mcarsill Date 2009-12-04 Time 07:43 Sent To  
Notes
2009-12-04 08:31:51 
 1. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY
 WITH NFPA 241.
  
 2. DEBRIS FROM DEMOLITION SHALL BE REMOVED FROM THE
 SITE DAILY.
  
 3. THE ELEVATION DRAWINGS DO NOT REVEAL THE BUILDING
 ADDRESS. THE BUILDING ADDRESS SHALL BE A MINIMUM OF AT
 LEAST 6" HIGH AND AT LEAST 1" WIDE. THESE NUMBER SHOULD
 CONTRAST TO THE BACKGROUND THAT THEY ARE AFFIXED TO.
  
 4. PLEASE ENSURE THAT ALL EXISTING EMERGENCY LIGHTS AND
 EXIT SIGNS ARE IN PROPER WORKING CONDITION.
  
 5. PLEASE INDICATE INTERIOR FINISH CLASSIFICATIONS FOR
 WALLS AND CEILINGS.
  
 6. PLEASE INDICATE PORTABLE FIRE EXTINGUISHER
 LOCATIONS.
  
 DENIED
  
 MIKE CARSILLO, BATTALION CHIEF
 BUREAU OF FIRE PREVENTION
 (561) 804-4709 PHONE
 (561) 804-4775 FAX

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2010-01-27 Cont ID  
Sent By lmartine Date 2010-01-26 Time 11:15 Rev Time 0.00
Received By lmartine Date 2010-01-26 Time 11:15 Sent To  
Notes
2010-01-27 11:31:01C--16

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-12-23 Cont ID  
Sent By jgomez Date 2009-12-23 Time 15:44 Rev Time 0.00
Received By jgomez Date 2009-12-23 Time 15:44 Sent To  
Notes
2009-12-23 15:46:33SENT TO C7.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-12-22 Cont ID  
Sent By lmartine Date 2009-12-04 Time 12:51 Rev Time 0.00
Received By lmartine Date 2009-11-17 Time 13:31 Sent To  
Notes
2009-11-17 13:33:54C-36

Review Stop P PLUMBING
Rev No 3 Status P Date 2010-02-01 Cont ID  
Sent By kstevens Date 2010-02-01 Time 13:11 Rev Time 0.00
Received By kstevens Date 2010-02-01 Time 13:11 Sent To  
Notes
2010-02-01 13:12:15 
  
  
  
  
  
 PASSED/PROVISO:
  
 SHT P1.01 SANITARY RISER DIAGRAM DOES NOT REFLECT THE
 FLOOR PLAN, NOR DOES IT MEET CODE REQUIREMENTS. THE
 FLOOR PLAN SHOWS ONE BLDG DRAIN WITH A DOUBLE WYE
 PICKING UP BOTH TOILET ROOMS. BUT THE RISER SHOWS BOTH
 TOILET ROOMS EXITING THE BUILDING SEPARATELY. -- THE
 TRAPS FOR THE W/C'S ARE NOT APPROVED AS THE W/C'S HAVE
 INTEGRAL TRAPS AND DOUBLE TRAPING IS NOT APPROVED PER
 SECTION 1002.1. -- THE TRAPS FOR THE LAVS ARE INDICATED
 AS UNDER THE SLAB ON THE RISER DIAGRAM.
  
 SHT P1.01 THE WATER RISER DIAGRAM DOES NOT SHOW THE
 WATER SUPPLY TO EITHER W/C.
  
 A REVISION IS REQUIRED TO CORRECT THESE DIFICENCIES AND
 REFLECT THE INSTALLATION.
  
  
  
  
  
 .

Review Stop P PLUMBING
Rev No 2 Status F Date 2010-01-14 Cont ID  
Sent By kstevens Date 2010-01-06 Time 16:43 Rev Time 0.00
Received By kstevens Date 2010-01-06 Time 16:43 Sent To  
Notes
2010-01-06 16:51:28 
  
 PASSED/PROVISO:
  
 SHT P1.01 SANITARY RISER DIAGRAM DOES NOT REFLECT THE
 FLOOR PLAN, NOR DOES IT MEET CODE REQUIREMENTS. THE
 FLOOR PLAN SHOWS ONE BLDG DRAIN WITH A DOUBLE WYE
 PICKING UP BOTH TOILET ROOMS. BUT THE RISER SHOWS BOTH
 TOILET ROOMS EXITING THE BUILDING SEPARATELY. -- THE
 TRAPS FOR THE W/C'S ARE NOT APPROVED AS THE W/C'S HAVE
 INTEGRAL TRAPS AND DOUBLE TRAPING IS NOT APPROVED PER
 SECTION 1002.1. -- THE TRAPS FOR THE LAVS ARE INDICATED
 AS UNDER THE SLAB ON THE RISER DIAGRAM.
  
 SHT P1.01 THE WATER RISER DIAGRAM DOES NOT SHOW THE
 WATER SUPPLY TO EITHER W/C.
  
 A REVISION IS REQUIRED TO CORRECT THESE DIFICENCIES AND
 REFLECT THE INSTALLATION.
  
  
  
 1-14-10
 CHANGED TO FAILED STATUS BECAUSE 2ND SET OF PLANS IS
 MISSING SHEETS S1.01, THE ORIGINAL P1.01 PLUMBING PLAN,
 E1.01 & D1.01. WHEN TWO FULL SETS OF PLANS ARE
 SUBMITTED THEN THE STATUS WILL CHANGE.
  
  
  
  
  
 .

Review Stop P PLUMBING
Rev No 1 Status F Date 2009-12-01 Cont ID  
Sent By kstevens Date 2009-12-01 Time 13:15 Rev Time 0.00
Received By kstevens Date 2009-12-01 Time 17:43 Sent To  
Notes
2009-12-01 17:53:07DENIED
 REFERENCE:
 FBC-2007 PLUMBING
 FBC-2007 CHAPTER 1
  
 1. A SANITARY ISOMETRIC RISER DIAGRAM IS REQUIRED.
 SECTION 106.3.5.1.3(4)(6)(13). PLEASE SHOW ALL PIPE
 SIZES, TRAPS, VENTS ETC. SECTIONS 701.1, 901.1 &
 1001.1.
  
 2. A WATER ISOMETRIC RISER DIAGRAM IS REQUIRED. SECTION
 106.3.5.1.3(3)(10(13). PLEASE SHOW ALL PIPE SIZES,
 VALVES AND (WHERE REQD BY SECTION 604.9) WATER HAMMER
 ARRESTORS. SECTION 601.1.
  
 3. SHT G1.01 SCOPE OF WORK INDICATES "REMOVE & REPLACE
 KITCHEN CABINETS & APPLIANCES" WILL ANY OF THE
 APPLIANCES BE NEW APPLIANCES? IF YES WILL THERE BE ANY
 NEW GAS APPLIANCES? PLEASE CLARIFY.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  

Review Stop Z ZONING
Rev No 4 Status P Date 2010-02-25 Cont ID  
Sent By lfranco Date 2010-02-25 Time 12:03 Rev Time 0.00
Received By lfranco Date 2010-02-25 Time 12:03 Sent To I
Notes
2010-02-25 12:06:58PLANNING AND ZONING: **** PASSED WITH PROVISO: INTERIOR
 PERMIT WORK ONLY. PARKING AND STRIPPING SUB-PERMIT
 SUBMITTED UNDER #10020519. STILL MISSING LANDSCAPE
 PERMIT. KEEP HOLD FOR ANY BLDG. INSPECTIONS FOR PERMIT
 09110285 UNTIL LANDSCAPE PLANS ARE SUBMITTED. ROUTED TO
 RBROWN FOR PROCESSING. LMF

Review Stop Z ZONING
Rev No 3 Status F Date 2010-02-17 Cont ID  
Sent By lfranco Date 2010-02-17 Time 15:32 Rev Time 0.00
Received By lfranco Date 2010-02-17 Time 15:32 Sent To  
Notes
2010-02-17 15:36:07PLANNING AND ZONING: **** FAILED- 3RD TIME REPEAT
 COMMENTS NOT ADDRESSED - THIS PERMIT WILL NOT BE
 APPROVED UNTIL SEPARATE PERMITS FOR BOTH LANDSCAPING
 AND PAVING AND STRIPING PERMITS ARE SUBMITTED TO
 CONSTRUCTION SERVICES. ****
  
 1. RESPOND TO COMMENTS IN WRITING.
  
 2. APPLICANT NEEDS TO APPLY FOR A SEPARATE LANDSCAPE
 PERMIT.
  
 3. APPLICANT NEEDS TO APPLY FOR A SEPARATE PAVING AND
 STRIPING PERMIT AND PROVIDE A COPY OF THE ORIGINAL
 LAYOUT OF THE PARKING AREA THAT WAS APPROVED.
  
 THIS PERMIT CANNOT BE APPROVED UNTIL COMMENTS ABOVE ARE
 ADDRESSED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ME.
  
 LINDA MIA FRANCO
 SENIOR PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1443
 EMAIL: [email protected]

Review Stop Z ZONING
Rev No 2 Status F Date 2010-01-12 Cont ID  
Sent By lfranco Date 2010-01-12 Time 11:20 Rev Time 0.00
Received By lfranco Date 2010-01-12 Time 11:20 Sent To  
Notes
2010-01-12 11:24:30PLANNING AND ZONING: **** FAILED- REPEAT COMMENTS NOT
 ADDRESSED ****
  
 1. RESPOND TO COMMENTS IN WRITING.
  
 2. APPLICANT NEEDS TO APPLY FOR A SEPARATE LANDSCAPE
 PERMIT.
  
 3. APPLICANT NEEDS TO APPLY FOR A SEPARATE PAVING AND
 STRIPING PERMIT AND PROVIDE A COPY OF THE ORIGINAL
 LAYOUT OF THE PARKING AREA THAT WAS APPROVED.
  
 THIS PERMIT CANNOT BE APPROVED UNTIL COMMENTS ABOVE ARE
 ADDRESSED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ME.
  
 LINDA MIA FRANCO
 SENIOR PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1443
 EMAIL: [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2009-12-03 Cont ID  
Sent By ajones Date 2009-12-03 Time 10:00 Rev Time 0.00
Received By ajones Date 2009-12-03 Time 10:00 Sent To FIRE
Notes
2009-12-03 10:03:021. APPLICANT NEEDS TO APPLY FOR A SEPERATE LANDSCAPE
 PERMIT.
 2. APPLICANT NEEDS TO APPLY FOR A SEPERATE PAVING AND
 STRIPING PERMIT AND PROVIDE A COPY OF THE ORIGINAL
 LAYOUT OF THE PARKING AREA.