Plan Review Details - Permit 09110279
Plan Review Stops For Permit 09110279
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2010-01-20 Cont ID  
Sent By shill Date 2010-01-20 Time 13:36 Rev Time 0.00
Received By shill Date 2010-01-20 Time 13:36 Sent To  
Notes
2010-01-20 13:41:57****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007
 FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1. PLEASE CLARIFY EXPOSURE CLASSIFICATION. EOR HAS
 REVISED PLAN TO INCLUDE A STATEMENT WHICH STATES THAT
 EOR HAS CLASSIFIED THIS AS A B (BUT NO JUSTIFICATION AS
 REQUESTED IN PROVISO). PLEASE PROVIDE MORE INFORMATION
 AS AERIALS APPEAR TO PLACE THIS IN A C EXPOSURE. PLEASE
 ADVISE WHERE THE CODE ALLOWS SHIELDING BY OTHER
 BUILDINGS; ISN'T THAT SPECIFICALLY PROHIBITED? AS THIS
 IS A SCREEN ENCLOSURE, YOU MAY FIND THE FOLLOWING
 WEBSITE HELPFUL.
  
 HTTP://WWW.AAOF.ORG/
  
 HTTP://AAOF.ORG/DOCUMENTS/EXPOSURECATEGORY%28BOAF%29COM
 MENTARY.PDF
  
 ****PLEASE BE ADVISED THAT THE CODE CHANGED EFFECTIVE
 MARCH 1, 2009: PLEASE SEE NEW CODE (INCLUDING GLITCH
 AND SUPPLEMENTS) FOR "NEW" DEFINITIONS OF EXPOSURE
 CLASSIFICATIONS EFFECTIVE 3/1/09***
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2009-12-07 Cont ID  
Sent By shill Date 2009-12-07 Time 12:29 Rev Time 0.00
Received By shill Date 2009-12-07 Time 12:29 Sent To  
Notes
2009-12-07 12:36:00PROVISO - REVISE ENGINEERING TO EXPOSURE "C"
 ISSUED AT CONTRACTOR'S RISK
  
2009-12-07 12:31:01****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007
 FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1. REVISE EXPOSURE CATEGORY OR HAVE THE ENGINEER SEE
 AERIALS AND EXPLAIN RATIONALE FOR EXPOSURE B. FBC1609,
 FBC R301.2.1.4. NOTE THAT THE CODE CHANGED EFFECTIVE
 MARCH 1, 2009.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-12-07 Cont ID  
Sent By shill Date 2009-12-07 Time 12:31 Rev Time 0.00
Received By shill Date 2009-11-19 Time 09:10 Sent To Z
Notes
2009-11-19 09:10:22TO MISC #2
  

Review Stop Z ZONING
Rev No 1 Status P Date 2009-11-18 Cont ID  
Sent By shill Date 2009-12-07 Time 12:31 Rev Time 0.00
Received By kdfreema Date 2009-11-18 Time 15:23 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved