| Plan Review Stops For Permit 09110205 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2009-12-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-12-03 |
Time |
08:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-12-03 |
Time |
08:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2010-01-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-01-05 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-01-05 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2010-01-05 11:17:00 | SUBMITTED NEW PLANS |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2009-11-30 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-11-30 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-11-30 |
Time |
15:14 |
Sent To |
|
|
| Notes |
| 2009-11-30 15:16:55 | TO RES-POOLS BOX./WRT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2010-01-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-01-04 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-01-04 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2010-01-04 14:30:12 | TO RM DESK | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2009-12-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-12-17 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-12-17 |
Time |
12:58 |
Sent To |
|
|
| Notes |
| 2009-12-17 12:58:51 | SENT TO RMCDOUGAL. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2009-12-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-12-03 |
Time |
08:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-11-09 |
Time |
16:36 |
Sent To |
|
|
| Notes |
| 2009-11-09 16:36:50 | ZONING | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2010-01-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-01-05 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-01-05 |
Time |
11:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2009-12-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-12-22 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-12-22 |
Time |
11:47 |
Sent To |
Z |
|
| Notes |
| 2009-12-22 13:27:22 | 2007 FBC W/2009 REVISIONS | | | NEW RESIDENTIAL POOL | | | | | | DENIED BY BUILDING | | | | | | 1) ITEMS 2,3 FROM THE FIRST REVIEW WERE NOT ADDRESSED. | | | | | | 2) THE TURNOVER RATE SPECIFIED ON THE PLANS IS 2.2 HRS. | | | FOR A 14,178 GALLON POOL. THIS WILL REQUIRE A FLOW RATE | | | OF 107.4 GPM. THE PUMP SPECIFIED HAS A MAXIMUM FLOW | | | RATE OF 102 GPM. PLEASE REVISE. FBC R 4101.20 ALLOWS UP | | | TO 12 HOURS FOR TURNOVER. IN ORDER TO DETERMINE THE | | | TURNOVER RATE YOU WILL NEED TO KNOW THE TDH. | | | | | | 3) AT A FLOW RATE OF 102 GALLONS PER MINUTE THAT IS | | | SPECIFIED ON THE PLANS, THE 2.5" BRANCH PIPING BETWEEN | | | THE TWO MAIN DRAINS EXCEEDS THE 6 FT/SEC ALLOWED BY | | | ANSI/APSP-7. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2009-12-03 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-12-03 |
Time |
08:23 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-12-03 |
Time |
08:23 |
Sent To |
|
|
| Notes |
| 2009-12-03 09:33:54 | 2007 FBC W/2009 REVISIONS | | | NEW RESIDENTIAL POOL | | | | | | DENIED BY BUILDING | | | | | | 1) SUBMIT TWO COPIES OF THE MANUFACTURER'S | | | SPECIFICATIONS WITH A PUMP CURVE CHART FOR THE PUMP | | | THAT WILL BE INSTALLED. | | | | | | 2) SPECIFY THE THE TOTAL DYNAMIC HEAD FOR THE POOL | | | CIRCULATION SYSTEM. PROVIDE TWO COPIES OF THE | | | CALCULATIONS SHOWING HOW TDH WAS DETERMINED. | | | | | | 3) SPECIFY THE FLOW RATE FOR THE PUMP IN GPM AT THE TDH | | | DETERMINED FOR THE SYSTEM ON THE PLANS. | | | | | | 4) SUBMIT TWO COPIES OF MANUFACTURER'S SPECIFICATIONS, | | | FLOW RATING AND LISTING FOR THE MAIN DRAIN SUCTION | | | OUTLETS THAT WILL BE INSTALLED. | | | | | | 5) NOTE: THE EXISTING FENCE AND THE BARRIER BETWEEN THE | | | DWELLING AND THE POOL ARE REQUIRED TO COMPLY WITH THE | | | BARRIER OF FBC R4101.17. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2009-12-30 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2009-12-30 |
Time |
19:40 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2009-12-30 |
Time |
19:40 |
Sent To |
E |
|
| Notes |
| 2009-12-30 19:45:19 | PLANNING AND ZONING: **** PASSED WITH PROVISO, THE | | | EXISTING FENCE SHALL MEET THE REQUIREMENTS FOR | | | SELF-LATCHING AND LOCATED AT LEAST 54 INCHES ABOVE | | | BOTTOM OF GATE. **** REQUIREMENTS FOR POOL BARRIERS | | | SHALL BE NOTED BY BUILDING REVIEWER AND INSPECTOR. *** | | | | | | THE FENCE SHALL CONFORM TO THE MINIMUM STANDARDS | | | PROVIDED BELOW: | | | | | | PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND LAND | | | DEVELOPMENT REGULATIONS, SECTION, 94-304(D)(2)(B) AND | | | (C): | | | B. EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE OR | | | SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT ACCESS | | | BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF THE | | | RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED. | | | BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN | | | HEIGHT ABOVE GRADE. | | | C. ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE THROUGH | | | A BUILDING OR THROUGH A SELF-CLOSING AND SELF-LATCHING | | | GATE OR THROUGH A SCREEN ENCLOSURE DOOR WITH LATCHES | | | PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF GATE. AT | | | LEAST 90 PERCENT OF THE SURFACE AREA OF ALL SCREEN | | | ENCLOSURES SHALL BE SCREENING MATERIAL THROUGH WHICH | | | AIR SHALL FLOW. ALL POOLS LOCATED ON A CORNER LOT SHALL | | | BE SCREENED AT THE CORNER LOT LINE BY AT LEAST A | | | 42-INCH HIGH LANDSCAPE BUFFER, AS MEASURED FROM GRADE, | | | AT THE PROPERTY LINE, TO ENSURE PRIVACY. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
|
Date |
2009-11-19 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2009-11-19 |
Time |
19:47 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2009-11-19 |
Time |
19:47 |
Sent To |
E |
|
| Notes |
| 2009-11-19 20:22:14 | PLANNING AND ZONING **** FAILED **** | | | | | | 1. RESPOND TO COMMENTS IN WRITING. | | | | | | 2. AS THE SURVEY DOES NOT SHOW AN EXISTING PERMANENT | | | FENCE COMPLETELY SURROUNDING THE POOL, A FENCE PERMIT | | | SHALL BE SUBMITTED CONCURRENTLY AND SHALL CONFORM TO | | | THE MINIMUM STANDARDS PROVIDED BELOW: | | | | | | PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND LAND | | | DEVELOPMENT REGULATIONS, SECTION, 94-304(D)(2)(B) AND | | | (C): | | | B. EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE OR | | | SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT ACCESS | | | BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF THE | | | RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED. | | | BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN | | | HEIGHT ABOVE GRADE. | | | C. ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE THROUGH | | | A BUILDING OR THROUGH A SELF-CLOSING AND SELF-LATCHING | | | GATE OR THROUGH A SCREEN ENCLOSURE DOOR WITH LATCHES | | | PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF GATE. AT | | | LEAST 90 PERCENT OF THE SURFACE AREA OF ALL SCREEN | | | ENCLOSURES SHALL BE SCREENING MATERIAL THROUGH WHICH | | | AIR SHALL FLOW. ALL POOLS LOCATED ON A CORNER LOT SHALL | | | BE SCREENED AT THE CORNER LOT LINE BY AT LEAST A | | | 42-INCH HIGH LANDSCAPE BUFFER, AS MEASURED FROM GRADE, | | | AT THE PROPERTY LINE, TO ENSURE PRIVACY. | | | | | | AN APPROVED EASEMENT CONSENT FORM FROM THE CITY OF WEST | | | PALM BEACH DEPARTMENT OF PUBLIC UTILITIES (4TH FLOOR, | | | CITY HALL) IS REQUIRED FOR ALL PROPOSED FENCES/WALLS. | | | | | | WEST PALM BEACH PUBLIC UTILITIES DEPARTMENT | | | 401 CLEMATIS STREET | | | CITY HALL, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (561)822-1300 | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT ME. | | | | | | LINDA MIA FRANCO | | | SENIOR PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1443 | | | EMAIL: [email protected] | | | |
|
|