Plan Review Details - Permit 09110204
Plan Review Stops For Permit 09110204
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2009-11-30 Cont ID  
Sent By jwitmer Date 2009-11-30 Time 16:26 Rev Time 0.50
Received By jwitmer Date 2009-11-30 Time 16:26 Sent To  
Notes
2009-12-01 07:12:20BUILDING PROVISO: 424.2.17.1 OUTDOOR SWIMMING POOLS.
  
  
 424.2.17.1 OUTDOOR SWIMMING POOLS. OUTDOOR SWIMMING
 POOLS SHALL BE PROVIDED WITH A BARRIER COMPLYING WITH
 SECTIONS 424.2.17.1.1 THROUGH 424.2.17.1.14.
  
  
 424.2.17.1.1 THE TOP OF THE BARRIER SHALL BE AT LEAST
 48 INCHES (1219 MM) ABOVE GRADE MEASURED ON THE SIDE OF
 THE BARRIER WHICH FACES AWAY FROM THE SWIMMING POOL.
 THE MAXIMUM VERTICAL CLEARANCE BETWEEN GRADE AND THE
 BOTTOM OF THE BARRIER SHALL BE 2 INCHES (51 MM)
 MEASURED ON THE SIDE OF THE BARRIER WHICH FACES AWAY
 FROM THE SWIMMING POOL. WHERE THE TOP OF THE POOL
 STRUCTURE IS ABOVE GRADE THE BARRIER MAY BE AT GROUND
 LEVEL OR MOUNTED ON TOP OF THE POOL STRUCTURE. WHERE
 THE BARRIER IS MOUNTED ON TOP OF THE POOL STRUCTURE,
 THE MAXIMUM VERTICAL CLEARANCE BETWEEN THE TOP OF THE
 POOL STRUCTURE AND THE BOTTOM OF THE BARRIER SHALL BE 4
 INCHES (102 MM).
  
  
 424.2.17.1.2 THE BARRIER MAY NOT HAVE ANY GAPS,
 OPENINGS, INDENTATIONS, PROTRUSIONS, OR STRUCTURAL
 COMPONENTS THAT COULD ALLOW A YOUNG CHILD TO CRAWL
 UNDER, SQUEEZE THROUGH, OR CLIMB OVER THE BARRIER AS
 HEREIN DESCRIBED BELOW. ONE END OF A REMOVABLE CHILD
 BARRIER SHALL NOT BE REMOVABLE WITHOUT THE AID OF
 TOOLS. OPENINGS IN ANY BARRIER SHALL NOT ALLOW PASSAGE
 OF A 4-INCH DIAMETER (102 MM) SPHERE.
  
  
 424.2.17.1.3 SOLID BARRIERS WHICH DO NOT HAVE OPENINGS
 SHALL NOT CONTAIN INDENTATIONS OR PROTRUSIONS EXCEPT
 FOR NORMAL CONSTRUCTION TOLERANCES AND TOOLED MASONRY
 JOINTS.
  
  
 424.2.17.1.4 WHERE THE BARRIER IS COMPOSED OF
 HORIZONTAL AND VERTICAL MEMBERS AND THE DISTANCE
 BETWEEN THE TOPS OF THE HORIZONTAL MEMBERS IS LESS THAN
 45 INCHES (1143 MM), THE HORIZONTAL MEMBERS SHALL BE
 LOCATED ON THE SWIMMING POOL SIDE OF THE FENCE. SPACING
 BETWEEN VERTICAL MEMBERS SHALL NOT EXCEED 13/4 INCHES
 (44 MM) IN WIDTH. WHERE THERE ARE DECORATIVE CUTOUTS
 WITHIN VERTICAL MEMBERS, SPACING WITHIN THE CUTOUTS
 SHALL NOT EXCEED 13/4 INCHES (44 MM) IN WIDTH.
  
  
 424.2.17.1.5 WHERE THE BARRIER IS COMPOSED OF
 HORIZONTAL AND VERTICAL MEMBERS AND THE DISTANCE
 BETWEEN THE TOPS OF THE HORIZONTAL MEMBERS IS 45 INCHES
 (1143 MM) OR MORE, SPACING BETWEEN VERTICAL MEMBERS
 SHALL NOT EXCEED 4 INCHES (102 MM). WHERE THERE ARE
 DECORATIVE CUTOUTS WITHIN VERTICAL MEMBERS, SPACING
 WITHIN THE CUTOUTS SHALL NOT EXCEED 13/4 INCHES (44 MM)
 IN WIDTH.
  
  
 424.2.17.1.6 MAXIMUM MESH SIZE FOR CHAIN LINK FENCES
 SHALL BE A 2?? INCH (57 MM) SQUARE UNLESS THE FENCE IS
 PROVIDED WITH SLATS FASTENED AT THE TOP OR BOTTOM WHICH
 REDUCE THE OPENINGS TO NO MORE THAN 13/4 INCHES (44
 MM).
  
  
 424.2.17.1.7 WHERE THE BARRIER IS COMPOSED OF DIAGONAL
 MEMBERS, THE MAXIMUM OPENING FORMED BY THE DIAGONAL
 MEMBERS SHALL BE NO MORE THAN 13/4 INCHES (44 MM).
  
  
 424.2.17.1.8 ACCESS GATES, WHEN PROVIDED, SHALL BE
 SELF-CLOSING AND SHALL COMPLY WITH THE REQUIREMENTS OF
 SECTIONS 424.2.17.1.1 THROUGH 424.2.17.1.7 AND SHALL BE
 EQUIPPED WITH A SELF-LATCHING LOCKING DEVICE LOCATED ON
 THE POOL SIDE OF THE GATE. WHERE THE DEVICE RELEASE IS
 LOCATED NO LESS THAN 54 INCHES (1372 MM) FROM THE
 BOTTOM OF THE GATE, THE DEVICE RELEASE MECHANISM MAY BE
 LOCATED ON EITHER SIDE OF THE GATE AND SO PLACED THAT
 IT CANNOT BE REACHED BY A YOUNG CHILD OVER THE TOP OR
 THROUGH ANY OPENING OR GAP FROM THE OUTSIDE. GATES THAT
 PROVIDE ACCESS TO THE SWIMMING POOL MUST OPEN OUTWARD
 AWAY FROM THE POOL. THE GATES AND BARRIER SHALL HAVE NO
 OPENING GREATER THAN 1/2 INCH (12.7 MM) WITHIN 18
 INCHES (457 MM) OF THE RELEASE MECHANISM.
  
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2009-11-30 Cont ID  
Sent By dlauderm Date 2009-11-30 Time 10:14 Rev Time 1.00
Received By dlauderm Date 2009-11-30 Time 10:14 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-11-30 Cont ID  
Sent By jwitmer Date 2009-11-30 Time 16:26 Rev Time 0.00
Received By jwitmer Date 2009-11-18 Time 14:25 Sent To  
Notes
2009-11-18 14:26:01TO ENGINEERING
  
2009-11-09 16:42:12TO ZONING
  

Review Stop Z ZONING
Rev No 1 Status P Date 2009-11-13 Cont ID  
Sent By astelly Date 2009-11-13 Time 11:13 Rev Time 0.00
Received By astelly Date 2009-11-13 Time 11:13 Sent To  
Notes
***NONE***