Plan Review Details - Permit 09100371
Plan Review Stops For Permit 09100371
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-11-18 Cont ID  
Sent By rmcdouga Date 2009-11-18 Time 14:19 Rev Time 0.00
Received By rmcdouga Date 2009-11-18 Time 14:19 Sent To FIRE
Notes
2009-11-18 14:21:29REVISED SHEETS A-1.0 AND A-1.1 HAS BEEN REVIEWED FOR
 CODE COMPLIANCE. THE SUITE NUMBER WAS CHANGED FROM 125
 TO 100 AT THE REQUEST OF THE CONTRACTOR.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2009-10-22 Cont ID  
Sent By rmcdouga Date 2009-10-22 Time 17:25 Rev Time 0.00
Received By rmcdouga Date 2009-10-22 Time 17:25 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2009-11-30 Cont ID  
Sent By btrobaug Date 2009-11-30 Time 10:35 Rev Time 0.00
Received By btrobaug Date 2009-11-30 Time 10:05 Sent To  
Notes
2009-11-30 10:35:27TO LUIS./WRT. REVIEW SHOULD HAVE BEEN IN #09110593,
 REVISION , WILL ENTER RESULTS THERE./WRT

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2009-10-22 Cont ID  
Sent By btrobaug Date 2009-10-22 Time 07:34 Rev Time 0.00
Received By btrobaug Date 2009-10-22 Time 06:45 Sent To  
Notes
2009-10-22 07:35:13TO DOUG./WRT.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2009-11-18 Cont ID  
Sent By mawillia Date 2009-11-18 Time 15:17 Rev Time 0.00
Received By mawillia Date 2009-11-18 Time 15:03 Sent To  
Notes
2009-11-18 15:09:36*****REVISION #2, DATED 11/05/2009, APPROVED*****
  
 REVISED PLAN SHEETS A1.0 AND A1.1 WERE STAMPED,
 INITIALED, AND DATED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2009-10-27 Cont ID  
Sent By mcarsill Date 2009-10-27 Time 07:25 Rev Time 0.00
Received By mcarsill Date 2009-10-27 Time 07:04 Sent To  
Notes
2009-10-27 13:10:26*****FIRE STAMPED*****
  
 BASED UPON BATTALION CHIEF/FIRE MARSHAL APPROVAL OF THE
 SUBMITTED PLAN, SHEETS A1.0, A1.1, A1.2, A1.3, E2.1,
 AND FA0.1 & FA2.1 WERE STAMPED, INITIALED, AND DATED.
2009-10-27 07:24:24 
 1. FIRE DAMPERS ARE REQUIRED WHERE DUCTS PASS THROUGH
 RATED FIRE DOORS.
  
 2. ALL ELECTRICAL INSTALLATIONS TO COMPLY WITH NFPA 70,
 NATIONAL ELECTRIC CODE.
  
 3. SEPARATE PLANS AND PERMITS REQUIRED FOR ANY FIRE
 SPRINKLER SYSTEM OR FIRE ALARM SYSTEM REMODEL.
  
 4. INSTALLATIONS AR SUBJECT TO FIELD INSPECTION AND
 APPROVAL.
  
  
 APPROVED PROVISO
  
 MIKE CARSILLO, BATTALION CHIEF
 WEST PALM BEACH FIRE RESCUE
 500 NORTH DIXE HIGHWAY
 WEST PALM BEACH, FLORIDA 33401
 (561) 804-4709 PHONE
 (561) 804-4774 FAX
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-11-09 Cont ID  
Sent By jgomez Date 2009-11-09 Time 11:41 Rev Time 0.00
Received By jgomez Date 2009-11-09 Time 11:41 Sent To  
Notes
2009-11-09 11:42:27SENT TO R. MCDOUGAL'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-10-27 Cont ID  
Sent By dwise Date 2009-10-27 Time 15:44 Rev Time 0.00
Received By dwise Date 2009-10-27 Time 15:43 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2009-10-27 Cont ID  
Sent By dwise Date 2009-10-27 Time 15:43 Rev Time 0.00
Received By dwise Date 2009-10-27 Time 15:42 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status N Date 2009-11-30 Cont ID  
Sent By rregueir Date 2009-11-30 Time 16:23 Rev Time 0.00
Received By rregueir Date 2009-11-30 Time 16:23 Sent To  
Notes
2009-11-30 16:24:11SEE REVIEW UNDER TRACKING #09110593

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2009-11-18 Cont ID  
Sent By rregueir Date 2009-11-18 Time 14:38 Rev Time 0.00
Received By rregueir Date 2009-11-18 Time 14:38 Sent To  
Notes
2009-11-18 14:40:23ARCHITECTURAL PLANS REVISED TO REMOVE RATING FROM
 PARTITION. THIS ADDRESSES PROVISO ITEM #1. PROVISO ITEM
 #2 REGARDING DUCT SIZES IS STILL NOT ADDRESSED.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2009-10-21 Cont ID  
Sent By rregueir Date 2009-10-21 Time 19:45 Rev Time 0.00
Received By rregueir Date 2009-10-21 Time 19:43 Sent To  
Notes
2009-10-21 19:45:17***PROVISO***
  
 REVISION REQUIRED PRIOR TO ROUGH INSPECTION:
  
 1. SHOW FIRE DAMPERS AT SUPPLY AND RETURN DUCT
 PENETRATIONS OF 2-HOUR RATED WALL IN ACCORDANCE WITH
 FBC-M 607.5.2 AND FBC-M 607.8.
  
 2. SHOW SIZES OF ALL SUPPLY FLEXIBLE DUCTS ON PLANS IN
 ACCORDANCE WITH FBC-M 603.1 AND FBC-B 13-410.AB.1.2.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop P PLUMBING
Rev No 1 Status P Date 2009-10-27 Cont ID  
Sent By lwagner Date 2009-10-27 Time 14:32 Rev Time 0.00
Received By lwagner Date 2009-10-27 Time 14:24 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2009-10-27 Cont ID  
Sent By dwise Date 2009-10-21 Time 15:36 Rev Time 0.00
Received By dwise Date 2009-10-21 Time 15:36 Sent To  
Notes
2009-10-27 15:37:41ZONING REVIEW NOT REQUIRED PER ANGELLA.