Plan Review Details - Permit 09090592
Plan Review Stops For Permit 09090592
Review Stop AD ADDRESSING
Rev No 1 Status N Date 2009-10-13 Cont ID  
Sent By jnguyen Date 2009-10-13 Time 14:13 Rev Time 0.00
Received By jnguyen Date 2009-10-13 Time 10:46 Sent To  
Notes
2009-10-13 14:14:21*NO ADDRESSING REVIEW NECESSARY AS THE CONTRACTOR
 SIMPLY MADE A MISTAKE IN REFERENCING 905 45TH ST
 INSTEAD OF 901 45TH ST (RETURNED SITE PLANS BACK TO
 DEWEY).
  
  
 JOHN NGUYEN
 GIS SUPPORT SPECIALIST
 CITY OF WEST PALM BEACH
 MIS DEPARTMENT
 OFFICE: (561) 822-1239
 FAX: (561) 822-1249
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2009-10-21 Cont ID  
Sent By jgomez Date 2009-10-21 Time 15:53 Rev Time 0.00
Received By jgomez Date 2009-10-21 Time 15:52 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2009-10-13 Cont ID  
Sent By dpalmer Date 2009-10-13 Time 15:01 Rev Time 0.00
Received By dpalmer Date 2009-10-13 Time 15:01 Sent To  
Notes
2009-10-13 15:04:08NEW S&S SHEETS BROUGHT IN BY JACKIE. INSERTED NEW
 SHEETS AND STAMPED ELECTRICAL. WILL NEED TO GET
 PLUMBING TO RE-STAMP SHEETS.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2009-10-11 Cont ID  
Sent By dpalmer Date 2009-10-11 Time 11:05 Rev Time 0.00
Received By dpalmer Date 2009-10-11 Time 11:05 Sent To  
Notes
2009-10-11 11:05:20 
 ** DENIED/TEMPORARY
  
 1) NOTE: THE APPLICATION ADDRESS AS APPLIED ON PERMIT
 APPLICATION IS STATING 905 45TH ST. THIS IS NOT THE
 SAME AS LOCATION IN OUR SYSTEM UNDER THIS PCN OR THE
 PLANS. THE PLANS STATE 901. INFORMATION HAS BEEN SENT
 TO ADDRESSING REVIEW TO DETERMINE ACTUAL LOCATION. IF
 ADDRESS DOES CHANGE TO 905, THEN CONTRACTOR MAY ADJUST
 PLANS WITHOUT REPRINTING ALL SHEETS.
 SEE NOTE #2 BELOW.
  
  
 2) NOTE: THE SECOND SET OF ELECTRICAL PLANS ARE NOT
 SIGNED, DATED OR SEALED BY THE ENGINEER OF RECORD.
 PLEASE SEE FAC 61G15-23.002 WHICH REQUIRES ALL SETS OF
 DOCUMENTS INCLUDING JOBSITE SET AND OWNER SETS TO BE
 SIGNED, DATED AND SEALED ALSO. FS 471.025.
 AS THE ENGINEER OF RECORD IS LOCAL, A TIME CAN BE SET
 UP FOR ENGINEER TO COME INTO OFFICE TO SIGN AND SEAL
 PLANS. IDENTIFICATION OF DESIGN PROFESSIONAL MAY BE
 REQUIRED WHEN APPEARING IN PERSON.
 THE OTHER OPTION WOULD BE FOR THREE NEW SHEETS TO BE
 BROUGHT IN AND INSERTED INTO SETS BY THE CONTRACTOR. A
 TIME WOULD NEED TO BE SET UP FOR THIS TO TAKE PLACE.
  
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2009-10-22 Cont ID  
Sent By mawillia Date 2009-10-22 Time 13:04 Rev Time 0.00
Received By mawillia Date 2009-10-22 Time 12:11 Sent To  
Notes
2009-10-22 13:04:29*****APPROVED*****
  
  
 PLAN SHEETS AL2.2, A9.1, FP-1.0, AND E2.2 WERE STAMPED,
 INITIALED, AND DATED.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-12-09 Cont ID  
Sent By jwitmer Date 2009-12-09 Time 15:38 Rev Time 0.00
Received By jwitmer Date 2009-12-09 Time 15:38 Sent To  
Notes
2009-12-09 15:39:20REVISION SENT TO: BOX C17 09120219

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2009-10-22 Time   Rev Time 0.00
Received By shill Date 2009-09-30 Time 16:51 Sent To  
Notes
2009-09-30 16:52:00C23
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2009-10-21 Cont ID  
Sent By rregueir Date 2009-10-21 Time 20:11 Rev Time 0.00
Received By rregueir Date 2009-10-21 Time 20:11 Sent To  
Notes
2009-10-21 20:14:34***PROVISO***
  
 THE FOLLOWING CONDITIONS WERE NOTED ON PLANS:
  
 1. ALL PENETRATIONS OR OPENINGS IN FIRE AND SMOKE RATED
 ASSEMBLIES SHALL BE PROTECTED IN ACCORDANCE WITH FBC-M
 607.5.
  
 2. SUPPORTS FOR FLEXIBLE DUCTS SHALL BE MINIMUM 1.5
 INCHES WIDE PER FBC-M 603.5.6.6.
  
 3. PRODUCT APPROVALS ARE REQUIRED FOR WALL LOUVERS IN
 ACCORDANCE WITH F.A.C. RULE 9B-72.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop P PLUMBING
Rev No 1 Status P Date 2009-10-05 Cont ID  
Sent By kstevens Date 2009-10-05 Time 15:24 Rev Time 0.00
Received By kstevens Date 2009-10-05 Time 15:24 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2009-10-10 Cont ID  
Sent By lfranco Date 2009-10-10 Time 12:19 Rev Time 0.00
Received By lfranco Date 2009-10-10 Time 12:19 Sent To  
Notes
***NONE***