Plan Review Details - Permit 09090562
Plan Review Stops For Permit 09090562
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2009-10-13 Cont ID  
Sent By jnguyen Date 2009-10-13 Time 16:50 Rev Time 0.00
Received By jnguyen Date 2009-10-13 Time 08:51 Sent To  
Notes
2009-10-13 16:42:16THIS PERMIT WAS FOR THE REPLACEMENT OF FOUR STORAGE
 BUILDINGS AT THE SOLID WASTE AUTHORITY. I HAVE CHECKED
 OUT THE SITE PLANS & DETERMINED THAT THE TRUE ADDRESS
 LOCATION TO USE FOR THESE STRUCTURES WAS THE SECONDARY
 ADDRESS OF 6153 N JOG RD (ONE-STORY CBS BUILDING), NOT
 THE SECONDARY ADDRESS OF 6161 N JOG RD (HOUSE HAZARDOUS
 WASTE FACILITY). BESIDES THE FOUR STORAGE STRUCTURES
 BEING SITUATED CLOSER TO THE 6153 N JOG RD, I CONFIRMED
 IT WITH DEWEY IN THAT THEY WERE GOING TO BE FED
 ELECTRICALLY FROM THAT PARTICULAR LOCATION. IN THE
 PROCESS, I HAVE ADJUSTED THE ADDRESS ON THE ORIGINAL
 PERMIT APPLICATION FROM 6161 TO 6153 N JOG RD. IN
 COMMUNITYPLUS UNDER PCN# 74424234000001010, I HAVE ALSO
 MOVED IT TO BE CORRECTLY REFERENCED TO 6153 N JOG RD. I
 CALLED THE ARCHITECT, ALBERTO ZUNIGA TO INFORM HIM OF
 THE CORRECT ADDRESS TOO. I WILL BE RETURNING ALL OF THE
 ASSOCIATED DOCUMENTS BACK TO THE C19 BOX SHORTLY.
  
  
 JOHN NGUYEN
 GIS SUPPORT SPECIALIST
 CITY OF WEST PALM BEACH
 MIS DEPARTMENT
 OFFICE: (561) 822-1239
 FAX: (561) 822-1249
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2010-03-24 Cont ID  
Sent By jwitmer Date 2010-03-24 Time 16:42 Rev Time 1.33
Received By jwitmer Date 2010-03-24 Time 16:41 Sent To  
Notes
2010-03-24 16:53:15 
 BUILDING APPROVED WITH EXCEPTION!
 THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO
 CORRECT THE LISTED DEFICIENCIES
 IN THIS PLAN PRIOR TO INSPECTION WILL RESULT IN FAILED
 INSPECTION(S) AND THE ASSESSMENT
 OF RE-INSPECTION FEE(S).
  
 1) NO PRODUCT APPROVALS WERE SUBMITTED FOR WALL LOUVER
 2) NO PRODUCT APPROVALS WERE SUBMITTED FOR ROOFING
 ASSEMBLIES
 SUBMITION OF THESE ITEMS WILL BE CONSIDERED A REVISION
 AND
 REQUIRE ADDITIONAL REVIEW & ASSOCIATED FEES.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-10-07 Cont ID  
Sent By jwitmer Date 2009-10-07 Time 15:44 Rev Time 0.77
Received By jwitmer Date 2009-10-07 Time 15:44 Sent To  
Notes
2009-10-07 16:12:33BUILDING PLAN REVIEW
 PERMIT: 09090562
 ADD: 6161 N JOG RD
 CONT: "PLAN REVIEW"
 TEL: (561)684-75343
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 OCT 7/09
 1ST REVIEW
 ACTION: DENIED
  
 1) 1802.2.1 QUESTIONABLE SOIL. WHERE THE
 SAFE-SUSTAINING POWER OF THE SOIL IS IN DOUBT, OR WHERE
 A LOAD-BEARING VALUE SUPERIOR TO THAT SPECIFIED IN THIS
 CODE IS CLAIMED, THE BUILDING OFFICIAL SHALL REQUIRE
 THAT THE NECESSARY INVESTIGATION BE MADE. SUCH
 INVESTIGATION SHALL COMPLY WITH THE PROVISIONS OF
 SECTIONS 1802.4 THROUGH 1802.6 .
  
 2) MISSING DCA STATE APPROVED PLANS RULE 9B-1 FAC
  
 3) THE STRUCTURAL PLANS DO NOT INDICATE COMPLIANCE WITH
 ANCHORAGE OF STRUCTURE FOR MOMENT OF OVERTURNING AND
 SLIPPAGE.
 1604.4
 EVERY STRUCTURE SHALL BE DESIGNED TO RESIST THE
 OVERTURNING EFFECTS CAUSED BY THE LATERAL FORCES
 SPECIFIED IN THIS CHAPTER. SEE SECTION 1609 FOR WIND
 LOADS, AND SECTION 1610 FOR LATERAL SOIL LOADS.
  
 1604.9 COUNTERACTING STRUCTURAL ACTIONS. STRUCTURAL
 MEMBERS, SYSTEMS, COMPONENTS AND CLADDING SHALL BE
 DESIGNED TO RESIST FORCES DUE TO WIND, WITH
 CONSIDERATION OF OVERTURNING, SLIDING, AND UPLIFT.
 CONTINUOUS LOAD PATHS SHALL BE PROVIDED FOR
 TRANSMITTING THESE FORCES TO THE FOUNDATION. WHERE
 SLIDING IS USED TO ISOLATE THE ELEMENTS, THE EFFECTS OF
 FRICTION BETWEEN SLIDING ELEMENTS SHALL BE INCLUDED AS
 A FORCE.
  
 4) SINCE DCA PLANS WERE NOT SUBMITTED, PRODUCT
 APPROVALS FOR DOORS MAY NOT BE INCLUDED WITHIN THE DCA
 BUILDING. IF THE APPROVALS ARE NOT WIWTHIN THE STATE
 APPROVALS SEPERATE APPROVALS WILL BE REQUIRED, ALSO FOR
 ROOFING ASSEMBLIES IF NOT INCLUDED UNDER THE DCA PLANS.
 RULE 9B-72 FLORIDA ADMINISTRATIVE CODE.
  
 5) BUILDING # 4 INDICATES HAZARDOUS STORAGE BUT NO
 INFORMATION AS TO TYPE OF CHEMICALS, COMBUSTIBLE
 LIQUIDS, EXPLOSIVES, FLAMMABLE GAS AND OR LIQUIDS
 ORGANIC PEROXIDES OR OXIDIZERS NOR QUANITIES TO BE
 STORED. THESE UNKNOWNS WILL NEED TO BE DETERMINED TO
 SEE WHAT TYPE OF HAZARDOUS CLASSIFICATION IS REQUIRED
 AND SYSTEMS REQUIRED TO BE IN PLACE. TABLE 307.1(1).
  
 STARTING AUGUST 21, 2009, THE CONSTRUCTION SERVICES
 DEPARTMENT WILL BE CLOSED ON FRIDAYS UNTIL FURTHER
 NOTICE.
  
 OPENING HOURS MONDAY - THURSDAY WILL REMAIN AT 8:00 AM
 - 5:00 PM.
  
 JIM WITMER C. B. O.
 COMMERCIAL COMBINATION PLAN REVIEW
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
 SURVEY:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 CONSTRUCTION SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2010-03-31 Cont ID  
Sent By btrobaug Date 2010-03-31 Time 11:39 Rev Time 0.00
Received By btrobaug Date 2010-03-31 Time 08:14 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2009-10-11 Cont ID  
Sent By dpalmer Date 2009-10-11 Time 08:58 Rev Time 0.00
Received By dpalmer Date 2009-10-11 Time 08:58 Sent To  
Notes
2009-10-11 08:59:01 
  
 ** DENIED **
  
  
 1) NOTE: PLANS SUBMITTED FOR PLAN REVIEW ONLY AND HAVE
 NOT BEEN SUBMITTED UNDER PERMIT APPLICATION BY A
 LICENSED CONTRACTOR.
 PLANS ALSO STATE FOR PLAN REVIEW ONLY.
  
 2) NOTE: WHEN SUBMITTING FOR PERMIT. PLEASE BE AWARE OF
 RECENT CODE CHANGES SUCH AS THE ADOPTION OF THE 2008
 NEC.
 PLANS WILL BE REQUIRED TO STATE THE RELEVANT CODES FOR
 WHICH DESIGN IS RELEVANT.
 IF SUBMITTING FOR PERMIT AFTER OCTOBER 1ST, 2009 THE
 FOLLOWING FOR ELECTRICAL REVIEW WOULD NEED TO BE ON
 PLANS.
 2007 FBC W/2009 SUPPLEMENTS.
 2008 NFPA-70
  
 3) NOTE: WHEN SUBMITTING FOR PERMIT PLEASE BE SURE
 PLANS ARE SIGNED, DATED AND SEALED BY THE RESPONSIBLE
 DESIGNER OF RECORD.
 FAC 61G15-23.002, FS 471.025
  
 4) NOTE: PLEASE EXPAND ON THE DISCONNECTING MEANS AT
 THE DETACHED BUILDINGS. PLANS CONTAIN A NOTE FOR A
 DISCONNECT HOWEVER NO OTHER INFORMATION.
 225.31-225.39
  
 5) NOTE: PLEASE SEE 250.32, 250.32 D OF THE NEC FOR
 GROUNDING ELECTRODE SYSTEM REQUIRED AT EACH STRUCTURE
 OR MEET EXCEPTION. BASED ON THE PANEL SCHEDULE AND THE
 RISER THE NUMBER OF CONDUCTORS IS NOT SHOWN.
 PLEASE EXPAND ON THE GROUNDING ELECTRODE ATTACHMENT TO
 THE FOUNDATION/FOOTER STEEL. WILL THIS STEEL BE BONDED?
 WILL THIS BE USED AS A GROUNDING ELECTRODE?
 THE FUTURE BUILDING USE MAY BE OTHER THAN STORAGE. AS
 CONDUCTORS ARE NOT SHOWN IT IS NOT CLEAR FOR CODE
 COMPLIANCE DETERMINATION.
 SEE 250.50,250.122, FOR SIZING AND ATTACHMENT TO FOOTER
 STEEL IF NOT MEETING EXCEPTION.
  
 PLEASE EXPLAIN THE 4INCH FIRE LINES INDICATED AT THE
 OUTSIDE OF EACH STRUCTURE. OTHER SHEETS INDICATE THESE
 WILL BE CAPPED OFF.
 BONDING MAY BE REQUIRED PER 250.104.
  
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2010-03-29 Cont ID  
Sent By mcarsill Date 2010-03-29 Time 14:42 Rev Time 0.00
Received By mcarsill Date 2010-03-29 Time 14:41 Sent To  
Notes
2010-03-29 14:44:52 
  
 6153 NORTH JOG ROAD
  
 1. PREVIOUS COMMENTS PROVIDED BY THIS DEPARTMENT STILL
 APPLY TO THE PROJECT.
  
 2. COMPLIANCE WITH CHAPTER 42, STORAGE OCCUPANCIES IS
 REQUIRED.
  
 3. ALL WORK SUBJECT TO FIELD INSPECTION AND APPROVAL.
  
  
 MIKE CARSILLO, BATTALION CHIEF
 BUREAU OF FIRE PREVENTION
 (561) 804-4724 PHONE
 (561) 804-4774 FAX

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2009-10-21 Cont ID  
Sent By mcarsill Date 2009-10-21 Time 16:31 Rev Time 0.00
Received By mcarsill Date 2009-10-21 Time 16:26 Sent To  
Notes
2009-10-21 16:31:45 
 1. DEMOLITION, RENOVATION, AND CONSTRUCTION TO COMPLY
 WITH NFPA 241.
  
 2. PLEASE INDICATE THE TYPES OF MATERIALS PLANNED TO BE
 STORED IN BUILDINGS 1,2, & 3.
  
 3. PLEASE INDICATE THE TYPES OF HAZARDOUS MATERIALS
 THAT WILL BE STORED IN BUILDING # 4. ALSO THE MAXIMUM
 QUANTITIES OF THESE MATERIALS SHOULD BE PROVIDED ON THE
 PLANS.
  
 4. SEPARATE PLANS AND PERMITS REQUIRED FOR THE
 SUPPRESSION SYSTEM PLANNED FOR BUILDING # 4.
  
 5. PLEASE INDICATE OCCUPANCY FOR THESE STORAGE
 BUILDINGS.
  
 6. PLEASE ILLUSTRATE ALL SAFETY EQUIPMENT PLANNED FOR
 THE STORAGE BUILDINGS.
  
 7. SEPARATE PLANS AND PERMITS REQUIRED FOR THE FIRE
 ALARM EQUIPMENT.
  
  
 DENIED
  
 MIKE CARSILLO, BATTALION CHIEF
 WEST PALM BEACH FIRE RESCUE
 BUREAU OF FIRE PREVENTION
 500 NORTH DIXIE HIGHWAY
 WEST PALM BEACH, FLORIDA 33401
 (561) 804-4709 PHONE
 (561) 804-4774 FAX
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2010-03-15 Cont ID  
Sent By jgomez Date 2010-03-15 Time 15:14 Rev Time 0.00
Received By jgomez Date 2010-03-15 Time 14:38 Sent To  
Notes
2010-03-15 15:15:08SENT TO C3.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2009-10-22 Time   Rev Time 0.00
Received By shill Date 2009-09-29 Time 15:01 Sent To  
Notes
2009-09-29 15:02:04C19
  

Review Stop Z ZONING
Rev No 2 Status P Date 2010-03-18 Cont ID  
Sent By kdfreema Date 2010-03-18 Time 09:05 Rev Time 0.00
Received By kdfreema Date 2010-03-18 Time 09:05 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2009-10-01 Cont ID  
Sent By kdfreema Date 2009-10-01 Time 14:57 Rev Time 0.00
Received By kdfreema Date 2009-10-01 Time 14:57 Sent To  
Notes
2009-10-01 14:58:41FAILED STATUS WILL BE CHANGED TO PASSED STATUS UPON
 APPLICATION FOR PERMIT.
  
 PLEASE CONTACT KELLY FREEMAN, GIS PLANNER, AT
 561-822-1458 WITH QUESTIONS.