| Plan Review Stops For Permit 09090432 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2009-11-02 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-11-02 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-11-02 |
Time |
11:56 |
Sent To |
PC |
|
| Notes |
| 2009-11-02 11:57:01 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | | | 1- IF ROOF REPAIRS/REPLACEMENT IS MORE THAN 25% OF THE | | | TOTAL ROOF AREA, THEN THE ENTIRE ROOF SYSTEM NEEDS TO | | | BE REPLACED AS REQUIRED BY SEC. 611.1.1 OF 2007 FLORIDA | | | BUILDING CODE-EXISTING BUILDING. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2009-10-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-10-15 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-10-15 |
Time |
15:40 |
Sent To |
PARK |
|
| Notes |
| 2009-10-15 15:43:45 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | | | 1- IF ROOF REPAIRS/REPLACEMENT IS MORE THAN 25% OF THE | | | TOTAL ROOF AREA, THEN THE ENTIRE ROOF SYSTEM NEEDS TO | | | BE REPLACED AS REQUIRED BY SEC. 611.1.1 OF 2007 FLORIDA | | | BUILDING CODE-EXISTING BUILDING. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2009-10-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-10-26 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-10-26 |
Time |
08:36 |
Sent To |
|
|
| Notes |
| 2009-10-26 08:36:46 | ** PROVISO ** | | | | | | ** REVISED PLANS TO BE SUBMITTED BEFORE ROUGH | | | ELECTRICAL INSPECTION. ALL WIRING PER 2005 NEC, 2002 | | | NFPA-72. | | | | | | 1) NOTE: PLEASE SUBMIT PANEL SCHEDULE (S) SHOWING ALL | | | MINIMUM BRANCH CIRCUITS, OVER CURRENT PROTECTION SIZES | | | AND CONDUCTOR SIZES. ALL CONDUCTOR SIZES AND BREAKERS | | | CAN NOT BE VERIFIED AT THIS TIME. THIS WAS GONE OVER | | | WITH ARCHITECT AS THERE IS UNCOVERED EXISTING | | | ELECTRICAL NOT KNOWN AT THIS TIME. | | | PLEASE SEE SECTIONS: 210.52, 210.52B1, 210.11C1, C2, | | | C3, 210.52C1-C5, 210.8A6, 408.6, 310.16, 240.4 ETC | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2009-10-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-10-08 |
Time |
20:03 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-10-08 |
Time |
20:03 |
Sent To |
|
|
| Notes |
| 2009-10-08 20:03:51 | | | | ** DENIED PLANS ** | | | | | | * ELECTRICAL PERMIT IS BEING APPLIED FOR YET NO | | | ELECTRICAL PLANS/ DETAILS ARE BEING SUBMITTED. | | | | | | 1) NOTE: PLEASE SUBMIT ELECTRICAL PLANS SHOWING SCOPE | | | OF WORK MEETING MINIMUM ELECTRICAL CODE COMPLIANCE WITH | | | THE 2005 NEC. ( NFPA-70). | | | PLANS INDICATE SOME NEW PARTITIONS ETC HOWEVER NO | | | ELECTRICAL IS SHOWN. | | | PLEASE SEE 210.52 FOR RECEPTACLE SPACE FOR WALLS. | | | PLEASE SEE 210.52B1 FOR MINIMUM SMALL APPLIANCE | | | CIRCUITS. | | | PLEASE SEE 210.52C1-5 FOR COUNTER SPACE RECEPTACLES | | | REQUIRED IN KITCHEN AND SEE 210.8A6 FOR GFI PROTECTION. | | | PLEASE SEE 210.12 FOR REQUIRED ARC FAULT PROTECTION. | | | PLEASE SEE 210.52D FOR REQUIRED BATHROOM RECEPTACLES. | | | PLEASE SEE 210.11C3 FOR THE BATH CIRCUITS. | | | PLEASE SEE 210.70 FOR LIGHTING AND CONTROL DEVICES. | | | ETC. | | | | | | 2) NOTE: PLEASE SEE R313.1.2 FOR SMOKE ALARMS WHICH ARE | | | REQUIRED TO MEET CURRENT NFPA-72 CODES. 11.5.1,11.8.3. | | | PLEASE SHOW LAYOUT OF EXISTING OR NEW MEETING CURRENT | | | CODES. | | | | | | ** IT IS IMPORTANT TO KNOW THAT AS NO ELECTRICAL IS | | | SHOWN OR SUBMITTED FOR REVIEW THERE MAY VERY WELL BE | | | NEW COMMENTS ON THE FOLLOWING REVIEW AS MINIMUMS CAN | | | NOT BE REVIEWED AT THIS TIME. | | | | | | **IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2009-12-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-12-09 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-12-09 |
Time |
09:26 |
Sent To |
|
|
| Notes |
| 2009-12-09 09:29:09 | PLUMBING REVISION #09120180 ROUTED TO K. STEVENS DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2009-10-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-10-20 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-10-20 |
Time |
16:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2009-10-15 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-10-15 |
Time |
15:43 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-09-22 |
Time |
15:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2009-10-27 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-10-27 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-10-27 |
Time |
10:55 |
Sent To |
|
|
| Notes |
| 2009-10-27 11:26:49 | PASSED/PROVISO | | | | | | REVISION REQUIRED FOR SANITARY RISER DIAGRAM. SECTIONS | | | 901.2 & 909.1.1 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2009-09-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-09-23 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-09-23 |
Time |
14:46 |
Sent To |
|
|
| Notes |
| 2009-09-23 14:54:55 | DENIED | | | REFERENCE: | | | FBC-2007 RESIDENTIAL | | | | | | 1. SHT A4.1 PLUMBING RISER DIAGRAM DOES NOT MEET CODE. | | | PLEASE CORRECT THE FOLLOWING: | | | A. MASTER BATH TUB VENT DOES NOT MEET THE REQUIREMENTS | | | OF CODE SECTIONS P3104.3 & P3104.4. | | | B. MASTER BATH W/C AND SHOWER SHALL CONNECT TO THE | | | BRANCH LINE FOR THE BATHROOM FIXTURES, NOT THE W/M | | | STACK. SECTION P3101.2. | | | C. POWDER ROOM W/C SHALL CONNECT TO THE BRANCH LINE TO | | | THE LAV, NOT THE STACK FOR THE SECOND FLOOR BATHROOM. | | | SECTION P3107.3. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2009-09-30 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2009-09-30 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2009-09-30 |
Time |
11:03 |
Sent To |
ENG-CON |
|
| Notes |
|
|