| Plan Review Stops For Permit 09090338 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
N |
Date |
2010-04-28 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2010-04-28 |
Time |
09:42 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2010-04-28 |
Time |
09:42 |
Sent To |
|
|
| Notes |
| 2010-04-28 09:46:06 | ACCORDING TO DOUG WISE. NEED TO VOID THIS PERMIT AND | | | APPLY FOR NEW PERMIT. SCOPE OF WORK RESUBMITTED IS | | | COMPLETELY DIFFERENT FROM WHAT WHAT'S SUBMITTED | | | ORIGINALLY. ONLY THE PLAN REVIEW FEES ARE CHARGED ON | | | THIS PERMIT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2010-04-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2010-04-08 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2010-04-08 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2010-04-08 13:23:06 | RECEIVED 2ND SET OF PLANS. JG. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
|
Date |
2010-04-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2010-04-07 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2010-04-07 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2010-04-07 14:36:22 | BUILDING REVIEW APPROVED WITH PROVISO (PLANS WILL BE | | | STAMPED WHEN REQUESTED INFORMATION IS PROVIDED): | | | | | | 1- ONLY ONE SIGNED AND SEALED SET OF PLANS WAS | | | PROVIDED. NEED TO PROVIDE TWO COMPLETE SETS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
|
Date |
2010-04-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2010-04-05 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2010-04-05 |
Time |
15:59 |
Sent To |
|
|
| Notes |
| 2010-04-05 16:06:52 | BUILDING REVIEW APPROVED WITH PROVISO (PLANS WILL BE | | | STAMPED WHEN REQUESTED INFORMATION IS PROVIDED): | | | | | | 1- ONLY ONE SIGNED AND SEALED SET OF PLANS WAS | | | PROVIDED. NEED TO PROVIDE TWO COMPLETE SETS. | | | | | | 2- ONLY ONE SET OF WINDOWS PRODUCT APPROVAL WAS | | | PROVIDED. NEED TO PROVIDE TWO SETS. PLEASE MAKE SURE | | | BOTH SETS ARE REVIEWED AND APPROVED IN WRITING BY THE | | | ENGINEER OF RECORD. | | | | | | 3- PROVIDE 2 COPIES OF PRODUCT APPROVALS AS REQUIRED BY | | | DCA RULE 9B-72 FOR WINDOW MULLIONS AS SHOWN ON PLANS ON | | | THE FLORIDA ROOM. AND, ENGINEER OF RECORD TO REVIEW IT | | | AND APPROVE IT IN WRITING PRIOR TO SUBMITTAL. (NONE WAS | | | SUBMITTED AT THIS TIME). | | | | | | 4- CLARIFY IF INSTALLING THE PRE-MANUFACTURED GARAGE | | | WITH THIS PERMIT. PLANS FROM THE DEPARTMENT OF | | | COMMUNITY AFFAIRS ARE FOR A SHED BUILDING. NOT A | | | GARAGE. PROVIDE PLANS FOR AN APPROVED PRE- MANUFACTURED | | | GARAGE BUILDING. PROVIDE TWO COPIES AND TWO COPIES OF | | | THE ENGINEERED (SIGNED AND SEALED) ANCHORING DETAILS. | | | | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561)805-6712 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2009-10-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-10-13 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-10-13 |
Time |
16:04 |
Sent To |
PC |
|
| Notes |
| 2009-10-13 16:11:33 | RESIDENTIAL (R3) GARAGE ADDITION, BUILDING REVIEW | | | CHECKLIST. | | | 2007 FL. RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | | | 1- PERMIT APPLICATION CALLS FOR NEW DETACHED GARAGE AND | | | DRIVEWAY EXTENSION. PLANS SUBMITTED INCLUDE BEDROOM | | | ADDITION. AS PER CONVERSATION WITH OWNER, THE BEDROOM | | | ADDITION IS NOT PART OF THIS PERMIT APPLICATION. REVISE | | | PLANS AS REQUIRED. ALSO, PLANS TO MATCH SURVEY. | | | | | | 2- PROVIDE RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13 | | | FLORIDA STATUTE. | | | ***NOTE: THIS MAY BE RECORDED LATER AT TIME OF PERMIT | | | PICK UP. | | | | | | 3- ENGINEER OF RECORD TO SIGN AND SEAL BOTH SETS OF | | | PLANS. CHAPTER 471 FLORIDA STATUTE. SIGN AND SEAL ALL | | | PAGES. | | | | | | 4- PROVIDE 2 COPIES OF PRODUCT APPROVALS AS REQUIRED BY | | | DCA RULE 9B-72 FOR: | | | A) GARAGE DOOR. | | | B) EXTERIOR OUTSWING DOOR. | | | C) SINGLE HUNG WINDOWS. | | | D) SHINGLES. | | | | | | 5- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC. | | | | | | 6- PROVIDE COMPLETE FRAMING DETAILS FOR GARAGE AND | | | EXTERIOR SWING DOOR TO VERIFY COMPLIANCE WITH THE | | | DESIGN PRESSURES OF SEC. R301. | | | | | | 7- GARAGE ROOF PITCH OF 3:12 REQUIRES 2 LAYERS OF | | | UNDERLAYMENT. SEC. R905.2.2. | | | | | | 8- REVISE WINDOW NOTE #3 ON SHEET #1. SEE PRODUCT | | | APPROVAL FOR MAXIMUM SHIM ALLOWED. | | | | | | 9- SPECIFY ROOF VENTILATION AS REQUIRED BY SEC. R806 OF | | | 2007 FLORIDA RESIDENTIAL CODE. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
N |
Date |
2010-04-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2010-04-08 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2010-04-08 |
Time |
13:25 |
Sent To |
|
|
| Notes |
| 2010-04-08 13:26:31 | NO ELECTRICAL WORK. SCOPE OF WORK REVISED FOR | | | PREMANUFACTURED SHED AND REPLACEMENT OF 3 WINDOWS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2009-10-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-10-08 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-10-08 |
Time |
15:45 |
Sent To |
|
|
| Notes |
| 2009-10-08 15:46:01 | ** DENIED** | | | | | | | | | 1) NOTE: PERMIT APPLICATION STATES TO BUILD A NEW | | | DETACHED GARAGE HOWEVER THE PLANS ALSO INCLUDE A | | | REMODEL AND ADDITION TO THE EXISTING DWELLING INCLUDING | | | NEW BEDROOM. WHAT IS THE ACTUAL SCOPE OF WORK? | | | THIS AFFECTS THE REVIEW BEING DONE FOR MINIMUM CODE | | | COMPLIANCE. | | | PLEASE DESCRIBE PROJECT AND APPLIED SCOPE OF WORK. SEE | | | NOTES BELOW AS SCOPE OF WORK FOR ELECTRICAL IS ALSO IN | | | QUESTION. | | | 105.1, 106.1.1, 106.5 FOR CLARITY OF RECORD PLANS AND | | | APPLIED SCOPE OF WORK | | | | | | 2) NOTE: PLEASE BE SURE THE FOLLOWING MINIMUM CODES ARE | | | PLACED ON PLANS FOR MINIMUM DESIGN. | | | 2007 FBC W/ 2009 REVISIONS | | | 2002 NFPA-72 | | | 2005 NFPA-70 | | | | | | ** REQUIRED MINIMUMS. STATING THE NATIONAL ELECTRICAL | | | CODE COULD MEAN SEVERAL CODE EDITIONS. | | | | | | 3) NOTE: PLEASE PROVIDE A LAYOUT OF THE EXISTING | | | DWELLING SHOWING NEW OR EXISTING SMOKE ALARMS MEETING | | | CURRENT NFPA-72 CODES. | | | PLEASE SEE R313.1.2 AS THIS REQUIRES SMOKE ALARMS TO BE | | | BROUGHT UP TO CODE. | | | PLEASE SEE NFPA-72 11.5.1, 11.8.3 FOR CURRENT | | | REQUIREMENTS INSIDE AND OUTSIDE ALL SLEEPING ROOMS ETC. | | | | | | 4) NOTE: THE ELECTRICAL PLANS CONTAINS A NOTE FOR THE | | | RISER WHICH STATES TO *REMOVE AND UPGRADE* EXISTING | | | SERVICE YET NO NEW INFORMATION IS SHOWN FOR NEW | | | SERVICE, NEW AIC RATINGS, NEW SERVICE CONDUCTORS, | | | MAINS, NO OVER CURRENT PROTECTION FOR SUB PANEL ETC. | | | CODE COMPLIANCE FOR MANY ITEMS CAN NOT BE REVIEWED IF | | | INFORMATION IS NOT SUBMITTED SHOWING MINIMUM. | | | PLEASE SEE 230.70, 230.71, 310.16,240.4,110.9, 215.5 | | | ETC | | | | | | 5) NOTE: PLEASE SUBMIT LOAD CALCULATIONS FOR SERVICE | | | PER NEC 220 | | | | | | 6) NOTE: PLEASE SEE 250.32 AND 250.50 FOR GROUNDING | | | ELECTRODE SYSTEM AT DETACHED GARAGE. | | | | | | 7) NOTE: BATH CIRCUIT(S) PER 210.11C3 | | | | | | 8) NOTE: ARC FAULT PROTECTION PER 210.12 | | | | | | ** PLEASE KNOW THAT AS THERE IS INFORMATION NOT YET | | | SHOWN FOR MINIMUM CODE COMPLIANCE THERE MAY BE NEW | | | COMMENTS ON THE FOLLOWING REVIEW WHICH CAN NOT BE MADE | | | AT THIS TIME. | | | | | | | | | | | | | | | **IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2010-04-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2010-04-05 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2010-04-01 |
Time |
08:53 |
Sent To |
|
|
| Notes |
| 2010-04-01 08:55:57 | INCOMING SENT TO R-8 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2009-10-13 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-10-13 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-09-16 |
Time |
10:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
N |
Date |
2010-04-26 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2010-04-26 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2010-04-26 |
Time |
11:17 |
Sent To |
|
|
| Notes |
| 2010-04-26 11:19:32 | ***LANDSCAPE REVIEW NOT REQUIRED*** | | | | | | THE SCOPE OF WORK AND THE COST WAS CHANGED TO BE LESS | | | THAN 50% OF THE IMPROVEMENT VALUE. THEREFORE, NO | | | LANDSCAPING IS REQUIRED.---RAK |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
2009-09-29 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-09-29 |
Time |
17:47 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-09-29 |
Time |
17:47 |
Sent To |
|
|
| Notes |
| 2009-09-29 18:00:20 | ***LANDSCAPE REVIEW FAILED*** | | | | | | PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN WRITTEN | | | FORMAT. | | | | | | 1. PURSUANT TO SECTION 94-441 (C)(2), A COMPLETE | | | LANDSCAPE PLAN IS REQUIRED WHEN RENOVATIONS, REPAIR, | | | ALTERATION OR REDEVELOPMENT EXCEEDS 50 PERCENT OF THE | | | VALUE OF THE STRUCTURE. PLEASE SUBMIT A LANDSCAPE PLAN | | | AND PROVIDE THE TABULATION NECESSARY FOR THE EVALUATION | | | OF COMPLIANCE WITH ARTICLE XIV OF THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS, INCLUDING THE XERISCAPE DESIGN | | | OPTIONS. | | | | | | 2. PURSUANT TO SECTION 94-448 (D)(2), THE LANDSCAPE | | | PLAN SHALL INCLUDE ALL OF THE ITEMS MENTIONED IN THIS | | | SECTION. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2010-04-08 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2010-04-08 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2010-04-08 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2010-04-08 13:25:11 | NO PLUMBING WORK. SCOPE OF WORK REVISED FOR | | | PREMANUFACTURED SHED AND REPLACING 3 WINDOWS. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2009-09-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-09-21 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-09-21 |
Time |
09:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2010-04-27 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2010-04-27 |
Time |
13:41 |
Rev Time |
0.50 |
| Received By |
lfranco |
Date |
2010-04-27 |
Time |
|
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2009-10-01 |
|
|
Cont ID |
|
| Sent By |
lfranco |
Date |
2009-10-01 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
lfranco |
Date |
2009-10-01 |
Time |
16:23 |
Sent To |
|
|
| Notes |
| 2009-10-02 17:02:50 | PLANNING AND ZONING: ***** FAILED**** | | | | | | 1. RESPOND TO COMMENTS IN WRITING. REVISIONS MAY | | | GENERATE ADDITIONAL COMMENTS. | | | | | | 2. THE SURVEY DOES NOT CORRELATE WITH THE SITE PLAN/ | | | FLOOR PLAN ON SHEET 1. FOR EXAMPLE, THE SURVEY DOES NOT | | | SHOW THE EXISTING SHED, ADJACENT TO THE CORNER OF THE | | | HOUSE, PLEASE CLARIFY. | | | | | | 3. SHEET 1 DATED 9/9/09 - PROVIDE LOCATION OF | | | COLUMN/STRUCTURAL SUPPORT FOR THE EXISTING COVERED | | | PATIO. PROVIDE REMAINDER DIMENSION BETWEEN INTERIOR | | | EDGE AND ACCESS DRIVE CLEARANCE. THE VEHICLE TURNING | | | RADIUS FOR MANEUVERING IS VERY TIGHT; THERE IS NO ROOM | | | FOR BACK-OUT SPACE FOR THE VEHICLE TO TURN AROUND TO | | | EGRESS (EXIT) THE DRIVEWAY IN THE REAR. PROVIDE BACK-UP | | | AREA, AT SOUTH SIDE OF A MINIMUM OF 13 FEET DEEP BY 20 | | | FEET WIDE (THE WIDTH DIMENSION WILL BE FROM THE | | | WESTERN-MOST CORNER OF THE PROPOSED DRIVE, HEADING | | | EAST). ALSO, CONSIDER ROUNDING OUT THE INTERIOR CORNER | | | EDGE OF THE DRIVE-WAY TO ALLOW FOR MANEUVERING. | | | | | | 4. PROVIDE TOTAL HEIGHT OF DETACHED GARAGE. | | | | | | PLEASE CONTACT ME, SHOULD YOU HAVE ANY QUESTIONS. | | | | | | LINDA MIA FRANCO | | | SENIOR PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1443 | | | EMAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|