| Plan Review Stops For Permit 09090334 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2010-01-05 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2010-01-05 |
Time |
16:46 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-01-05 |
Time |
16:46 |
Sent To |
|
|
| Notes |
| 2010-01-05 16:46:57 | PROCESS PLANS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2009-12-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-12-21 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-12-21 |
Time |
14:10 |
Sent To |
|
|
| Notes |
| 2009-12-21 14:10:47 | SECOND SET OF PLANS WAS SUBMITTED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2009-12-17 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-12-17 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-12-17 |
Time |
11:58 |
Sent To |
|
|
| Notes |
| 2009-12-17 12:01:29 | ALTHOUGH BUILDING COMMENTS HAVE BEEN ADDRESSED, ONLY | | | ONE SET OF REVISED DRAWINGS WERE SUBMITTED. TWO | | | COMPLETE SETS OF PLANS ARE REQUIRED. SUBMIT ADDITIONAL | | | SET OF PLANS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2009-10-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-10-26 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-10-26 |
Time |
13:29 |
Sent To |
|
|
| Notes |
| 2009-10-26 13:47:15 | 2007 FBC W/2009 REVISIONS | | | REPAIRS | | | | | | DENIED BY BUILDING | | | | | | 1) SUBMIT 2 COPIES OF PRODUCT APPROVALS FOR THE NEW | | | EXTERIOR ENTRY AND REAR DOORS AS REQUIRED BY DCA RULE | | | 9B-72. | | | | | | 2) SUBMIT 2 COPIES OF PRODUCT APPROVALS FOR THE NEW | | | WINDOWS AS REQUIRED BY DCA RULE 9B-72, IF THEY ARE | | | BEING REPLACED. PRODUCT APPROVALS ARE NOT REQUIRED IF | | | ONLY THE GLAZING IS TO BE REPLACED AND THE EXISTING | | | FRAMES REMAIN IN THE OPENINGS. | | | | | | 3) SHOW THE LOCATIONS OF THE SMOKE ALARMS ON THE PLANS | | | AS REQUIRED BY FBC R313.2 AND R313.2.1. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] | | 2009-10-26 10:46:40 | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2010-01-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2010-01-12 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2010-01-12 |
Time |
09:55 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2009-12-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-12-22 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-12-22 |
Time |
08:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2009-10-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-10-26 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-10-26 |
Time |
10:41 |
Sent To |
|
|
| Notes |
| 2009-10-26 10:53:29 | | | | | | | DENIED INCOMPLETE INFORMATION | | | | | | 1} THERE ARE ELECTRICAL PLANS PROVIDED BUT NO | | | ELECTRICAL WORK IN THE DESCRIPTION ON THE | | | APPLICATION.SUBMIT PLANS INDICATING THE SCOPE OF WORK. | | | 106.1 FBC AS AMENDED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2010-01-05 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2010-01-05 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2010-01-05 |
Time |
14:57 |
Sent To |
|
|
| Notes |
| 2010-01-05 15:04:55 | *****APPROVED***** | | | | | | | | | PLAN SHEETS A-1, LS-1, AND E-1 STAMPED, INITIALED, AND | | | DATED. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2009-12-17 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-12-17 |
Time |
13:53 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-12-17 |
Time |
13:26 |
Sent To |
|
|
| Notes |
| 2009-12-17 13:53:21 | *****PARTIAL APPROVAL***** | | | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE | | | BEEN ADDRESSED AS FOLLOWS: | | | | | | | | | 1. STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241 - 2004 | | | EDITION. ON SHEET LS-1, RED-LINE TO 241 INSTEAD OF 214 | | | | | | 2. NFPA 101, LIFE SAFETY CODE, 2006 EDITION SHALL BE | | | REFERENCED. ON SHEET LS-1 | | | | | | 3. PROVIDE OCCUPANT LOAD CHARACTERISTIC OF THE USE OF | | | THE SPACE OF DETERMINED AS THE MAXIMUM PROABLE | | | POPULATION OF THE SPACE UNDER CONSIDERATION, WHICHEVER | | | IS GREATER. ON SHEET LS-1 | | | | | | 4. SPECIFY INTERIOR FINISH FOR WALLS AND CEILINGS IN | | | TERMRS OF CLASS A, CLASS B, OR CLASS C. ON SHEET LS-1 | | | | | | 5. SHOW THE LOCATION OF THE SMOKE ALARMS WHICH SHALL BE | | | INSTALLED OUTSIDE EVERY SLEEPING AREA IN THE IMMEDIATE | | | VICINITY OF THE BEDROOMS. PLEASE BE ADVISED THAT SMOKE | | | ALARMS, WITH BATTERY BACK-UP, SHALL RECEIVE THEIR | | | OPERATING POWER FROM THE BUILDING ELECTRICAL SYSTEM. ON | | | SHEET A-1 & E-1 | | | | | | 6. SHOW LOCATION OF THE 2A:10BC RATED FIRE | | | EXTINGUISHER(S). THIS MAY BE ACCOMPLISHED BY EITHER ONE | | | OF THE FOLLOWING: 1) PROVIDE ONE FIRE EXTINGUISHER ON | | | THE OUTSIDE COMMON TO ALL THREE DWELLING UNITS OR 2) | | | PROVIDE ONE EXTINGUISHER INSIDE EACH DWELLING UNIT. ON | | | SHEET LS-1 | | | | | | 7. VERIFY THAT THE NUMERICAL ADDRESS FOR THE BUILDING | | | (AT LEAST 6" IN HEIGHT AND 1" IN WIDTH) IS VISIBLE FROM | | | 5TH STREET. IN ADDITION EACH DWELLING UNIT DESIGNATION | | | (AT LEAST 3" IN HEIGHT AND 1" IN WIDTH) IS POSTED. | | | UNDERSTOOD BY CONTRACTOR | | | | | | PLEASE BE ADVISED HOWEVER THAT ONLY ONE SET OF PLANS | | | HAVE BEEN SUBMITTED; PLANS HEETS A-1, LS-1, AND E-1 TO | | | BE FIRE-STAMPED WHEN AN ADDITIONAL, NO MORE THAN TWO | | | ADDITIONAL, PLAN SET HAS BEEN SUBMITTED. | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2009-10-26 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-10-26 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-10-26 |
Time |
11:54 |
Sent To |
|
|
| Notes |
| 2009-10-26 12:36:56 | *****DENIED***** | | | | | | | | | 1. STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241 - 2004 | | | EDITION. | | | | | | 2. NFPA 101, LIFE SAFETY CODE, 2006 EDITION SHALL BE | | | REFERENCED. | | | | | | 3. PROVIDE OCCUPANT LOAD CHARACTERISTIC OF THE USE OF | | | THE SPACE OF DETERMINED AS THE MAXIMUM PROABLE | | | POPULATION OF THE SPACE UNDER CONSIDERATION, WHICHEVER | | | IS GREATER. | | | | | | 4. SPECIFY INTERIOR FINISH FOR WALLS AND CEILINGS IN | | | TERMRS OF CLASS A, CLASS B, OR CLASS C. | | | | | | 5. SHOW THE LOCATION OF THE SMOKE ALARMS WHICH SHALL BE | | | INSTALLED OUTSIDE EVERY SLEEPING AREA IN THE IMMEDIATE | | | VICINITY OF THE BEDROOMS. PLEASE BE ADVISED THAT SMOKE | | | ALARMS, WITH BATTERY BACK-UP, SHALL RECEIVE THEIR | | | OPERATING POWER FROM THE BUILDING ELECTRICAL SYSTEM. | | | | | | 6. SHOW LOCATION OF THE 2A:10BC RATED FIRE | | | EXTINGUISHER(S). THIS MAY BE ACCOMPLISHED BY EITHER ONE | | | OF THE FOLLOWING: 1) PROVIDE ONE FIRE EXTINGUISHER ON | | | THE OUTSIDE COMMON TO ALL THREE DWELLING UNITS OR 2) | | | PROVIDE ONE EXTINGUISHER INSIDE EACH DWELLING UNIT. | | | | | | 7. VERIFY THAT THE NUMERICAL ADDRESS FOR THE BUILDING | | | (AT LEAST 6" IN HEIGHT AND 1" IN WIDTH) IS VISIBLE FROM | | | 5TH STREET. IN ADDITION EACH DWELLING UNIT DESIGNATION | | | (AT LEAST 3" IN HEIGHT AND 1" IN WIDTH) IS POSTED | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2010-01-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2010-01-12 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2010-01-12 |
Time |
09:59 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2009-12-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-12-14 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-12-14 |
Time |
14:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2009-10-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-10-28 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-09-16 |
Time |
10:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2009-12-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-12-21 |
Time |
14:15 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-12-21 |
Time |
14:15 |
Sent To |
|
|
| Notes |
| 2009-12-21 14:16:36 | MECHANICAL EQUIPMENT TO BE REPLACED LIKE FOR LIKE IN | | | EXISTING LOCATIONS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2009-10-26 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-10-26 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-10-26 |
Time |
11:14 |
Sent To |
|
|
| Notes |
| 2009-10-26 11:15:41 | PROVIDE EQUIPMENT SCHEDULE FOR NEW EQUIPMENT TO BE | | | INSTALLED. INDICATE WHETHER THIS IS A LIKE-FOR-LIKE | | | CHANGE OUT OR IF ANY EQUIPMENT SIZES ARE BEING CHANGED. | | | CHANGES IN EQUIPMENT SIZE WILL REQUIRE COOLING AND | | | HEATING LOAD CALCULATIONS TO BE SUBMITTED. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2009-12-21 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-12-21 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-12-21 |
Time |
14:11 |
Sent To |
|
|
| Notes |
| 2009-12-21 14:14:36 | PLUMBING PERMIT REQUIRED TO REPLACE WATER HEATERS. | | | EXISTING IRRIGATION SYSTEM WAS FOUND TO BE WORKING. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2009-10-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-10-28 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-10-28 |
Time |
09:49 |
Sent To |
|
|
| Notes |
| 2009-10-28 09:51:18 | AN IRRIGATION PERMIT AND A PLUMBING PERMIT IS REQUIRED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2010-01-05 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2010-01-05 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2010-01-05 |
Time |
13:47 |
Sent To |
|
|
| Notes |
| 2010-01-05 13:59:07 | PROVISO: | | | A REVISED SITE PLAN SHALL BE SUBMITTED INCLUDING THE | | | PARKING SPACES ALLOWED BYTHE WIDTH OF THE APPROACH. THE | | | REMAINING AREA SHALL BE MARKED AS NO PARKING AREA. | | | WHEEL STOPS SHALL BE AT SCALE. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2009-10-26 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2009-10-26 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2009-10-26 |
Time |
15:27 |
Sent To |
|
|
| Notes |
| 2009-10-26 15:41:59 | NOTES ON PLAN A-1 INDICATE LANDSCAPING AND SPRINKLER | | | SYSTEM WILL BE INSTALLED, BUT DRAWINGS DEPICTING | | | PROPOSED WORK WERE NOT SUBMITTED. | | | NOTES ON PLAN A-1 INDICATE REMOVAL AND REPLACEMENT OF | | | WHEEL STOPS, BUT DRAWINGS DEPICTING PROPOSED WORK WERE | | | NOT SUBMITTED. | | | PLEASE SUBMIT SITE PLAN INDICATING LANDSCAPE | | | IMPROVEMENTS AND SITE IMPROVEMENTS. PROPERTY LINES | | | SHALL BE INCLUDED. | | | PLEASE SUBMIT A SURVEY OF THE PROPERTY. | | 2009-10-26 10:52:15 | | | | | | | DENIED/INCOMPLETE INFORMATION | | | | | | | | | THE DESCRIPTION ON THE APPLICATION INDICATES ELECTRICAL | | | WORK TO BE DONE UNDER THIS PERMIT BUT NO ELECTRICAL | | | PLANS WERE SUBMITTED. SUBMIT PLANS INDICATING THE SCOPE | | | OF WORK.. 106.1 FBC AS AMENDED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | |
|
|