Plan Review Details - Permit 09090223
Plan Review Stops For Permit 09090223
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2009-11-09 Cont ID  
Sent By shill Date 2009-11-09 Time 14:49 Rev Time 0.00
Received By shill Date 2009-11-09 Time 14:49 Sent To  
Notes
2009-11-09 14:50:25****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007
 FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 COMMENTS FROM PREVIOUS LIST:
  
 1. ADDRESSED.
  
 2. IMPACT FEE ASSESSMENT TO BE PERFORMED BY PALM BEACH
 COUNTY. THE PLANS MUST BE STAMPED AND THE RECEIPT, IF
 FEES ARE DUE, IS TO BE ATTACHED TO THE APPLICATION.
 233-5025 FOR MORE INFORMATION.
  
 PER MICHELLE, PALM BEACH COUNTY, NO IMPACT FEE
 ASSESSMENT REQUIRED.
  
 3. ON THE EXISTING HOUSE FLOOR PLAN, SHOW ROOM
 DESIGNATIONS FOR THE ROOMS WHICH HAVE OPENINGS INTO THE
 PORCH. IF A BEDROOM IS AFFECTED, SHOW THAT THE BEDROOM
 HAS ANOTHER EMERGENCY MEANS OF ESCAPE FBC R310.
  
 NOT ADDRESSED.
  
 4. IMPACT PROTECTION REQUIRED FBC R301.2.1.2. AS
 PRODUCT APPROVALS WERE NOT SUBMITTED, IT IS DIFFICULT
 TO DETERMINE WHETHER OR NOT THE PROPOSED PRODUCTS
 COMPLY. I ACCESSED ONE ON THE INTERNET (PGT242.3), AND
 THAT PRODUCT WAS NOT IMPACT RESISTANT. PROVIDE PRODUCT
 APPROVALS AND, IF SHUTTERS ARE USED, COMPLETE THE
 SAMPLE INSTALLATION SCHEDULE (AVAILABLE IN THE LOBBY
 AND AT HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDU
 LE_FOR_INSTALLATION.PDF). ADJUST VALUE TO INCLUDE
 IMPACT PROTECTION.
  
 2ND REVIEW, NOT ADDRESSED. IT APPEARS THAT THE
 EXCEPTION IN THE CODE (FBC301.2.1.2) FOR SUNROOMS,
 BALCONIES, AND ENCLOSED PORCHES DOES NOT APPLY AS I WAS
 NOT ABLE TO FIND EVIDENCE THAT THE EXISTING BUILDING
 HAS FBC COMPLIANT OPENING PROTECTION (A REQUIREMENT FOR
 THE EXCEPTION).
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-09-29 Cont ID  
Sent By shill Date 2009-09-29 Time 09:54 Rev Time 0.00
Received By shill Date 2009-09-29 Time 09:54 Sent To  
Notes
2009-09-29 10:13:32****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007
 FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1. PROVIDE TWO SETS OF ALL PRODUCT APPROVALS. PRINT THE
 FLORIDA STATE PRODUCT APPROVAL COVER SHEET, EVALUATION
 REPORT, INSTALLATION INSTRUCTIONS. FAC9B72.
  
 2. IMPACT FEE ASSESSMENT TO BE PERFORMED BY PALM BEACH
 COUNTY. THE PLANS MUST BE STAMPED AND THE RECEIPT, IF
 FEES ARE DUE, IS TO BE ATTACHED TO THE APPLICATION.
 233-5025 FOR MORE INFORMATION.
  
 3. ON THE EXISTING HOUSE FLOOR PLAN, SHOW ROOM
 DESIGNATIONS FOR THE ROOMS WHICH HAVE OPENINGS INTO THE
 PORCH. IF A BEDROOM IS AFFECTED, SHOW THAT THE BEDROOM
 HAS ANOTHER EMERGENCY MEANS OF ESCAPE FBC R310.
  
 4. IMPACT PROTECTION REQUIRED FBC R301.2.1.2. AS
 PRODUCT APPROVALS WERE NOT SUBMITTED, IT IS DIFFICULT
 TO DETERMINE WHETHER OR NOT THE PROPOSED PRODUCTS
 COMPLY. I ACCESSED ONE ON THE INTERNET (PGT242.3), AND
 THAT PRODUCT WAS NOT IMPACT RESISTANT. PROVIDE PRODUCT
 APPROVALS AND, IF SHUTTERS ARE USED, COMPLETE THE
 SAMPLE INSTALLATION SCHEDULE (AVAILABLE IN THE LOBBY
 AND AT HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/PDF/SCHEDU
 LE_FOR_INSTALLATION.PDF). ADJUST VALUE TO INCLUDE
 IMPACT PROTECTION.
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2009-11-05 Cont ID  
Sent By btrobaug Date 2009-11-05 Time 17:22 Rev Time 0.00
Received By btrobaug Date 2009-11-05 Time 17:16 Sent To B
Notes
2009-11-05 17:22:53TO SAMANTHA./WRT.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2009-09-23 Cont ID  
Sent By jleahy Date 2009-09-23 Time 08:32 Rev Time 0.00
Received By jleahy Date 2009-09-23 Time 08:32 Sent To B1
Notes
2009-09-23 08:36:211) NEEDS OUTLETS INSTALLED ACCORDING TO 210.52(A)(1)(2)
  
 2) NEEDS LIGHTING OUTLET(S) INSTALLED ACCORDING TO
 210.70(A)
  
 ALL WALLS SHALL HAVE OUTLETS INSTALLED 6' FROM THE
 OPENING AND THEN EVERY 12'.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-11-04 Cont ID  
Sent By lmartine Date 2009-11-03 Time 09:29 Rev Time 0.00
Received By shill Date 2009-11-03 Time 09:29 Sent To  
Notes
2009-11-05 11:21:36ROUTED TO BT (ELECTRIC)
  
2009-11-04 09:30:14GAVE TO SAMANTHA

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-09-29 Cont ID  
Sent By shill Date 2009-09-29 Time 10:13 Rev Time 0.00
Received By shill Date 2009-09-15 Time 11:02 Sent To  
Notes
2009-09-15 11:02:57SENT TO ZONING.

Review Stop Z ZONING
Rev No 1 Status P Date 2009-09-16 Cont ID  
Sent By eschneid Date 2009-09-16 Time 17:37 Rev Time 0.10
Received By eschneid Date 2009-09-16 Time 17:37 Sent To E
Notes
***NONE***