Plan Review Details - Permit 09090130
Plan Review Stops For Permit 09090130
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-10-19 Cont ID  
Sent By shill Date 2009-10-19 Time 08:58 Rev Time 0.00
Received By shill Date 2009-10-19 Time 08:58 Sent To  
Notes
2009-10-19 09:01:33****ISSUED WITH PROVISOS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007 WITH 2009 SUPPLEMENTS
  
 1. FBC11-4.6, PER PROPERTY MANAGER, THIS BUILDING IS R2
 (APARTMENTS) WITH AGE RESTRICTIONS
  
 "H" ON PLAN ARE ACCESSIBLE PARKING SPACES
  
 2. SUBJECT TO FIELD INSPECTOR'S DISCRETION, REPAIR OF
 CONCRETE MAY REQUIRE A DETAIL - REVISION FEES WOULD
 APPLY.
  
 PREVIOUS COMMENT STATED - APPLICATION STATES: REPAIR &
 REPLACE CONCRETE & WELL COVER. CLARIFY SCOPE OF WORK.
 INCORPORATE INTO DRAWING. IT IS NOT CLEAR IF THIS IS
 WITHIN THE SCOPE OF WORK FOR THIS LICENSE.
 RESUBMITTAL STATES "SEE ATTACHMENT 1." NO ATTACHMENT.
 PLEASE PROVIDE.
  
 3. TWO COMPLETE IDENTICAL SETS OF DOCUMENTS REQUIRED.
 ONLY ONE FLOOR PLAN AND ONE LANDSCAPE PLAN SUBMITTED.
 PER ZONING, SECOND SET OF LANDSCAPE PLAN REQUIRED. HAVE
 ADDITIONAL COPY AVAILABLE AT INSPECTION - A RESTAMP MAY
 BE REQUIRED (WITH APPROPRIATE FEES) SUBJECT TO
 LANDSCAPE INSPECTOR'S DISCRETION.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2009-10-14 Cont ID  
Sent By shill Date 2009-10-14 Time 11:54 Rev Time 0.00
Received By shill Date 2009-10-14 Time 11:54 Sent To  
Notes
2009-10-14 12:11:57****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007 WITH 2009 SUPPLEMENTS
  
 1. FBC11-4.6, PROVIDE THE FOLLOWING INFORMATION ON THE
 PLAN:
  
 OCCUPANCY CLASSIFICATION PER FBC CHAPTER 3 - 2ND
 REVIEW, IS THIS R2 (APARTMENTS) OR I1 (ASSISTED LIVING)
 OR ANOTHER OCCUPANCY? CONTRACTOR IS TO DECLARE
 OCCUPANCY CLASSIFICATION SO THAT REQUIRMENTS CAN BE
 DETERMINED
 IF THERE IS MORE THAN ONE OCCUPANY, PROVIDE A PARTIAL
 FLOOR PLAN AS NEEDED TO DEMONSTRATE CODE COMPLIANCE -
 SHOW ALL OFFICES, CLUBHOUSE/RECREATION AREAS, ETC. -
 FLOOR PLAN PROVIDED, BUT ONLY ONE SET. PLEASE PROVIDE
 SECOND SET.
 TOTAL NUMBER OF PARKING SPACES - ADDRESSED
 TOTAL NUMBER OF ACCESSIBLE SPACES - ADDRESSED (IF "H"
 IS ACCESSIBLE PARKING - PLEASE CLARIFY). NOT CLEAR AT
 THIS POINT IF LOCATION IS CODE COMPLIANT OR IF
 ACCESSIBLE PARKING IS TO BE DISPERSED PER FBC11-4.6.2.
  
 2. ADDRESSED.
  
 3. APPLICATION STATES: REPAIR & REPLACE CONCRETE & WELL
 COVER. CLARIFY SCOPE OF WORK. INCORPORATE INTO DRAWING.
 IT IS NOT CLEAR IF THIS IS WITHIN THE SCOPE OF WORK FOR
 THIS LICENSE.
 RESUBMITTAL STATES "SEE ATTACHMENT 1." NO ATTACHMENT.
 PLEASE PROVIDE.
  
 NEW COMMENT:
  
 4. TWO COMPLETE IDENTICAL SETS OF DOCUMENTS REQUIRED.
 ONLY ONE FLOOR PLAN AND ONE LANDSCAPE PLAN SUBMITTED.
 PER ZONING, SECOND SET OF LANDSCAPE PLAN REQUIRED.
 PLEASE PROVIDE ADDITIONAL SECOND SET OF DOCUMENTS WHEN
 RESUBMITTING.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-09-22 Cont ID  
Sent By shill Date 2009-09-22 Time 14:51 Rev Time 0.00
Received By shill Date 2009-09-22 Time 14:51 Sent To  
Notes
2009-09-22 15:30:55****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007 WITH 2009 SUPPLEMENTS
  
 1. FBC11-4.6, PROVIDE THE FOLLOWING INFORMATION ON THE
 PLAN:
  
 OCCUPANCY CLASSIFICATION PER FBC CHAPTER 3
 IF THERE IS MORE THAN ONE OCCUPANY, PROVIDE A PARTIAL
 FLOOR PLAN AS NEEDED TO DEMONSTRATE CODE COMPLIANCE -
 SHOW ALL OFFICES, CLUBHOUSE/RECREATION AREAS, ETC.
 TOTAL NUMBER OF PARKING SPACES
 TOTAL NUMBER OF ACCESSIBLE SPACES
  
 2. THE BUILDING AND PARKING LOT CONFIGURATION DOES NOT
 MATCH THE AERIAL PHOTOGRAPHS. PLEASE PROVIDE A MORE
 ACCURATE DRAWING FBC*106. SHOW COMPASS NORTH ON THE
 DRAWING.
  
 3. APPLICATION STATES: REPAIR & REPLACE CONCRETE & WELL
 COVER.
  
 CLARIFY SCOPE OF WORK. INCORPORATE INTO DRAWING. IT IS
 NOT CLEAR IF THIS IS WITHIN THE SCOPE OF WORK FOR THIS
 LICENSE.
  
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-09-29 Cont ID  
Sent By shill Date 2009-09-29 Time 10:53 Rev Time 0.00
Received By shill Date 2009-09-29 Time 10:53 Sent To  
Notes
2009-10-07 14:44:5210/7 TO SH DESK
  
2009-09-29 10:53:14TO ZONING BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-09-22 Cont ID  
Sent By shill Date 2009-09-22 Time 15:31 Rev Time 0.00
Received By shill Date   Time   Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2009-10-05 Cont ID  
Sent By astelly Date 2009-10-05 Time 12:42 Rev Time 0.00
Received By astelly Date 2009-10-05 Time 12:42 Sent To  
Notes
2009-10-05 12:43:50AMY STELLY
 PLANNING & ZONING
 561.822.1442
  
 PROVISO
 ALL PARKING SPACES MUST BE DIMENSIONED AND RE-STRIPED
 AS PER SEC.94-485, FIG. XV-2 OF THE ZLDR.
 ADDITIONALLY, ALL MISSING LANDSCAPE MUST BE RESTORED AS
 PER THE ORIGINAL LANDSCAPE PLAN SUBMITTED WITH THE
 PERMIT.

Review Stop Z ZONING
Rev No 1 Status F Date 2009-09-14 Cont ID  
Sent By astelly Date 2009-09-14 Time 09:57 Rev Time 0.00
Received By astelly Date 2009-09-14 Time 09:57 Sent To B
Notes
2009-09-14 10:58:50AMY F. STELLY
 PLANNING AND ZONING
 561.822.1442
  
  
 PLEASE PROVIDE
 1. A SITE PLAN WHICH ACCURATELY SHOWS THE SIZE,
 LOCATION AND NUMBER OF PARKING SPACES AS WELL AS ALL
 LANDSCAPE ISLANDS;
 2. A COPY OF THE ORIGINAL LANDSCAPE PLANS TO ENSURE
 THAT THE EXISTING LANDSCAPE IS IN COMPLIANCE; OR
 3. A NEW LANDSCAPE PLAN WHICH COMPLIES WITH ARTICLE XIV
 OF THE ZONING AND LAND DEVELOPMENT REGULATIONS.
  
  
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved