| Plan Review Stops For Permit 09090030 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2010-04-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2010-04-05 |
Time |
11:53 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2010-04-05 |
Time |
11:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2009-09-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-09-22 |
Time |
13:13 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2009-09-22 |
Time |
10:30 |
Sent To |
|
|
| Notes |
| 2009-09-22 13:25:07 | BUILDING PLAN REVIEW | | | PERMIT: 09090030 | | | ADD: 1200 S FLAGLER DR/ ROOFTOP | | | CONT: J. CROMPTON ELECTRIC, INC | | | TEL: (321)288-7093 | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) S-2 DETAIL# 2 INDICATES THE RISE ON THE STAIRS AS 10 | | | INCHES, PLEASE REVIEW SECTION 1009.3 EXCEPTION# 6. | | | | | | 2) S-3 DETAIL# 2 INDICATES A CROSS OVER BRIDGE | | | ELEVATION, 106.1.2 ADDITIONAL INFORMATION REQUIRED, | | | THERE IS NO INFORMATION AS TO MATERIALS AND DIMENSIONS. | | | | | | 3) S-3 DETAIL# 2 ALSO DOES NOT INDICATE HOW THE CROSS | | | OVER BRIDGE IS GOING TO BE FASTENED TO THE PRECAST | | | FIBERCRETE PAD NOR HOW THE BRIDGE IS GOING TO RESIST | | | THE MOMENT OF OVERTURNING. | | | 1604.4 EVERY STRUCTURE SHALL BE DESIGNED TO RESIST THE | | | OVERTURNING EFFECTS CAUSED BY LATERAL FORCES SPECIFIED | | | IN THIS CHAPTER. SEE SECTION 1609 FOR WIND . | | | | | | STARTING AUGUST 21, 2009, THE CONSTRUCTION SERVICES | | | DEPARTMENT WILL BE CLOSED ON FRIDAYS UNTIL FURTHER | | | NOTICE. | | | | | | OPENING HOURS MONDAY - THURSDAY WILL REMAIN AT 8:00 AM | | | - 5:00 PM. | | | | | | JIM WITMER C. B. O. | | | COMMERCIAL COMBINATION PLAN REVIEW | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | SURVEY: | | | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2010-04-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2010-04-09 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2010-04-09 |
Time |
11:06 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2009-09-24 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-09-24 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-09-24 |
Time |
08:22 |
Sent To |
|
|
| Notes |
| 2009-09-24 08:23:02 | ** DENIED ** | | | | | | | | | | | | 1) NOTE: PLEASE SEE 445.18 AND PROVIDE METHOD TO | | | COMPLY. PLEASE KEEP IN MIND A SHUNT TRIP TYPE BREAKER | | | IS NOT ACCEPTABLE. IN AN EMERGENCY SITUATION AND POWER | | | IN THE BUILDING NEEDS TO BE SHUT DOWN, THERE IS NOT WAY | | | FOR FIRE DEPARTMENT OR OTHER PERSONAL TO SHUT DOWN | | | GENERATOR UNLESS GOING TO THE ROOF TO DO SO. | | | A READILY ACCESSIBLE MEANS OF SHUTTING DOWN PRIME MOVER | | | SUPPLY MUST BE INSTALLED IN CLOSE PROXIMITY TO THE MAIN | | | ELECTRICAL ROOM/FIRE COMMAND ROOM WHEN LOCATED ON SITE. | | | A GENERATOR STATUS PANEL MUST ALSO INDICATE THE UNIT | | | STATUS. | | | PLEASE ALSO PLACE NOTES ON PLANS FOR REQUIRED SIGNAGE | | | AT ALL OF THE ABOVE LOCATIONS. | | | | | | 2) NOTE: THE PROPOSED VALUE IS LOW. THE VALUE IS | | | REQUIRED TO INCLUDE THE FOLLOWING EVEN IF ANY OF THESE | | | ARE OWNER SUPPLIED. | | | DESIGN/PLANS FEE. | | | ALL LABOR, | | | ALL EQUIPMENT, ( GENERATOR AND ATS) | | | ALL MATERIALS ETC | | | | | | FBC 108.3 | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2010-04-06 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2010-04-06 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2010-04-06 |
Time |
10:53 |
Sent To |
|
|
| Notes |
| 2010-04-06 11:14:52 | *****APPROVED**** | | | | | | REVIEWED/APPROVED BY MIKE CARSILLO ON 03/29/2010, PLAN | | | SHEETS C3, C4, C6, E4, AND E5 WERE STAMPED, INITIALED, | | | AND DATED BY THIS WRITER. | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2009-09-18 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2009-09-18 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2009-09-18 |
Time |
16:31 |
Sent To |
|
|
| Notes |
| 2009-09-18 16:37:44 | | | | 1. PLEASE PROVIDE PRESCRIPTIVE STRENGTH REQUIREMENTS | | | FOR HANDRAILS. | | | | | | 2. GAS PIPING AND APPURTENANT EQUIPMENT SHALL COMPLY | | | WITH THE APPROPRIATE NFPA STANDARDS. INSTALLATION SHALL | | | BE PERFORMED TO RECOGNIZED STANDARDS AND IN A SAFE | | | MANNER. | | | | | | 3. THE INSTALLATION OF ANY EQUIPMENT SHALL NOT | | | INTERFERE WITH ANY EXITING, EXIT ACCESS OR ACCESS TO | | | ANY FIRE SAFETY EQUIPMENT. THIS EQUIPMENT WOULD INCLUDE | | | ANY ROOF MANIFOLDS FOR THE STANDPIPE SYSTEM. | | | | | | 4. NO DETAILS ON FIRESTOPPING METHODS, MATERIALS, OR | | | MANNER PLANNED TO BE USED WHEN PENETRATING RATED FLOORS | | | OR WALLS. | | | | | | 5. NO EQUIPMENT SHALL BE ROUTED THROUGH ANY STAIRWELLS. | | | | | | 6. PLEASE INDICATE RISE, RUN, AND TREAD DEPTH FOR THE | | | PLATFORM STAIRS. WHAT MEASURES WILL BE USED TO PROVIDE | | | SLIP PREVENTION. | | | | | | 7. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. | | | | | | DENIED | | | | | | MIKE CARSILLO, BATTALION CHIEF | | | BUREAU OF FIRE PREVENTION | | | 804-4709 PHONE | | | 804-4774 FAX | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2010-04-05 |
|
|
Cont ID |
|
| Sent By |
lwagner |
Date |
2010-04-05 |
Time |
13:14 |
Rev Time |
0.00 |
| Received By |
lwagner |
Date |
2010-04-05 |
Time |
13:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2009-10-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-09-14 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-09-14 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2009-10-05 11:40:43 | | | | | | | PASSED/PROVISO: | | | | | | REGULATOR SHALL BE LISTED AND HAVE THE REQUIRED OUTLET | | | CAPACITY. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2010-03-24 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2010-03-22 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2010-03-22 |
Time |
15:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2009-09-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-09-02 |
Time |
11:26 |
Sent To |
|
|
| Notes |
| 2009-09-02 13:24:28 | SENT TO C-21. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2009-10-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-09-14 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-09-14 |
Time |
10:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2010-04-08 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2010-04-08 |
Time |
09:57 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2010-04-08 |
Time |
14:13 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2009-09-30 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2009-09-30 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2009-09-30 |
Time |
11:08 |
Sent To |
G |
|
| Notes |
| 2009-10-01 16:51:58 | AMY STELLY | | | PLANNING AND ZONING | | | 561.822 - 1442 | | | | | | THE STORAGE RACK (STEEL PLATFORM) WHICH SUPPORTS THE | | | GENERATOR MUST BE SCREENED IN ACCORDANCE WITH SEC. | | | 94-444 OF THE ZONING CODE. THE SCREENING MUST BE | | | COMPATIBLE WITH THE ARCHITECTURAL CHARACTER OF THE | | | BUILDING. |
|
|