Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-09-08 Cont ID  
Sent By rmcdouga Date 2009-09-08 Time 13:29 Rev Time 0.00
Received By rmcdouga Date 2009-09-08 Time 13:29 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-09-01 Cont ID  
Sent By rmcdouga Date 2009-09-01 Time 09:48 Rev Time 0.00
Received By rmcdouga Date 2009-09-01 Time 09:48 Sent To  
Notes
2009-09-01 10:30:372007 FBC W/2007 REVISIONS
 RE-ROOF
  
 DENIED BY BUILDING
  
 1) THE PRODUCT APPROVAL COVER-SHEETS THAT WERE
 SUBMITTED FOR THE TU PLUS UNDERLAYMENT AND MONIER
 CONCRETE ROOF TILE ARE FOR THE 2004 FLORIDA BUILDING
 CODE WHICH IS NO LONGER IN EFFECT. THE CURRENT CODE IS
 THE 2007 FBC. SUBMIT CURRENT PRODUCT APPROVALS. DCA
 RULE 9B-72.
  
 2) IN ADDITION TO THE FLORIDA PRODUCT APPROVAL COVER
 SHEETS, THE INSTALLATION AND EVALUATION INFORMATION FOR
 THE PRODUCT IS REQUIRED PER DCA RULE 9B-72. SUBMIT THIS
 ADDITIONAL INFORMATION OR THE MIAMI-DADE NOA FOR THE
 PRODUCTS.
  
 3) THE MIAMI-DADE NOA FOR THE POLYGLASS MODIFIED
 ROOFING MATERIAL HAS BEEN CLOSED BY THE MIAMI-DADE CODE
 COMPLIANCE OFFICE. SUBMIT TWO COPIES OF A CURRENT
 PRODUCT APPROVAL. SPECIFY THE FASTENING OPTION AND
 DESIGN PRESSURES FOR THE SYSTEM TO BE INSTALLED. SUBMIT
 RAS 117 CALCULATIONS FOR ENHANCED FASTENING AT CORNER
 AND PERIMETER AREAS. SEE LIMITATIONS ON THE PRODUCT
 APPROVALS.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)805-6714
 [email protected]