| Plan Review Stops For Permit 09080581 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2009-10-14 |
|
|
Cont ID |
|
| Sent By |
jnguyen |
Date |
2009-10-14 |
Time |
11:42 |
Rev Time |
0.00 |
| Received By |
jnguyen |
Date |
2009-10-13 |
Time |
10:13 |
Sent To |
|
|
| Notes |
| 2009-10-14 11:20:59 | 10-14-09: CHERYL HORTON OF PAPA GOT BACK TO ME | | | REGARDING THE ISSUE WITH THE RETAIL TENANT SPACES (A, B | | | & C) WITHIN THE 17-DIGIT CONDO PCN# 74434322170010031 | | | AT 400 N FLAGLER DR # C1 (COMMERCIAL MARINA OF | | | WATERVIEW CONDOMINIUM). THE CONTENT OF HER E-MAIL WAS | | | AS FOLLOWED: | | | | | | "RETAIL SPACE A THRU C IS A PORTION OF COMMERCIAL UNIT | | | C-1 WHICH ENCOMPASSES THE ENTIRE MARINA. THE PCN YOU | | | LISTED IS FOR THE UNIT C1. THERE IS NO SEPARATE LEGAL | | | DESCRIPTION FOR TENANT SPACES A THRU C ON THE TAX ROLL. | | | THIS INFORMATION WAS PROVIDED TO ME FROM GENE POTTER, | | | CONDOMINIUM DEPARTMENT. IF YOU HAVE ANY QUESTIONS, | | | PLEASE CONTACT GENE AT 355-3261." | | | | | | SINCE THE RETAIL TENANT SPACES ARE DIRECTLY A PART OF | | | UNIT # C1, I HAVE ADDED THEM AS EXTENSIONS OFF PCN# | | | 74434322170010031 IN COMMUNITYPLUS (TO BE ABLE TO | | | DIFFERENTIATE THEM). THEY WERE IMPLEMENTED AS FOLLOWED: | | | SEQUENTIAL UNIT RECORD 0002 - 400 N FLAGLER DR # C1 | | | TENANT A, SEQUENTIAL UNIT RECORD 0003 - 400 N FLAGLER | | | DR # C1 TENANT B & SEQUENTIAL UNIT RECORD 0004 - 400 N | | | FLAGLER DR # C1 TENANT C. AS A RESULT, I HAVE MOVED | | | PERMIT# 09080578 FROM THE MAIN LOCATION RECORD OF PCN# | | | 74434322170010031 TO BE INSTEAD REFERENCED TO | | | SEQUENTIAL UNIT RECORD 0002 - 400 N FLAGLER DR # C1 | | | TENANT A. I ALSO MOVED PERMIT# 09080581 TO BE APPLIED | | | INSTEAD TO SEQUENTIAL UNIT RECORD 0003 - 400 N FLAGLER | | | DR # C1 TENANT B. I MADE THE ADJUSTMENTS ON THEIR | | | ORIGINAL PERMIT APPLICATIONS TOO. I RETURNED THE | | | ASSOCIATED DOCUMENTS BACK TO THE B14 & B18 BOXES | | | DOWNSTAIRS. | | | | | | JOHN NGUYEN | | | GIS SUPPORT SPECIALIST | | | CITY OF WEST PALM BEACH | | | MIS DEPARTMENT | | | OFFICE: (561) 822-1239 | | | FAX: (561) 822-1249 | | | [email protected] | | 2009-10-13 13:40:42 | | | | | | | | | | 10-13-09: I CURRENTLY HAVE THE SITE PLANS CHECKED OUT. | | | THE RENOVATION SHOWS THAT THIS PART OF THE WATERVIEW | | | CONDOMINIUM IS BEING DESIGNATED AS THREE DISTINCT | | | TENANT SPACES OF A, B & C. I AM NOT AWARE IF EACH ONE | | | OF THESE ALPHA CHARACTERS HAVE THEIR OWN DISTINCT | | | 17-DIGIT PCN#, SO I CONTACTED CHERYL HORTON OF PAPA | | | WITH THE FOLLOWING MESSAGE: | | | | | | "THE EASTERN PART (DIRECTLY FACING THE DOCK) OF THE | | | WATERVIEW TOWERS CONDOMINIUM IS CURRENTLY BEING | | | RENOVATED WITH TENANT SPACES A, B & C (SHOWN AS PCN# | | | 74434322170010031 AT 400 N FLAGLER DR # C1 ON THE | | | AERIAL). SINCE IT IS THE DEVELOPER'S JURISDICTION TO | | | ASSIGN SUITE ADDRESSES FOR UNITS WITHIN CONDOMINIUMS, I | | | AM NOT AWARE OF THE ASSOCIATED PCN#S FOR TENANT SPACES | | | A & B. DOES # A & B SHARE THE SAME 17-DIGIT CONDO PCN# | | | 74434322170010031 ASSOCIATED WITH # C1 OR DO THEY HAVE | | | THEIR OWN UNIQUE ONES? IS # A & B ALREADY ON FILE AS | | | ONE OF THE UNIT # PH ALPHA CHARACTERS OR ARE THESE PH | | | UNITS UNRELATED (AS SHOWN IN THE PAPA SCREENSHOTS | | | BELOW)?" | | | | | | UNTIL I HEAR BACK FROM CHERYL, I AM NOT SURE IF | | | SUITES/UNITS # A & B SHOULD BE EXTENSIONS OFF PCN# | | | 74434322170010031, HAVE BEEN ASSIGNED NEW 17-DIGIT | | | CONDO PCN#S OR IF THEY WERE ALREADY IN EXISTENCE? |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2009-12-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-12-15 |
Time |
16:47 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2009-12-15 |
Time |
16:47 |
Sent To |
|
|
| Notes |
| 2009-12-15 16:48:05 | BUILDING PLAN REVIEW | | | PERMIT: 09080581 | | | ADD: 400 N FLAGLER / TENANT B | | | CONT: SHAKMAN HOSPITALITY | | | TEL: (561)756-2553 | | | | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | | | | REVISION- REVIEW- 09110611 | | | | | | | | | 1) SHEET A-4/ DETAIL# 1 & M1.01. PLANS INDICATE A | | | PLENUM RETURN. | | | BUILDING APPROVED WITH EXCEPTION! | | | | | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO | | | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE | | | ASSESSMENT OF REINSPECTION FEE(S). | | | | | | PLENUMS- MECHANICAL 602.2.1.5.1, SEPARATION REQUIRED. | | | THE FOAM PLASTIC INSULATION SHALL BE SEPARATED FROM THE | | | PLENUM BY A THERMAL BARRIER COMPLYING WITH SECTION | | | 2603.4 OF THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 2603.4 THERMAL BARRIER. EXCEPT AS PROVIDED FOR IN | | | SECTIONS 2603.4.1 AND 2603.9, FOAM PLASTIC SHALL BE | | | SEPARATED FROM THE INTERIOR OF A BUILDING BY AN | | | APPROVED THERMAL BARRIER OF 0.5-INCH (12.7 MM) GYPSUM | | | WALLBOARD OR EQUIVALENT THERMAL BARRIER MATERIAL THAT | | | WILL LIMIT THE AVERAGE TEMPERATURE RISE OF THE | | | UNEXPOSED SURFACE TO NOT MORE THAN 250??F (120??C) | | | AFTER 15 MINUTES OF FIRE EXPOSURE, COMPLYING WITH THE | | | STANDARD TIME-TEMPERATURE CURVE OF ASTM E 119. THE | | | THERMAL BARRIER SHALL BE INSTALLED IN SUCH A MANNER | | | THAT IT WILL REMAIN IN PLACE FOR 15 MINUTES BASED ON FM | | | 4880, UL 1040, NFPA 286 OR UL 1715. COMBUSTIBLE | | | CONCEALED SPACES SHALL COMPLY WITH SECTION 717. | | | | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2009-12-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-12-01 |
Time |
09:24 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2009-12-01 09:25:12 | BUILDING PROVISO: 2603.4 THERMAL BARRIER. | | | EXCEPT AS PROVIDED FOR IN SECTIONS 2603.4.1 AND 2603.9, | | | FOAM PLASTIC SHALL BE SEPARATED FROM THE INTERIOR OF A | | | BUILDING BY AN APPROVED THERMAL BARRIER OF 0.5-INCH | | | (12.7 MM) GYPSUM WALLBOARD OR EQUIVALENT THERMAL | | | BARRIER MATERIAL THAT WILL LIMIT THE AVERAGE | | | TEMPERATURE RISE OF THE UNEXPOSED SURFACE TO NOT MORE | | | THAN 250??F (120??C) AFTER 15 MINUTES OF FIRE EXPOSURE, | | | COMPLYING WITH THE STANDARD TIME-TEMPERATURE CURVE OF | | | ASTM E 119. THE THERMAL BARRIER SHALL BE INSTALLED IN | | | SUCH A MANNER THAT IT WILL REMAIN IN PLACE FOR 15 | | | MINUTES BASED ON FM 4880, UL 1040, NFPA 286 OR UL 1715. | | | COMBUSTIBLE CONCEALED SPACES SHALL COMPLY WITH SECTION | | | 717. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2009-10-05 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-10-05 |
Time |
11:44 |
Rev Time |
0.75 |
| Received By |
jwitmer |
Date |
2009-10-05 |
Time |
11:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2009-08-27 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-08-27 |
Time |
12:27 |
Rev Time |
1.50 |
| Received By |
jwitmer |
Date |
2009-08-27 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2009-08-27 12:20:58 | BUILDING PLAN REVIEW | | | PERMIT: 09080581 | | | ADD: 400 N FLAGLER DR UNIT C-1 | | | CONT: SHAKMAN HOSPITALITY LLC | | | TEL: (561)756-2553 | | | FL BLD CODE= 2007FLORIDA BUILDING CODE | | | W/ 2009FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | AUGUST 27/2009 | | | | | | | | | 1) PLEASE REVIEW THE LOCATION OF PROJECT ON THE PERMIT | | | APPLICATION VERSES THE PLANS. THE PLANS INDICATE WORK | | | TO BE COMPLETED UNDER THIS PERMIT AS TENAT "B" CREW | | | QUARTERS WHERE-AS THE PERMIT APPLICATION INDICATES | | | TENAT "C-1". PLEASE CORRELATE INFORMATION, 106.1.2 | | | ADDITIONAL INFORMATION REQUIRED. | | | | | | 2) THE ENERGY CALCULATIONS WERE SUBMITTED ON FORM | | | 400A-2008 PLEASE SEE THIS IS FOR WHOLE BUILDING METHOD, | | | PLEASE REVIEW: | | | | | | 13-400.0.B METHOD B, THE BUILDING PRESCRIPTIVE METHOD. | | | THIS IS A PRESCRIPTIVE METHODOLOGY THAT IS ALLOWED FOR | | | SHELL BUILDINGS, RENOVATIONS, CHANGE OF OCCUPANCY, | | | LIMITED OR SPECIAL USE BUILDINGS, AND BUILDING SYSTEM | | | CHANGEOUTS. THE BUILDING ENVELOPE COMPLIES WITH THE | | | STANDARD IF THE PROPOSED BUILDING MEETS OR EXCEEDS THE | | | MANDATORY REQUIREMENTS AND ALL RELEVANT CRITERIA ON | | | FORM 400B OR THEENERGYGAUGE SUMMIT FLA/COM 2008 | | | COMPUTER PRINTOUT. ONLY THE PRESCRIPTIVE ENVELOPE | | | MEASURES OF METHOD B ARE PERMITTED FOR SHELL BUILDINGS. | | | 13-400.0.B.4 RENOVATED BUILDINGS. RENOVATED BUILDINGS | | | SHALL, WHEN APPLICABLE (SEE SECTION 13-202), MEET THE | | | EFFICIENCIES LISTED ON FORM 400B FOR COMPONENTS BEING | | | CHANGED OR SHALL COMPLY WITH THE ENVELOPE OR SYSTEMS | | | CRITERIA IN METHOD B OF ENERGYGAUGE SUMMIT FLA/COM FOR | | | THE COMPONENTS BEING CHANGED. EXISTING BUILDINGS NOT | | | MEETING THE DEFINITION OF A RENOVATION IN WHICH NEW | | | HEATING, COOLING, WATER HEATING, ELECTRICAL OR LIGHTING | | | SYSTEMS ARE INSTALLED SHALL MEET THE MANDATORY MINIMUM | | | EFFICIENCIES LISTED IN THIS CODE FOR THE SYSTEM(S) | | | BEING CHANGED. | | | | | | STARTING AUGUST 21, 2009, THE CONSTRUCTION SERVICES | | | DEPARTMENT WILL BE CLOSED ON FRIDAYS UNTIL FURTHER | | | NOTICE. | | | | | | OPENING HOURS MONDAY - THURSDAY WILL REMAIN AT 8:00 AM | | | - 5:00 PM. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | SURVEY: | | | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2009-10-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-10-20 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-10-20 |
Time |
10:46 |
Sent To |
|
|
| Notes |
| 2009-10-20 10:47:40 | NEW REVISED ELECTRICAL SHEET INSERTED INTO REVISED SET. | | | | | | OTHER REVISED SHEETS SEPARATE FROM ORIGINAL SETS TO BE | | | DONE BY CONTRACTOR PER LUIS MARTINEZ BEFORE PERMIT | | | ISSUANCE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2009-10-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-10-10 |
Time |
12:06 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-10-10 |
Time |
12:06 |
Sent To |
|
|
| Notes |
| 2009-10-10 12:08:29 | ** TEMPORARY FAILED ** | | | | | | TENANT *B* | | | | | | ADDRESS FOR APPLIED LOCATION STILL NEEDS TO BE | | | CORRECTED. THERE IS CURRRENTLY NUMEROUS PERMITS APPLIED | | | AND ISSUED FOR 400 N FLAGLER #C1. THIS INCLUDES PERMITS | | | FOR THREE DIFFERENT DOCKS, ELECTRICAL AND OTHER TENANT | | | SPACES. ADDRESS/SUITE/UNIT EXTENSIONS NEED TO BE ADDED. | | | NOT ALL PERMITS CAN BE ISSUED TO THE SAME | | | TENANT/LOCATION | | | | | | 1) NOTE: AS NOTED ON PREVIOUS REVIEW PLEASE REMOVE OLD | | | SHEETS FROM SETS AND INSERT NEW SHEETS INTO TWO | | | COMPLETE SETS FOR REVIEW AND STAMPING. | | | | | | ADDRESS FOR APPLIED LOCATION STILL NEEDS TO BE | | | COORECTED. THERE IS CURRRENTLY NUMEROUS PERMITS APPLIED | | | AND ISSUED FOR 400 N FLAGLER #C1 FROM THE THREE DIFFENT | | | DOCKS, ELECTRICAL AND OTHER TENANT SPACES. | | | ADDRESS/SUITE/UNIT EXTENSIONS NEED TO BE ADDED. NOT ALL | | | PERMITS CAN BE ISSUED TO THE SAME TENANT/LOCATION. | | | | | | 2) NOTE: BASED ON A CONVERSATION WITH FAE CONSULTING | | | NEW ELECTRICAL SHEETS WERE TO BE BROUGHT IN FOR REVIEW | | | BEFORE ELECTRICAL REVIEW WAS TO BE DONE. THE NEW SHEET | | | E2.01 SUBMITTED ON OCTOBER 2ND WAS INADVERTENTLY NOT | | | SIGNED BY THE ENGINEER OF RECORD. ENGINEER OF RECORD | | | CALLED OFFICE. ALSO SPOKE TO REPRESENTATIVE FROM FAE | | | AND NEW SHEET WILL BE BROUGHT IN AS ENGINEER WAS OUT OF | | | TOWN UNTIL MONDAY THE 12TH OF OCTOBER. SHEET MAY BE | | | BROUGHT IN WITHOUT ANY FEE. | | | SETS OF PLANS NEED TO BE PLACED TOGETHER BY CONTRACTOR. | | | | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2009-09-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-09-18 |
Time |
19:27 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-09-18 |
Time |
19:27 |
Sent To |
|
|
| Notes |
| 2009-09-18 19:27:41 | | | | | | | ** DENIED ** | | | | | | ** REVIEW IS BASED ON PLANS AND SUPPORTING DOCUMENTS | | | SUBMITTED. | | | | | | 1A) NOTE: ADDED, PERMIT APPLICATION STATES TENANT SPACE | | | #C1, HOWEVER PLANS STATE TENANT SPACE *A*. | | | | | | 1) NOTE: IN THE PACKAGE THERE ARE SUPPORTING METHOD *A* | | | WHOLE BUILDING COMPLIANCE ENERGY CALCULATIONS. THIS IS | | | NOT A WHOLE BUILDING BY DEFINITION. PLEASE ALSO SEE | | | THAT PLANS ARE SHOWING A SEPARATE METHOD OF COMPLIANCE. | | | IN FACT PLANS ARE SHOWING PRESCRIPTIVE SPACE BY SPACE | | | METHOD *B*. | | | PLEASE SEE SECTIONS NOTED: | | | | | | THE LIGHTING PLANS SUBMITTED CLEARLY INDICATE METHOD | | | *B*. IN FACT THE PLANS STATE COMPLIANCE FOR SPACE BY | | | SPACE PER 13-415.B.1. PLEASE SEE 13-415.AB.5 OF THE | | | FBC. THIS SECTION CLEARLY STATES THE FOLLOWING. | | | | | | ??? TRADE-OFFS OF INTERIOR LIGHTING POWER ALLOWANCE | | | AMONG PORTIONS OF THE BUILDING FOR WHICH A DIFFERENT | | | METHOD OF CALCULATION HAS BEEN USED IS NOT PERMITTED*. | | | | | | THIS MEANS IT IS NOT PERMISSIBLE TO USE TWO DIFFERENT | | | METHODS TO SHOW COMPLIANCE. THE SUBMITTED INPUT DATA | | | REPORT OF THE METHOD *A* IN BOTH CASES IS NOT COMPLETE. | | | | | | ** THEREFORE COMPLIANCE WITH PRESCRIPTIVE FOR NEW BEING | | | INSTALLED IS REQUIRED TO BE MET. | | | COMPLIANCE FOR METHOD *B* IS SHOWN ON PLANS FOR | | | LIGHTING PERFORMANCE LEVELS AND IS ACCEPTABLE TO THIS | | | OFFICE. | | | 13-415.AB.5, 13-415.B.1, 13-400.0.B.4. PLEASE TAKE A | | | LOOK AT THE LAST SENTENCE FOR * BUILDINGS NOT MEETING | | | THE DEFINITION OF A RENOVATION. | | | | | | ** PLANS INDICATE ALLOWANCES FOR TWO AHU CLOSETS, YET | | | THE PLANS ONLY CONTAIN ONE. | | | | | | ** AT SOME POINT THE FIXTURE K TYPE WILL BE REQUIRED TO | | | BE IDENTIFIED ON FINAL PLANS OF RECORD. | | | | | | | | | ** BASED ON THE ABOVE AND THE INFORMATION NOT YET | | | SHOWN, THE LIGHTING PERFORMANCE CALCULATIONS ARE OVER | | | THE ALLOWANCES OF THE FLORIDA ENERGY CODE. | | | | | | 2) NOTE: ONE OF THE COPIES OF THE SUBMITTED METHOD *A* | | | CALCULATIONS ARE PHOTO-COPIES OF SIGNED DOCUMENTS. THIS | | | IS NOT PERMITTED PER FAC 61G15-23.002, FS 471.025 | | | | | | 3) NOTE: COMPLIANCE FOR NEW LIGHTING CONTROLS BEING | | | INSTALLED SHALL MEET 13-415.AB.1.1,.1.2 AND .1.3. | | | PLEASE SEE 13-415.AB.1.3 SPECIFICALLY AS OTHER LIGHTING | | | SUCH AS TRACK LIGHTING WHICH IS NOT PART OF THE GENERAL | | | LIGHTING SHALL HAVE SEPARATE CONTROLS. | | | PLANS INDICATE SOME SORT OF SWITCHES HOWEVER THERE IS | | | NOT ENOUGH INFORMATION FOR PROPOSED SYSTEM. ARE THESE | | | OVER RIDES? NO INFORMATION ON PROPOSED SYSTEM, TIMES OF | | | OVER RIDES, ETC | | | | | | 4) NOTE: IS THE STAIRS AN EGRESS PATH BY DEFINITION? IF | | | SO, PLEASE SEE NFPA-101 7.8.1.3, 7.9.2.2 FOR MINIMUM | | | LIGHTING LEVELS REQUIRED. | | | | | | 5) NOTE: PLEASE SEE 210.8B2 AS ALL RECEPTACLES 15/20AMP | | | IN KITCHEN AREA SHALL BE GFI/ GFI PROTECTED. THIS IS | | | REQUIRED WHETHER OR NOT RECEPTACLES SERVES A COUNTER | | | SPACE OR DEDICATED EQUIPMENT. | | | | | | 6) NOTE: PLEASE SEE 422.13 FOR STORAGE TYPE OF WATER | | | HEATERS AND REQUIRED MINIMUM 125% LOAD TO BE FIGURED | | | FOR CALCULATIONS OF SERVICES AND FEEDERS. | | | ** SEE 2005 NEC COMMENTARY LAST SENTENCE. THIS IS | | | CONSIDERED A CONTINUOUS LOAD. | | | | | | 7) NOTE: PLEASE ALSO SHOW LOAD CALCULATION COMPLIANCE | | | FOR SIZING SERVICE FEEDERS PER 220.43B | | | | | | 9) NOTE: DISCONNECT FOR EXHAUST FAN IS MISSING. PLANS | | | STATE TO TIME CLOCK FOR CONTROL? | | | PLEASE SEE 430.102B | | | | | | 10) NOTE: DISCONNECT FOR CU DOES NOT MEET 110.26 FOR | | | MINIMUM CLEARANCES. | | | | | | 11) NOTE: PLANS APPEAR TO SHOW HOUSE PANEL IN THIS | | | TENANT SPACE. WHAT IS THIS TENANT SPACE A PART OF? BASE | | | BUILDING? | | | | | | ** LOW VOLTAGE SYSTEMS, INCLUDING FIRE ALARMS ARE NOT | | | INCLUDED. SEPARATE PERMITS AS INDICATED ON PLANS | | | REQUIRED. | | | | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2009-10-20 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-10-20 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-10-20 |
Time |
12:24 |
Sent To |
|
|
| Notes |
| 2009-10-20 12:43:28 | *****PARTIAL APPROVAL****** | | | | | | | | | THE COMMENTS FROM THE PREVIOUS REVIEW HAVE BEEN | | | ADDRESSED; PLAN SHEETS LS-1, A-1.0, A-2.0, E2.01, AND | | | FA1.01 WERE STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2009-09-09 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-09-09 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-09-09 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2009-09-09 15:10:28 | *****DENIED***** | | | | | | 1. THE PROJECT SITE ADDRESS, INCLUDING THE SUITE | | | NUMBER, SHALL BE IN THE TITLE BLOCK OF EACH SUBMITTED | | | PLAN SHEET. | | | | | | 2.. THE PLANS AND PROJECT LOCATION SHALL CORRELATE WITH | | | THE PERMIT APPLICATION AS PER THE CONSTRUCTION SERVICES | | | DEPARTMENT. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING (ON THE APPROPIATE PLAN SHEET) WHERE | | | EACH ITEM WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2009-11-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-11-17 |
Time |
15:10 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-11-17 |
Time |
15:10 |
Sent To |
B |
|
| Notes |
| 2009-11-17 15:11:16 | TTO JIM'S DESK./WRT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2009-10-28 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-10-27 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2009-09-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-09-30 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-09-30 |
Time |
16:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2009-09-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-08-26 |
Time |
14:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2009-09-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-09-18 |
Time |
19:27 |
Rev Time |
|
| Received By |
dpalmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2009-11-09 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-11-09 |
Time |
20:32 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-11-09 |
Time |
20:31 |
Sent To |
|
|
| Notes |
| 2009-11-09 20:32:37 | REVISED M1.01 DELTA 3 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2009-11-02 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-11-02 |
Time |
08:18 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-11-02 |
Time |
08:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2009-10-17 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-10-17 |
Time |
13:34 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-10-17 |
Time |
13:06 |
Sent To |
|
|
| Notes |
| 2009-10-17 13:34:01 | REVIEW #: 2ND | | | ACTION: DENIED | | | | | | FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH | | | PREVIOUS REVIEW COMMENTS AS WELL AS DESIGNER'S WRITTEN | | | RESPONSES FOR THE PURPOSE OF CONTINUITY. | | | | | | 1. PLAN INDICATES 4" ROUND SUPPLY DUCT TO COMPLY WITH | | | EXCEPTION #3 PER FBC-M 607.5.3. FIRST, FLEX DUCTS MAY | | | NOT PENETRATE ANY FIRE RESISTANCE RATED ASSEMBLY IN | | | ACCORDANCE WITH FBC-M 607.7. PLAN STILL SHOWS FLEX DUCT | | | PENETRATING THE RATED WALL. ALSO, ANY DUCT PENETRATION | | | NOT REQUIRED TO HAVE A FIRE DAMPER SHALL COMPLY WITH | | | SECTION 712 OF THE FBC-B PER FBC-M 607.1.1. | | | NOTE: THIS ISSUE CAN BE ELIMINATED BY MOVING THE 4" | | | ROUND TAP FURTHER DOWNSTREAM IN THE SUPPLY TRUNK TO THE | | | OTHER SIDE OF THE RATED WALL, ELIMINATING THE NEED FOR | | | THE 4" SUPPLY DUCT TO PENETRATE ANY RATED ASSEMBLIES. | | | | | | 2. OK | | | | | | 3. PROVIDE BOOSTER FAN MANUFACTURER'S INSTALLATION | | | INSTRUCTIONS AS WELL AS ANY LISTING INFORMATION PER | | | FBC-M 504.6. NO SUCH LISTING COULD BE FOUND. ALSO, | | | PROVIDE DRYER MANUFACTURER'S INSTALLATION INSTRUCTIONS | | | WHICH SHOW PROVISIONS FOR A DRYER BOOSTER FAN AS WELL | | | AS FOR INTERLOCKING OF BOSSTER FAN WITH DRYER. CLOTHES | | | DRYERS SHALL BE EXHAUSTED IN ACCORDANCE WITH THE | | | MANUFACTURER'S INSTRUCTIONS PER FBC-M 504.1. | | | NOTE: IT IS LIKELY THAT A CLOTHES DRYER CAN BE FOUND | | | AND SPECIFIED WHICH WILL ALLOW THE LENGTH OF DRYER DUCT | | | SHOWN ON PLANS WITHOUT THE USE OF A BOSSTER FAN. IF | | | THIS OPTION IS USED, PROVIDE THE DRYER MANUFACTURER'S | | | INSTRUCTIONS WHICH SHOW THE ALLOWABLE DUCT LENGTH IN | | | ACCORDANCE WITH FBC-M 504.6.1. | | | | | | 4 THROUGH 8: OK | | | | | | 9. THE OCCUPANT LOADS AND VENTILATION RATES SHOWN ON | | | PAGE M2.01 VENTILATION CALCULATIONS DO NOT CORRESPOND | | | WITH THE VENTILATION REQUIREMENTS BASED ON ASHRAE | | | 62.1-2004 TABLE 6-1. THE BAR, LOUNGE, FOYER AND | | | BILLIARD AREAS SHALL BE CALCULATED WITH AN OCCUPANT | | | LOAD OF 100 PEOPLE PER 1000 SQUARE FEET AND AT A | | | VENTILATION RATE OF 7.5 CFM/PERSON PLUS 0.18 CFM/SQ FT | | | OF AREA. | | | NOTE: WHILE IT IS UNDERSTOOD THAT VENTILATION | | | CALCULATIONS SHOULD NOT BE PERFORMED BASED ON BUILDING | | | CODE OCCUPANT LOADS, IT IS UNNREASONABLE TO PROVIDE | | | VENTILATION CALCULATIONS FOR 22 PEOPLE WHEN THE LIFE | | | SAFETY PLAN SHOWS AN OCCUPANT LOAD OF 121 PEOPLE. | | | | | | 10. BASED ON COMMENT #9 ABOVE, IT IS LIKELY THAT | | | MOTORIZED DAMPERS WILL BE REQUIRED ON OUTSIDE AIR | | | INTAKES PER FBC-B 13-409.AB.3.3. ALSO, PROVIDE UPDATED | | | COOLING LOAD CALCULATIONS SHOWING INCREASED VENTILATION | | | RATES AND PROPERLY SIZED APPLIANCES IN ACCORDANCE WITH | | | FBC-M 312.1 AND FBC-B 13-407.AB.1. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2009-09-08 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-09-08 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-09-03 |
Time |
16:59 |
Sent To |
|
|
| Notes |
| 2009-09-08 10:18:30 | REVIEW #: 1ST | | | ACTION: DENIED | | | | | | FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | 1. FLOOR PLAN SHOWS SEVERAL DUCTS PENETRATING RATED | | | WALL ASSEMBLIES WITHOUT PROTECTION. EXAMPLES: 4 INCH | | | SUPPLY AND EXHAUST AT STAFF RESTROOM B14, 10X3 EXHAUST | | | AT GAME ROOM B03. THESE ARE EXAMPLES AND NOT INTENDED | | | TO BE AN EXHAUSTIVE LIST. CHECK ALL WALL PENETRATIONS | | | FOR REQUIRED PROTECTION OF PENETRATIONS IN ACCORDANCE | | | WITH FBC-M 607.1. | | | | | | 2. AHU 3 AND AHU 4 SHARE A COMMON RETURN AIR PLENUM. | | | EACH UNIT SHALL BE PROVIDED WITH DUCT SMOKE DETECTORS | | | IN ACCORDANCE WITH FBC-M 606.2.2. THE DUCT SMOKE | | | DETECTORS SHALL BE CONNECTED TO THE BUILDING FIRE ALARM | | | SYSTEM IN ACCORDANCE WITH FBC-M 606.4.1. | | | | | | 3. PLANS APPEAR TO SHOW THE DRYER EXHAUST DUCT | | | CONNECTING TO AN EXTERIOR, WALL MOUNTED EXHAUST FAN. AN | | | EXHAUST FAN USED FOR THIS PURPOSE MUST BE LISTED AND | | | LABELED AS A DRYER BOOSTER FAN IN ACCORDANCE WITH FBC-M | | | 504.6. ALSO, THE DRYER MANUFACTURER'S INSTALLATION | | | INSTRUCTIONS MUST ALSO INCLUDE THE USE OF AN ADDITIONAL | | | FAN (AS WELL AS THE INTERLOCK OF FAN WITH DRYER AS | | | CALLED FOR ON THE FAN SCHEDULE) IN ACCORDANCE WITH | | | FBC-M 504.1. | | | | | | 4. THE CLOTHES DRYER EXHAUST DUCT IS SHOWN PENETRATING | | | A RATED WALL WITH A FIRE DAMPER. FIRE DAMPERS AND ANY | | | SIMILAR DEVICES THAT WILL OBSTRUCT THE EXHAUST FLOW | | | SHALL BE PROHIBITED IN CLOTHES DRYER EXHAUST DUCTS IN | | | ACCORDANCE WITH FBC-M 504.2. THIS DUCT PENETRATION MAY | | | BE PROTECTED AS A THROUGH-PENETRATION IN ACCORDANCE | | | WITH FBC-B SECTION 712. | | | | | | 5. THE DRYER EXHAUST DUCT SHALL NOT BE LOCATED IN A | | | PLENUM IN ACCORDANCE WITH FBC-M 601.5. | | | | | | 6. OUTDOOR EXHAUST FANS AND CONDENSING UNITS SHALL BE | | | DESIGNED AND INSTALLED FOR WIND RESISTANCE IN | | | ACCORDANCE WITH FBC-M 301.12. PROVIDE MANUFACTURER'S | | | DATA FOR FANS AND CONDENSERS SHOWING THESE APPLIANCES | | | ARE DESIGNED FOR WIND RESISTANCE. PROVIDE | | | MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR WIND | | | RESISTANT INSTALLATION IF APPLICABLE. THERE IS NO | | | INSTALLATION DETAIL ON PLANS FOR THE FANS. | | | NOTE: THE CONDENSER INSTALLATION DETAIL REFERENCES | | | FBC-M 301.13.1, WHICH WAS A PRESCRIPTIVE METHOD OF | | | INSTALLATION IN THE 2004 FBC FOR R-3 OCCUPANCIES ONLY. | | | THIS PRESCRIPTIVE METHOD IS NOT APPLICABLE. AN | | | ENGINEERED DESIGN IS REQUIRED. THE MANUFACTURER'S WIND | | | CERTIFICATION MAY CONTAIN SPECIFIC REQUIREMENTS FOR A | | | WIND RESISTANCE COMPLIANT INSTALLATION. | | | | | | 7. SUBMIT PRODUCT APPROVALS FOR WALL LOUVERS IN | | | ACCORDANCE WITH FAC RULE 9B-72. | | | | | | 8. EMPLOYEE LOUNGE B13 IS SEPARATED FROM THE AHU BY A | | | 1-HOUR FULL HEIGHT PARTITION. SHOW HOW BALANCED RETURN | | | IS TO BE ACHIEVED IN THIS AREA IN ACCORDANCE WITH FBC-M | | | 601.4. | | | | | | 9. THE VENTILATION CALCULATIONS CLASSIFY ALL AREAS | | | SERVED BY THESE SYSTEMS AS "OFFICE." THIS IS NOT | | | CORRECT. THESE VENTILATION SYSTEMS SHALL BE DESIGNED TO | | | HAVE THE CAPACITY TO SUPPLY THE MINIMUM OUTDOOR AIRFLOW | | | RATE DETERMINED IN ACCORDANCE WITH TABLE 403.3 BASED ON | | | THE OCCUPANCY OF THE SPACE AND THE OCCUPANT LOAD. THE | | | FLOOR PLAN SHOWS SEVERAL DIFFERENT AREAS WITH DIFFERENT | | | VENTILATION REQUIREMENTS, SUCH AS (EXAMPLES) THE BAR, | | | GAME ROOM, LOUNGE AND FITNESS CENTER. PROVIDE | | | SPACE-BY-SPACE VENTILATION CALCULATIONS SHOWING THE | | | CORRECT OCCUPANCY CLASSIFICATION, OCCUPANT LOAD AND | | | VENTILATION RATE FOR EACH SPACE. | | | NOTE: COOLING LOADS MAY ALSO BE AFFECTED BY INCREASED | | | VENTILATION. | | | | | | 10. NOTE ON PAGE M2.01 CALLS FOR MANUAL VOLUME DAMPER | | | IN LIEU OF A MOTORIZED DAMPER ON THE OUTSIDE AIR | | | INTAKES. ACCORDING TO FBC-B 13-409.AB.3.3, A GRAVITY | | | OPERATED DAMPER MAY BE USED IN LIEU OF A MOTORIZED | | | DAMPER IF THE INTAKE IS LESS THAN 300 CFM. IN ADDITION | | | TO THE GRAVITY DAMPER, A MANUAL VOLUME DAMPER IS | | | REQUIRED IN ACCORDANCE WITH FBC-B 13-409.AB.1.1. | | | NOTE: VENTILATION QUANTITIES ARE LIKELY TO EXCEED 300 | | | CFM ONCE VENTILATION RATES ARE RECALCULATED PER COMMENT | | | #9 ABOVE. IF SO, PROVIDE MOTORIZED VOLUME DAMPERS IN | | | ACCORDANCE WITH FBC-B 13-409.AB.3.3. | | | | | | ENERGY CALCULATIONS: THE METHOD A COMPLIANCE FORM | | | SUBMITTED WILL NOT BE REVIEWED FOR THIS PROJECT. THIS | | | IS AN ALTERATION TO A PORTION OF AN EXISTING BUILDING | | | WHICH DOES NOT MEET THE DEFINITION OF A RENOVATION. AN | | | ENERGY CODE COMPLIANCE FORM IS NOT REQUIRED. THE | | | DESIGNER IS ONLY REQUIRED TO DEMONSTRATE COMPLIANCE | | | WITH THE PRESCRIPTIVE MINIMUM REQUIREMENTS FOR NEW | | | SYSTEMS BEING INSTALLED IN ACCORDANCE WITH FBC-B | | | 13-101.6. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
N |
Date |
2009-12-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-12-15 |
Time |
11:16 |
Rev Time |
|
| Received By |
kstevens |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2009-10-29 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-10-29 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-10-29 |
Time |
14:52 |
Sent To |
|
|
| Notes |
| 2009-10-29 14:53:40 | PASSED/PROVISO: | | | GRAB BARS ON THE BACK WALL OF THE SHOWER SHALL COMPLY | | | WITH FIGURE 37 OF CHAPTER 11 FBC-BUILDING. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2009-10-01 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-10-01 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-10-01 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2009-10-01 14:00:16 | PASSED/PROVISO: | | | GRAB BARS ON THE BACK WALL OF THE SHOWER SHALL COMPLY | | | WITH FIGURE 37 OF CHAPTER 11 FBC-BUILDING. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2009-08-26 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-08-26 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-08-26 |
Time |
16:29 |
Sent To |
|
|
| Notes |
| 2009-08-26 17:03:05 | DENIED | | | REFERENCE: | | | FBC-2007 PLUMBING | | | FBC-2007 CHAPTER 1 | | | FBC-2007 CHAPTER 11 | | | | | | 1. SUBMIT A DETAIL FOR THE DRINKING FOUNTAIN SHOWING | | | COMPLIANCE WITH SECTION 11-4.15 WITH ALL SUBSECTIONS AS | | | WELL AS SECTION 11-4.1.3(10)(A) PROVISIONS FOR THOSE | | | WHO HAVE DIFFICULTY BENDING OR STOOPING. | | | | | | 2. SHT A-3.0 SHOW COMPLIANCE FOR THE FOLLOWING | | | ACCESSIBILITY REQUIREMENTS: | | | ___FOR W/C'S | | | A. 11-4.16.3 HEIGHT | | | B. 11-4.16.5 FLUSH CONTROLS | | | C. FIG. 28 W/C SHALL BE 1'6" OFF THE WALL TO THE | | | CENTERLINE OF THE FIXTURE | | | ___FOR LAVS | | | A. 11-4.19.4 EXPOSED PIPES & SURFACES | | | B. 11-4.19.5 FAUCETS | | | C. 1104.19.3 LAV SHALL BE MINIMUM 15" OFF THE WALL TO | | | THE CENTERLINE OF THE FIXTURE. | | | ____FOR SHWRS | | | A. 11-4.21.2 CLEAR FLOOR SPACE | | | B. 11-4.21.4 GRAB BARS | | | | | | 3. SHT P1.01 KEY NOTES #10 THE CONDENSATE SHALL BE | | | PIPED OUT SEPARATELY OUT OF THE BUILDING AND DRAIN INTO | | | THE STORM LINE WITH A RELIEF VENT, (GOOSENECK), | | | INSTALLED AS THE CONDENSATE EXITS THE BUILDING, OR TO A | | | DRYWELL OR A PLANTED AREA. THIS SHALL BE CORRECTED ON | | | SHT P-2.01 RISER #1 RAIN WATER AS WELL. SECTION | | | 314.2.1. | | | | | | 4. SHT P-2.01 RISER #1 RAIN WATER SHOW ALL PIPE SIZES | | | AND INDICATE THE SQUARE FOOTAGE BEING DRAIN BY EACH | | | DRAIN. TABLE 1106.3. | | | | | | 5. SHTS P-1.01 & P-2.01 A FLOOR DRAIN IS NOT AN | | | APPROVED INDIRECT WASTE RECEPTOR FOR THE ICE MACHINE. A | | | FLOOR SINK OR HUB DRAIN IS REQUIRED PER SECTIONS 802.3 | | | & 802.3.2. | | | | | | 6. SHT P-2.01 RISER #3 WATER. THE WATER HAMMER | | | ARRESTORS SHALL BE LOCATED NEAR THE FIXTURE IN AN | | | "EFFECTIVE RANGE" FOR THE WASH MACHINE, NOT IN THE | | | CEILING AS SHOWN. PDI-WH 201. | | | | | | 7. SHT P-2.01 RISER #2 SANITARY. 3 INCH PIPE IS | | | REQUIRED FOR THE WASH MACHINE STACK AND BRANCH DRAIN | | | PER SECTION 406.3. PLEASE INDICATE ON RISER. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2009-09-11 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2009-09-11 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2009-09-11 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2009-09-11 16:11:17 | INTERIOR IMPROVMENTS ONLY. NO ZONING REQUIRED. |
|
|