Plan Review Details - Permit 09080556
Plan Review Stops For Permit 09080556
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-09-16 Cont ID  
Sent By jwitmer Date 2009-09-16 Time 13:45 Rev Time 0.00
Received By kstevens Date 2009-09-17 Time 07:05 Sent To  
Notes
2009-09-16 13:50:19WOMENS STALL: 11-4.1.6(J) EXCEPTION: TECHNICALLY
 INFESIBLE OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-08-26 Cont ID  
Sent By jwitmer Date 2009-08-26 Time 17:29 Rev Time 0.50
Received By jwitmer Date 2009-08-26 Time 17:00 Sent To  
Notes
2009-08-26 17:25:00BUILDING PLAN REVIEW
 PERMIT: 09080556
 ADD: 222 LAKEVIEW 1ST FL RESTROOMS
 CONT: HOLT LEE CONSTRUCTION
 TEL: (954)725-4881
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW
 ACTION: DENIED
  
 1) WOMEN'S RESTROOM NEEDS TO COMPLY WITH SECTION
 11-4.1.6(1) (B) F EXISTING ELEMENTS, SPACES, OR COMMON
 AREAS ARE ALTERED, THEN EACH SUCH ALTERED ELEMENT,
 SPACE, FEATURE, OR AREA SHALL COMPLY WITH THE
 APPLICABLE PROVISIONS OF SECTION 11-4.1.1 TO SECTION
 11-4.1.3, MINIMUM REQUIREMENTS FOR NEW CONSTRUCTION.
 PLEASE SEE 11-4.17.3 SIZE AND ARRANGEMENT EXCEPTION FOR
 NEW CONSTRUCTION:
  
 EXCEPTION: NEW CONSTRUCTION.
  
 (1) THE STANDARD ACCESSIBLE RESTROOM STALL SHALL
 CONTAIN AN ACCESSIBLE LAVATORY WITHIN IT, THE SIZE OF
 SUCH LAVATORY TO BE NOT LESS THAN 19 INCHES WIDE BY 17
 INCHES (483 MM BY 432 MM) DEEP, NOMINAL SIZE, AND WALL
 MOUNTED. THE LAVATORY SHALL BE MOUNTED SO AS NOT TO
 OVERLAP THE CLEAR FLOOR SPACE AREAS REQUIRED BY SECTION
 11-4.17 [SEE FIGURE 30(A) AND FIGURE 30(E)] AND TO
 COMPLY WITH SECTION 11-4.19 OF THE CODE. SUCH
 LAVATORIES SHALL BE COUNTED AS PART OF THE REQUIRED
 FIXTURE COUNT FOR THE BUILDING.
  
 (2) THE ACCESSIBLE WATER CLOSET SHALL BE LOCATED IN THE
 CORNER, DIAGONAL TO THE DOOR.
  
 INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 STARTING AUGUST 21, 2009, THE CONSTRUCTION SERVICES
 DEPARTMENT WILL BE CLOSED ON FRIDAYS UNTIL FURTHER
 NOTICE.
  
 OPENING HOURS MONDAY - THURSDAY WILL REMAIN AT 8:00 AM
 - 5:00 PM.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
 SURVEY:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.
  
 MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF
 FLORIDA SAVING LIVES AND PROPERTY SINCE 1953
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2009-08-24 Cont ID  
Sent By btrobaug Date 2009-08-24 Time 08:24 Rev Time 0.00
Received By btrobaug Date 2009-08-24 Time 07:22 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2009-08-25 Cont ID  
Sent By mawillia Date 2009-08-25 Time 11:58 Rev Time 0.00
Received By mawillia Date 2009-08-25 Time 11:43 Sent To  
Notes
2009-08-25 11:56:44*****APPROVED*****
  
 PLAN SHEETS A1.1, E1, & E2 WERE STAMPED, INITIALED, AND
 DATED.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-09-16 Cont ID  
Sent By lmartine Date 2009-09-16 Time 10:43 Rev Time 0.00
Received By lmartine Date 2009-09-16 Time 10:43 Sent To  
Notes
2009-09-16 10:44:47*******************EXPEDITED********************
 GAVE TO JIM

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2009-08-27 Time   Rev Time 0.00
Received By lmartine Date 2009-08-20 Time 17:11 Sent To  
Notes
2009-08-20 17:22:38B-10

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2009-08-27 Cont ID  
Sent By rregueir Date 2009-08-27 Time 18:53 Rev Time 0.00
Received By rregueir Date 2009-08-27 Time 18:53 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2009-09-17 Cont ID  
Sent By kstevens Date 2009-09-17 Time 07:06 Rev Time 0.00
Received By kstevens Date 2009-09-17 Time 07:06 Sent To  
Notes
2009-09-17 07:07:31PER SECTION 11-4.1.6(J) TECHNICALLY INFEASIBLE TO HAVE
 COMPLIANT STALL IN WOMENS TOILET ROOM.

Review Stop P PLUMBING
Rev No 1 Status F Date 2009-08-24 Cont ID  
Sent By kstevens Date 2009-08-24 Time 17:20 Rev Time 0.00
Received By kstevens Date 2009-08-24 Time 17:20 Sent To  
Notes
2009-08-24 17:36:02DENIED
 REFERENCE:
 FBC-2007 PLUMBING
 FBC-2007 BUILDING
 FBC-2007 EXISTING BUILDING
 FBC-2007 CHAPTER 11
  
 1. SUBMIT CALCULATIONS FOR MINIMUM FACILITIES PER
 TABLES 104.1.1, (BLDG) & 403.1, (PLMG). INDICATE THE
 TOTAL SQUARE FOOTAGE OF THE FIRST FLOOR AND SHOW THE
 REQUIRED FIXTURES FOR THE FLOOR. TWO FIXTURES, (WATER
 CLOSETS HAVE BEEN DELETED).
  
 2. SHT A1.1 THE ACCESSIBLE TOILET STALL IN THE WOMEN'S
 TOILET ROOM DOES NOT COMPLY WITH FIGURE 30E. A LAV IS
 REQUIRED IN THE STALL. PER SECTION 11-4.1.6(1)(B) IF
 EXISTING ELEMENTS, SPACES, OR COMMON AREAS ARE ALTERED,
 THEN EACH SUCH ALTERED ELEMENT, SPACE, FEATURE, OR AREA
 SHALL COMPLY WITH THE APPLICABLE PROVISIONS OF SECTION
 11-4.1.1 TO SECTION 11-4.1.3, MINIMUM REQUIREMENTS FOR
 NEW CONSTRUCTION.
  
 3. SHT A2.1 DETAIL A1 DOES NOT COMPLY WITH FIGURE 31
 FOR THE CLEARANCE. THE BOTTOM OF THEREMOVABLE PANEL
 SHALL BE A MAXIMUM 6 INCHES OFF THE WALL.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  

Review Stop Z ZONING
Rev No 1 Status N Date 2009-08-27 Cont ID  
Sent By aaponte Date 2009-08-27 Time 08:51 Rev Time 0.00
Received By aaponte Date 2009-08-27 Time 08:51 Sent To  
Notes
***NONE***