Plan Review Details - Permit 09080357
Plan Review Stops For Permit 09080357
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-10-22 Cont ID  
Sent By shill Date 2009-10-22 Time 16:53 Rev Time 0.00
Received By shill Date 2009-10-22 Time 16:53 Sent To  
Notes
2009-10-22 16:53:23REVISION OK
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2009-09-17 Cont ID  
Sent By shill Date 2009-09-17 Time 15:44 Rev Time 0.00
Received By shill Date 2009-09-17 Time 15:44 Sent To  
Notes
2009-09-17 15:47:36****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. IT APPEARS THAT THE 2004 AAF GUIDE WAS USED; 2007
 AAF GUIDE REQUIRED EFFECTIVE MARCH 1, 2009, FBC 35.
  
 2. IT APPEARS THAT CALCULATIONS WERE PERFORMED TO
 DETERMINE SPANS FOR EXPOSURE C. THERE ARE CHARTS IN THE
 APPENDIX AT THE BACK OF THE AAF GUIDE WHICH ARE TO BE
 USED FOR EXPOSURE C. PLEASE EITHER SUBMIT CORRECT
 CHARTS OR EXPLAIN DESIGN.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU NEED ASSISTANCE.
 THE RESUB MAY BE SUBMITTED VIA EMAIL.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2009-09-01 Cont ID  
Sent By mcruz Date 2009-09-02 Time 10:14 Rev Time 0.00
Received By shill Date 2009-09-01 Time 13:26 Sent To  
Notes
2009-09-01 13:30:06****PROVISOS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 1. ISSUED AT CONTRACTOR'S RISK
  
 2. REVISION REQUIRED - THIS JOB IS LOCATED IN EXPOSURE
 C. (SEE ASCE7-05, FBC R301)
 REVISE PLAN FOR EXPOSURE C CONDITIONS AND SUBMIT ALL
 RELEVANT DETAILS/CHARTS FROM AAF GUIDE
  
 EXPOSURE B DETAILS WHICH WERE SUBMITTED ARE BEING
 RETURNED TO CONTRACTOR. THEY MUST BE REPLACED OR
 SUPPLEMENTED WITH CHARTS/DETAILS FOR EXPOSURE C DESIGN
 PRESSURES.
  
 3. SUBMIT A STRUCTURAL DETAIL SHOWING HOW THE ALUMINUM
 WILL BE ATTACHED TO THE STEEL COLUMNS AND HOW THE ISSUE
 OF DISSIMILAR METALS WILL BE ADDRESSED.
  
 AN INSPECTION HOLD HAS BEEN PLACED ON THIS PROJECT.
 REVISED PLANS ARE TO BE SUBMITTED PRIOR TO FIRST
 INSPECTION.
  
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2009-09-01 Cont ID  
Sent By shill Date 2009-09-01 Time 17:58 Rev Time 0.00
Received By shill Date 2009-09-01 Time 17:58 Sent To  
Notes
2009-08-14 09:43:55OK PER F MITTNER 8-14-09
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-10-22 Cont ID  
Sent By kstevens Date 2009-10-22 Time 10:45 Rev Time 0.00
Received By kstevens Date 2009-10-22 Time 10:45 Sent To  
Notes
2009-10-22 10:46:02SENT TO SHILL.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-09-01 Cont ID  
Sent By shill Date 2009-09-01 Time 13:30 Rev Time 0.00
Received By shill Date 2009-08-17 Time 16:04 Sent To Z
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2009-08-27 Cont ID  
Sent By shill Date 2009-08-27 Time 13:30 Rev Time 0.00
Received By mcruz Date 2009-08-27 Time 16:28 Sent To B
Notes
2009-08-27 16:59:47ROUTED TO MISC #2