| Plan Review Stops For Permit 09080335 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2009-09-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-09-17 |
Time |
17:02 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2009-09-17 |
Time |
17:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2009-08-20 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-08-20 |
Time |
07:55 |
Rev Time |
1.50 |
| Received By |
jwitmer |
Date |
2009-08-20 |
Time |
07:54 |
Sent To |
|
|
| Notes |
| 2009-08-20 08:26:51 | BUILDING PLAN REVIEW | | | PERMIT: 09080335 | | | ADD: 222 LAKEVIEW AV# 100 | | | CONT: MENEMSHA DEVELOPMENT | | | TEL: (718)337-9012X247 | | | FL BLD CODE= 2074 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | AUGUST 20/2009 | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1)PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER | | | MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC | | | BUILDING WITH 2009 SUPPLEMENTS. | | | | | | PLANS WILL ALSO BE REVIEWED TO THE 2007 EXISTING | | | BUILDING CODE W/ 2009 SUPPLEMENTS, PLEASE INDICATE TO | | | WHAT LEVEL ALTERATION WILL BE COMPLETED UNDERTHIS | | | PERMIT. | | | 401.4 A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE | | | OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO | | | SECTIONS 403, 404 AND 405 OF THIS CODE. | | | | | | 2) SHEET A.0 / CODE DATA & CORRECTIONS; | | | 2A) LOCATION OF PROJECT, WEST PALM BEACH, FL | | | | | | 2B) CONSTRUCTION TYPE: TYPE I-A NOT A V-B | | | | | | 2C) BUILDING HEIGHT NOT A MULTI-STORY BUT HIGHRISE | | | SECTION 403 | | | | | | 2D) FIRE RESISTANCE RATINGARE LISTED FOR A V-B CORRECT | | | TO A TYPE I-A | | | | | | 3) SHEET A3.0 | | | | | | 3A) DETAIL# 4 INDICATES THE USE OF PLYWOOD BLOCKING | | | BETWEEN STUDS. PLEASE REVIEW 603.3.1.1USE OF FIRE | | | RETARDANT TREATED WOOD (11) BLOCKING. | | | | | | 3B) DETAIL# 5 INDICATESTHE USE OF WOOD STUDS, | | | 603.1.1(1.1) | | | | | | 4) SHEET A3.3 DETAILS 3&4 INDICATE THE USE OF 1/2" | | | PLYWOOD PANEL LAMINATES PLEASE REVIEW 803.4.1, 803.4.2 | | | & 803.4.4.PLEASE PROVIDE COMPLIANCE WITH ONE OF THESE | | | SECTIONS. | | | | | | 5) ATM MACHINES INDICATE ON SHEET A1.0 COMMENT NUMBER | | | 42 ATM TO BE REMOVED AND OR RELOCATED, SHEET A1.1 | | | DETAIL 5G&H/ A3.1 INDICATES THE WIDTH OF THE MACHINE. | | | BETWEEN DETAILS A&B IT INDICATES THE MACHINES ARE ADA | | | COMPLIANT, PLEASE PROVIDE THE HEIGHT OF |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2009-11-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-11-16 |
Time |
12:04 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-11-16 |
Time |
11:46 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2009-10-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-10-16 |
Time |
09:00 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-10-16 |
Time |
07:33 |
Sent To |
PC |
|
| Notes |
| 2009-10-16 09:00:48 | ** PROVISO ** | | | | | | ** REVISE PLANS BEFORE ROUGH INSPECTION. REVISED PLANS | | | WILL BE REQUIRED TO BE REVIEWED BY THIS OFFICE, STAMPED | | | AND ON-SITE FOR FIRST ROUGH ELECTRICAL INSPECTION. | | | | | | 1) NOTE: COMPLIANCE FOR CHAPTER 13 FOR NEW CONTROLS | | | MEETING PRESCRIPTIVE REQUIREMENTS MUST BE MET. BASED ON | | | REVISED PLANS THERE IS A NEW TIME CLOCK BEING ADDED | | | WHICH IS OK HOWEVER ANY OVER RIDE CONTROLS SHALL | | | AUTOMATICALLY SHUT OFF LIGHTING IN THE MAXIMUM TIMED | | | PERMITTED BY THE FBC. | | | AS THE SYMBOL LEGEND INDICATES THE OVER RIDES AS | | | STANDARD SINGLE POLE SWITCHES, THIS WOULD NOT MEET | | | CODE. BASED ON THE PLANS AN OCCUPANT COULD OVER RIDE | | | TIME CLOCK, LEAVE THE BUILDING AND LIGHTING WOULD STAY | | | ON INDEFINITELY. | | | PLEASE ALSO SEE SEPARATE SPACES SUCH AS ANY OFFICE OR | | | SPACE WITH FLOOR TO CEILING HEIGHT PARTITIONS. SEPARATE | | | SPACE REQUIREMENTS HAVE BEEN REQUIRED IN THE LAST 8 | | | CODE REVISIONS/ADOPTIONS. | | | SEE TELLER AREA FOR NEW DEVICE BEING INSTALLED. BASED | | | ON SYMBOL LEGEND THIS IS A SINGLE POLE SWITCH WHICH | | | WOULD LEAVE LIGHTS ON. | | | PLEASE SEE 13-415.AB.1 | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2009-09-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-09-17 |
Time |
19:23 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-09-17 |
Time |
19:23 |
Sent To |
|
|
| Notes |
| 2009-09-17 19:23:57 | ** DENIED 2ND REVIEW ** | | | | | | ** SAME NOTES FROM PREVIOUS REVIEW | | | | | | | | | 1) NOTE: PLEASE PROVIDE LIGHTING CONTROLS MEETING | | | MINIMUM PRESCRIPTIVE REQUIREMENTS OF THE FLORIDA | | | BUILDING CODE CHAPTER 13. 13-415.AB.1.1,.1.2 AND .1.3. | | | ONLY NEW LIGHTING CONTROLS BEING INSTALLED ARE REQUIRED | | | TO MEET PRESCRIPTIVE. | | | PLANS INDICATE NEW SINGLE POLE SWITCH BANK HOWEVER THIS | | | IS A TENANT SPACE IN A BUILDING GREATER THAN 5K SQ FT. | | | | | | 2) NOTE: PLEASE SUBMIT LIGHTING PERFORMANCE | | | CALCULATIONS MEETING FBC 13-415.AB.5, 13-415.B.1. MUST | | | SHOW THAT THE NEW LIGHTING BEING ADDED TO OTHER | | | EXISTING LIGHTING DOES NOT EXCEED MAXIMUM ALLOWANCES AS | | | STATED IN SPACES. | | | ** PLEASE CALL TO GO OVER ON HOW TO SHOW CODE | | | COMPLIANCE. PLEASE SEE CODE SECTIONS AS NOTED. | | | | | | 3) NOTE: PLANS STATE THE 2008 NFPA-70 ( NEC) HOWEVER | | | THE 2008 NEC HAS NOT YET BEEN ADOPTED BY THE STATE. IF | | | THIS WAS THE ONLY ITEM PLANS WOULD HAVE BEEN REDLINED | | | FOR THIS. | | | THERE IS NOT NEED TO REPRINT COVER SHEETS TO MAKE THESE | | | CORRECTIONS. | | | | | | 4) NOTE: PLANS DO NOT SHOW ANY INFORMATION FOR ADA | | | COMPLIANCE FOR HORN, HORN/STROBE DEVICES. | | | PLEASE SEE 11-4.28, .1,.2 AND .3. | | | | | | | | | ** AS STATED ABOVE. PLEASE CALL TO GO OVER ANY | | | COMMENTS. | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2009-09-01 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2009-08-27 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
MCARSILL |
Date |
2009-09-01 |
Time |
10:54 |
Sent To |
|
|
| Notes |
| 2009-08-27 07:08:03 | 222 LAKEVIEW AVENUE, SUITE 100 | | | PERMIT # 09080335 AND 09080337 | | | | | | 1. SEVERAL ERRORS EXIST IN CODE DATA BOX ON PAGE A.0.0 | | | | | | 2. CONSTRUCTION, DEMOLITION, AND RENOVATION TO COMPLY | | | WITH NFPA 241. | | | | | | 3. DEBIRS SHALL BE REMOVED FROM THE SITE DAILY. | | | | | | 4. SEPARATE PLANS AND PERMITS REQUIRED FOR FIRE | | | SPRINKLER SYSTEM REMODEL. | | | | | | 5. ALL ELECTRICAL WORK TO COMPLY WITH NFPA 70, THE | | | NATIONAL ELECTRIC CODE. | | | | | | 6. NO FIRE ALARM INITIATING OR SIGNALING APPLIANCES | | | LOCATED ON THE DRAWINGS. | | | | | | 7. SEPARATE PLANS AND PERMITS REQUIRED FOR ANY FIRE | | | SPRINKLER SYSTEM REMODEL. | | | | | | DENIED | | | | | | MIKE CARSILLO, BATTALION CHIEF | | | BUREAU OF FIRE PREVENTION | | | 804-4709 PHONE | | | 804-4774 FAX |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2009-10-05 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-10-05 |
Time |
16:02 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-10-05 |
Time |
15:32 |
Sent To |
|
|
| Notes |
| 2009-10-05 16:01:54 | *****APPROVED***** | | | | | | | | | PLAN SHEETS A1.1, A1.2, E1.0, E3.0, AND FP1.0 WERE | | | STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2009-09-01 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-09-01 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-09-01 |
Time |
10:55 |
Sent To |
|
|
| Notes |
| 2009-09-01 11:01:42 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2007 FLORIDA BUILDING CODE, 2009 REVISIONS, 2005 | | | NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | | NONCOMPLIANT WITH THE FOLLOWING: | | | | | | THESE COMMENTS ARE FROM SHEET E1.0 | | | | | | 1} PLEASE INDICATE THE CODE CYCLES THIS PROJECT WAS | | | DESIGNED UNDER. 2007 FBC, 2005 NEC ETC. ADD TO NOTES | | | FOR CLARITY IN THE FIELD AND COMPLIANCE WITH 106.1.3 | | | FBC AS AMENDED. | | | | | | 2} 13-415.AB.1.2 SPACE CONTROL. EACH SPACE ENCLOSED BY | | | CEILING-HEIGHT PARTITIONS SHALL HAVE AT LEAST ONE | | | CONTROL DEVICE TO INDEPENDENTLY CONTROL THE GENERAL | | | LIGHTING WITHIN THE SPACE. EACH MANUAL DEVICE SHALL BE | | | READILY ACCESSIBLE AND LOCATED SO THE OCCUPANTS CAN SEE | | | THE CONTROLLED LIGHTING. A. A CONTROL DEVICE SHALL BE | | | INSTALLED THAT AUTOMATICALLY TURNS LIGHTING OFF WITHIN | | | 30 MINUTES OF ALL OCCUPANTS LEAVING A SPACE, EXCEPT | | | SPACES WITH MULTI-SCENE CONTROL, IN THE FOLLOWING: | | | 1. CLASSROOMS (NOT INCLUDING SHOP CLASSROOMS, | | | LABORATORY CLASSROOMS, AND PRESCHOOL THROUGH 12TH GRADE | | | CLASSROOMS) | | | 2. CONFERENCE/MEETING ROOMS. | | | 3. EMPLOYEE LUNCH AND BREAK ROOMS. | | | | | | 3} 13-415.AB.5 INTERIOR LIGHTING POWER, SCOPE. THE | | | INTERIOR LIGHTING POWER ALLOWANCE FOR A BUILDING OR A | | | SEPARATELY METERED OR PERMITTED PORTION OF A BUILDING | | | SHALL BE DETERMINED BY THE SPACE-BY-SPACE METHOD | | | DESCRIBED IN SECTION 13-415.B.1. TRADE-OFFS OF INTERIOR | | | LIGHTING POWER ALLOWANCE AMONG PORTIONS OF THE BUILDING | | | FOR WHICH A DIFFERENT METHOD OF CALCULATION HAS BEEN | | | USED ARE NOT PERMITTED. THE INSTALLED INTERIOR LIGHTING | | | POWER IDENTIFIED IN ACCORDANCE WITH SECTION | | | 13-415.AB.5.1 SHALL NOT EXCEED THE INTERIOR LIGHTING | | | POWER ALLOWANCE DEVELOPED IN ACCORDANCE WITH | | | SECTION13-415.B.1***THIS CAN BE DEMONSTRATED ON THE | | | PLANS INDICATING THE WATTAGES OF THE LUMINAIRES CHOSEN | | | FOR THE PROJECT CONFORM TO THE DENSITY REQUIREMENTS. | | | INDICATE WATTAGES ON THE FIXTURE SCHEDULE TO CORRELATE | | | WITH THE ONES IN THE CALCULATIONS. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2009-11-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-11-18 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-11-18 |
Time |
09:21 |
Sent To |
B |
|
| Notes |
| 2009-11-18 09:22:00 | TO JIM./WRT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2009-11-03 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-11-03 |
Time |
07:44 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-11-03 |
Time |
07:44 |
Sent To |
E |
|
| Notes |
| 2009-11-03 07:44:55 | TO BT./WRT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2009-10-13 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-10-13 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-10-13 |
Time |
17:21 |
Sent To |
|
|
| Notes |
| 2009-10-13 17:21:29 | ********************EXPEDITED********************* | | | GAVE TO DEWEY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2009-09-17 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-09-17 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-09-17 |
Time |
14:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2009-09-09 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-08-14 |
Time |
13:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2009-10-07 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-10-07 |
Time |
13:21 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-10-07 |
Time |
13:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2009-09-09 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-09-09 |
Time |
09:04 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-09-09 |
Time |
08:09 |
Sent To |
|
|
| Notes |
| 2009-09-09 09:04:31 | OK FOR "MECH PER MASTER" PERMIT |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2009-09-01 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2009-09-01 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2009-09-01 |
Time |
15:55 |
Sent To |
|
|
| Notes |
|
|