Plan Review Details - Permit 09080287
Plan Review Stops For Permit 09080287
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-08-20 Cont ID  
Sent By shill Date 2009-08-20 Time 07:39 Rev Time 0.00
Received By shill Date 2009-08-20 Time 07:39 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2009-08-18 Cont ID  
Sent By shill Date 2009-08-18 Time 13:21 Rev Time 0.00
Received By shill Date 2009-08-18 Time 13:21 Sent To  
Notes
2009-08-18 13:24:46****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007 WITH 2009 SUPPLEMENTS
 FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 FROM PREVIOUS LIST:
  
 1. INDICATE WHICH APPROVED ASSEMBLY YOU PROPOSE TO
 INSTALL.
  
 2ND REVIEW, TWO DIFFERENT ASSEMBLIES SELECTED, PAGE6
 FOR INSULATED DECK AND PAGE 16 FOR NON INSULATED DECK.
 PLEASE SELECT ONE ASSEMBLY.
  
 2. SPECIFY ENHANCED FASTENING IN ACCORDANCE WITH
 RAS117, SEE ITEM 7, PAGE 18 (MODIFIED NOA).
  
 NOT ADDRESSED. THE ASSEMBLIES SELECTED HAVE A DESIGN
 PRESSURE LIMITATION OF -60PSF AND -52.5 PSF. CORNER
 ZONES MUST MEET MINIMUM -107.69 (EXPOSURE C). PLEASE
 SELECT ONE ASSEMBLY AND SPECIFY ENHANCED FASTENING FOR
 ZONES 2 AND 3.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-08-12 Cont ID  
Sent By shill Date 2009-08-12 Time 16:04 Rev Time 0.00
Received By shill Date 2009-08-12 Time 16:04 Sent To  
Notes
2009-08-12 16:06:12****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007 WITH 2009 SUPPLEMENTS
 FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1. INDICATE WHICH APPROVED ASSEMBLY YOU PROPOSE TO
 INSTALL.
  
 2. SPECIFY ENHANCED FASTENING IN ACCORDANCE WITH
 RAS117, SEE ITEM 7, PAGE 18 (MODIFIED NOA).
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-08-12 Cont ID  
Sent By shill Date 2009-08-12 Time 16:06 Rev Time 0.00
Received By shill Date 2009-08-20 Time 07:39 Sent To  
Notes
***NONE***