Plan Review Details - Permit 09080269
Plan Review Stops For Permit 09080269
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-10-28 Cont ID  
Sent By jwitmer Date 2009-10-28 Time 14:15 Rev Time 0.55
Received By jwitmer Date 2009-10-28 Time 14:15 Sent To  
Notes
2009-10-28 14:17:24REVISION # 2 10-26-09
  
 A1, A2 & A3

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-09-29 Cont ID  
Sent By jwitmer Date 2009-09-29 Time 13:38 Rev Time 0.00
Received By jwitmer Date 2009-09-29 Time 13:38 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2009-08-24 Cont ID  
Sent By jwitmer Date 2009-08-24 Time 08:35 Rev Time 0.50
Received By jwitmer Date 2009-08-24 Time 08:05 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2009-11-18 Cont ID  
Sent By dpalmer Date 2009-11-18 Time 13:09 Rev Time 0.00
Received By dpalmer Date 2009-11-18 Time 13:09 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2009-08-31 Cont ID  
Sent By dpalmer Date 2009-08-31 Time 16:42 Rev Time 0.00
Received By dpalmer Date 2009-08-31 Time 16:42 Sent To PC
Notes
2009-08-31 16:44:57REDLINED PLANS.
 CODE SECTION NOTED FOR LOAD CALCULATIONS IS FROM UNDER
 THE 2002 NEC.

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2009-11-10 Cont ID  
Sent By mawillia Date 2009-11-10 Time 09:20 Rev Time 0.00
Received By mawillia Date 2009-11-10 Time 09:09 Sent To  
Notes
2009-11-10 09:18:24*****REVISION, DATED 10/26/09, APPROVED*****
  
  
 REVISED PLAN SHEET A2 STAMPED, INITIALED, AND DATED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2009-10-08 Cont ID  
Sent By mawillia Date 2009-10-08 Time 13:27 Rev Time 0.00
Received By mawillia Date 2009-10-08 Time 13:20 Sent To E
Notes
2009-10-08 13:24:44*****RESTAMP*****
  
  
 PLAN SHEET A2 (PREVIOULSY FIRE-STAMPED ON 8/24/2009)
 STAMPED, INITIALED, AND DATED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2009-08-24 Cont ID  
Sent By mawillia Date 2009-08-24 Time 09:48 Rev Time 0.00
Received By mawillia Date 2009-08-24 Time 09:44 Sent To  
Notes
2009-08-24 09:45:35*****APPROVED*****
  
  
 PLAN SHEET A2 STAMPED, INITIALED, AND DATED.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2009-10-28 Cont ID  
Sent By jwitmer Date 2009-10-28 Time 14:17 Rev Time 0.00
Received By jwitmer Date 2009-10-28 Time 14:17 Sent To  
Notes
2009-10-28 14:20:25INCOMING TO C-2

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-09-15 Cont ID  
Sent By kstevens Date 2009-09-15 Time 11:29 Rev Time 0.00
Received By kstevens Date 2009-09-15 Time 11:29 Sent To  
Notes
2009-09-15 11:33:16SENT TO C-31.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-08-31 Cont ID  
Sent By dpalmer Date 2009-08-31 Time 16:42 Rev Time  
Received By dpalmer Date   Time   Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2009-08-31 Cont ID  
Sent By dpalmer Date 2009-08-31 Time 16:42 Rev Time  
Received By dpalmer Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2009-08-31 Cont ID  
Sent By dpalmer Date 2009-08-31 Time 16:42 Rev Time  
Received By dpalmer Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2009-11-04 Cont ID  
Sent By kstevens Date 2009-11-04 Time 10:45 Rev Time 0.00
Received By kstevens Date 2009-11-04 Time 10:45 Sent To  
Notes
2009-11-04 10:46:03REVISION OK -- SHT A4 PLUMBING FLOOR PLAN AND SANITARY
 ISOMETRIC RISER DIAGRAM. REVISION #2.

Review Stop P PLUMBING
Rev No 2 Status P Date 2009-09-21 Cont ID  
Sent By kstevens Date 2009-09-21 Time 10:43 Rev Time 0.00
Received By kstevens Date 2009-09-21 Time 10:43 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2009-08-14 Cont ID  
Sent By kstevens Date 2009-08-14 Time 16:09 Rev Time 0.00
Received By kstevens Date 2009-08-14 Time 16:09 Sent To  
Notes
2009-08-14 16:31:41DENIED
 REFERENCE:
 FBC-2007 PLUMBING
 FBC-2007 CHAPTER 1
  
 1. SHT A-2 GREASE RISER DIAGRAM DOES NOT REFLECT THE
 FLOOR PLAN. THE FLOOR PLAN SHOWS 2 NEW FLOOR SINKS, 1
 NEW FLOOR DRAIN AND ONE NEW SINK, BUT THE RISER DIAGRAM
 ONLY SHOWS THE FLOOR DRAIN. (SHT A3 SHOWS 3 FLOOR
 SINKS) PLEASE CORRELATE. PLEASE SHOW ALL NEW PIPING
 FROM THE CONNECTION TO THE EXISTING PIPING. SHOW ALL
 PIPE SIZES, TRAPS & VENTS. SECTIONS 106.3.5.1.3 &
 701.1.
  
 2. SUBMIT A WATER RISER DIAGRAM FOR ALL NEW WORK. SHOW
 ALL PIPE SIZES, VALVES & (WHERE REQUIRED) WATER HAMMER
 ARRESTORS. SECTIONS 106.3.5.1.3 & 601.1.
  
 3. FLOOR DRAINS ARE NOT APPROVED INDIRECT WASTE
 RECEPTORS. A FLOOR SINK OR HUB DRAIN IS REQUIRED PER
 SECTIONS 802.3 & 802.3.2.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  
  
  

Review Stop Z ZONING
Rev No 1 Status P Date 2009-08-20 Cont ID  
Sent By lfranco Date 2009-08-20 Time 10:53 Rev Time 0.00
Received By lfranco Date 2009-08-20 Time 10:53 Sent To B
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy