| 2009-08-13 16:57:09 | RESIDENTIAL ELECTRICAL PLAN REVIEW |
| | PERMIT: 09080250 |
| | ADD: 810 30TH ST |
| | CONT: JMA ELECTRIC/ 09080258 |
| | TEL: (561)GLADES ROOFING CGC 954-593-5917 |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | 2005 NEC |
| | |
| | NOTE THE PERMIT APPLICATION INDICATES THAT THE |
| | ELECTRICAL UPGRADE TO "CODE" |
| | |
| | 1A) PLANS FAIL TO IDENTIFY THE CODE CYCLE THAT THE |
| | PLANS ARE TO BE DESIGNED TO: |
| | 2007 FBC/ 2009 SUPPLEMENTS |
| | 2007 EXISTING BUILDING CODE/ 2009 SUPPLEMENTS |
| | 2005 NEC |
| | |
| | 1B) EXISTING BUILDING CODE: 401.4 A DESIGN PROFESSIONAL |
| | OR AN OWNER MUST ELECT ONE OR A COMBINATION OF LEVELS |
| | OF ALTERATION PURSUANT TO SECTIONS 403, 404 AND 405 OF |
| | THIS CODE. |
| | |
| | 2) PLEASE REVIEW THE ELECTRICAL PLANS VERSES THE |
| | MECHANICAL PLAN, THE UTILITY ROOM APPLIANCES AND A/C |
| | EQUIPMENT ARE LOCATED IN DIFFERENT LOCATION, PLEASE |
| | CORRELATE PLANS TO THE SAME LOCATION FOR ALL TRADES. |
| | 106.1.2. |
| | |
| | 3) SHEET 1 ALSO NEEDS TO CORRELATE THE PANEL SCHEDULE |
| | AND FLOOR PLAN TO REFLECT THE SAME CIRCUITRY IN THE |
| | PANEL SCHEDULEAS FLOOR PLAN. EXAMPLES ARE THE FLOOR |
| | PLAN INDICATES THE A/C CONDENSORS ON CIRCUIT 24-26WHERE |
| | AS THE PANEL SCHEDULE INDICATE 24-25. A/C HANDLER ON |
| | THE FLOOR PLAN ON CIRCUITS 2&4 IN PANEL SCHEDULE 2 IS |
| | GENERAL LIGHTING AND 4 IS RECEPTACLES. |
| | THERE ARE MORE THAN THESE DISCREPANCIES PLEASE REVIEW |
| | AND CORRECT. CONSTRUCTION DOCUMENTS SHALL BE SUFFICIENT |
| | CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF |
| | THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL |
| | CONFORM TO THE PROVISIONS OF THIS CODE AND RELEVANT |
| | LAWS, ORDINANCES, RULES AND REGULATIONS, AS DETERMINED |
| | BY THE BUILDING OFFICIAL. |
| | 106.1.1. |
| | |
| | 4) THE AIR COMPRESSORS ELECTRICAL SYSMBOL IS ACTUALLY |
| | DRAWN IN AS A 240 OULET NOT AS A REQUIRED DISCONNECT |
| | PLEASE CORRECT. |
| | 440.11 GENERAL. THE PROVISIONS OF PART II ARE INTENDED |
| | TO REQUIRE DISCONNECTING MEANS CAPABLE OF DISCONNECTING |
| | AIRCONDITIONING AND REFRIGERATING EQUIPMENT, INCLUDING |
| | MOTORCOMPRESSORS AND CONTROLLERS FROM THE CIRCUIT |
| | CONDUCTORS. PLEASE INDICATE A TRUE DISCONNECT. |
| | |
| | 5) FLOOR PLAN INDICATES (2) SUB-PANELS LABELED "B" |
| | WHERE AS THE RISER DIAGRAM ONLY INDICATES A SINGLE |
| | PANEL, AGAIN PLEASE IDENTIFY WHICH PANEL IS WHERE, |
| | PANEL A AND PANEL B. |
| | |
| | 6) THE OTHER ISSUE IS THE NEW 200 AMP DISCONNECT |
| | BREAKER, IS MISSING THE A/C RATING. 110.9 INTERRUPTING |
| | RATING. EQUIPMENT INTENDED TO INTERRUPT CURRENT AT |
| | FAULT LEVELS SHALL HAVE AN INTERRUPTING RATING |
| | SUFFICIENT FOR THE NOMINAL CIRCUIT VOLTAGE AND THE |
| | CURRENT THAT IS AVAILABLE AT THE LINE TERMINALS OF THE |
| | EQUIPMENT. EQUIPMENT INTENDED TO INTERRUPT CURRENT AT |
| | OTHER THAN |
| | FAULT LEVELS SHALL HAVE AN INTERRUPTING RATING AT |
| | NOMINAL CIRCUIT VOLTAGE SUFFICIENT FOR THE CURRENT THAT |
| | MUST BE INTERRUPTED . |
| | |
| | 7A) FLOOR PLAN ALSO INDICATES THE UTILITY ROOM PANEL |
| | JUST THE WIDTH OF THE PANEL PLEASE REVIEW: 408.4 |
| | CIRCUIT DICTIONARY. ALL CIRCUITS AND CIRCUIT |
| | MODIFICATINS SHALL BE LEGIBLY IDENTIFIED AS TO PURPOSE |
| | OR USE ON A CIRCUIT DIRECTORY LOCATED ON THE FACE OR |
| | INSIDE OF THE PANEL DOOR IN THE CASE OF A PANEL OARD, |
| | AND AT EACH SWITCH ON A SWITCHBOARD. NOTE IDENTIFY |
| | CIRCUITS BY ROOM NOT GENERAL LIGHTING OR RECEPTACLES. |
| | |
| | 7B) PANEL LOCATIONS NEED TO COMPLY WITH: 110.26 (1) |
| | DEPTH OF WORKING SPACE, (2) WIDTH OF WORKING SPACE & |
| | (3) HEIGTH OF WORKING SPACE. FOR BOTH PANEL LOCATIONS. |
| | THE DEDICATED ELECTRICAL SPACE MUST BE CLEAR OF ANY |
| | PIPING, DUCTS, LEAK PROTECTION APPARATUS, OR EQUIPMENT |
| | FOREIGN TO THE ELECTRICAL INSTALLATION. PLUMBING, |
| | HEATING, VENTILATION, AND |
| | AIR-CONDITIONING PIPING, DUCTS, AND EQUIPMENT MUST BE |
| | INSTALLED OUTSIDE THE WIDTH AND DEPTH ZONE. |
| | |
| | 8) NOTE THE PANEL SCHEDULE DOES NOT INCLUDE THE RANGE, |
| | WATER HEATER NOR DRYER SYMBOL INDICATING ELECTRICAL |
| | CONNECTIONS, IT IS UNKNOWN IF THESE APPLIANCES ARE |
| | ELECTRIC OR GAS, IF GAS THE SMOKE ALARMS WILL ALSO NEED |
| | TO BE CARBON MONOXIDE DETECTORS ALSOFL S S 553.885. |
| | |
| | 9) THE BACK REAR BEDROOM DOES INDICATE A SMOKE ALARM |
| | WITHIN THE UNIT BUT NOT ONE OUTSIDE OF THE BEDROOM THIS |
| | ALSO HOLDS TRUE FOR THE MASTER BEDROOM FBC RESIDENTIAL |
| | 313.2(2) AND NFPA 72. |
| | |
| | 10) THE SMOKE ALARMS LOCATED WWITHIN 20' OF COOKING |
| | WILL NEED TO BE COMPLY WITH NFPA 72-11.8.3.5 (4) SMOKE |
| | ALARMS AND SMOKE DETECTORS INSTALLED WITHIN A 6.1 M (20 |
| | FT) HORIZONTAL PATH OF A COOKING APPLIANCE SHALL BE |
| | EQUIPPED WITH AN ALARM-SILENCING MEANS OR BE OF THE |
| | PHOTOELECTRIC TYPE. |
| | |
| | 11) UTILITY ROOM CIRCUIT IS NOT SHOWN ON PLANS |
| | REQUIRING A GFCI CIRCUIT. 210.8(C)(2) LAUNDRY BRANCH |
| | CIRCUIT. |
| | |
| | 12) BEDROOMS MISSING OUTLETS ON PLANS, PLEASE PROVIDE |
| | ARC FAULT OUTLET CIRCUIT PER 210.12(B) DWELLING UNIT |
| | BEDROOMS.210.52OUTLET SPACING. |
| | |
| | 13)LIGHTING NOT SHOWN ON PLANS SWITCH LOCATIONS |
| | 210.70.INTERIOR LOCATIONS |
| | |
| | 14) EXTERIOR EXIT LIGHTS NOT SHOWN NOR SWITCH LOCATIONS |
| | 210.70. |
| | |
| | 15) REQUIRED SERVICE OUTLETS FOR A/C |
| | EQUIPMENT.210.52(E), 210.8(3) OUTDOORS 210.63 . |
| | |
| | 16) THERMOSTATS ARE NOT SHOWN. |
| | |
| | 17) 2ND AIR HANDLIER NOT SHOWN ON PANEL SCHEDULE. |
| | |
| | 18) THE ELECTRIC RISER IS MISSING GROUND ROD LENGTH, |
| | 250.66 & TABLE 250.66. |
| | |
| | 19) LAUNDRY/ WASHER PLEASE REVIEW 210.52, 210.11C2 & |
| | 220.52.3 |
| | |
| | 20) MISSING EQUIPMENT GROUND BETWEEN MAIN AND PANEL |
| | 250.122 |
| | |
| | 21) REQUIRED GFI WITHIN 3 FT OF SINK 210.52(D), |
| | 21011.C.3 210.8A1 |
| | |
| | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A |
| | RESULT OF THE ADDITIONAL INFORMATION REQUESTED |
| | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| | THIS REVIEW. |
| | |
| | STARTING AUGUST 21, 2009, THE CONSTRUCTION SERVICES |
| | DEPARTMENT WILL BE CLOSED ON FRIDAYS UNTIL FURTHER |
| | NOTICE. |
| | |
| | OPENING HOURS MONDAY - THURSDAY WILL REMAIN AT 8:00 AM |
| | - 5:00 PM. |
| | |
| | JIM WITMER C. B. O. |
| | BUILDING PLAN REVIEW II |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)805-6731 |
| | E-MAIL: [email protected] |
| | SURVEY: |
| | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |
| | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF |
| | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 |
| | |
| | |