Plan Review Details - Permit 09070624
| Plan Review Stops For Permit 09070624 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2009-08-04 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-08-04 |
Time |
11:54 |
Rev Time |
1.55 |
| Received By |
jwitmer |
Date |
2009-08-04 |
Time |
09:10 |
Sent To |
E |
|
| Notes |
| 2009-08-04 12:12:33 | FL# 10605-R0 | | | NOA# 07-0803.01 | | | ADVANCED GREEN TECHNOLOGIES, INC | | | ROOF PERMITED WITH BASE BUILDING | | | ATLANTIC & CARIBBEAN ROOF CONSULTING | | | NOA# 08-0221.02 | | | PAGES 20,21 | | | PAGE 21 SURFACING COMMENT# 7 ALLOWS ADVANCED GREEN | | | TECHNOLOGIES PHOTOVOLTAIC LAMINATE ROOF SYSTEMS , | | | | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | SURVEY: | | | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2009-09-15 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-09-15 |
Time |
17:57 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-09-15 |
Time |
17:57 |
Sent To |
PC |
|
| Notes |
| 2009-09-15 17:57:44 | | | | ** PROVISO ** | | | | | | | | | 1) NOTE: FINAL APPROVAL OF INTERCONNECTION DOCUMENTS | | | FROM FLORIDA POWER AND LIGHT TO BE SUBMITTED FOR FILE. | | | | | | 2) NOTE: REDLINED PLANS: THE OPTIONAL METER SHOWN ON | | | RISER WHICH IS NOTED TO BE INSTALLED BY OTHERS SHALL BE | | | UNDER SEPARATE PERMIT IF NOT INSTALLED BY FPL. | | | RISER SHALL BE REVISED BEFORE FINAL IN ORDER TO REFLECT | | | ACCURATELY WHAT WAS INSTALLED EVEN IF INSTALLED BY | | | OTHERS. | | | ONLY WORK DONE AND INSTALLED BY THE UTILITY COMPANY IS | | | EXEMPT FROM PERMITTING. ALL OTHER WORK SHALL OBTAIN | | | PERMIT. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2009-09-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-09-08 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-09-08 |
Time |
11:00 |
Sent To |
PC |
|
| Notes |
| 2009-09-08 11:01:10 | ** DENIED REVIEW ** | | | | | | ** COMMENTS #1 AND #2 FROM PREVIOUS REVIEW ARE STILL IN | | | NEED OF ADDRESSING. | | | | | | 1) NOTE: NO PRODUCT CUT SHEETS/SPECS SUBMITTED. 110.3 | | | | | | 2) NOTE: NO LETTER SUBMITTED FROM FPL THAT INSTALLATION | | | WILL MEET THEIR SERVICE STANDARDS. PLANS NOW STATE THAT | | | A UTILITY BI-DIRECTIONAL METER WILL BE INSTALLED BY | | | OTHERS. | | | THE APPLIED SCOPE OF WORK IS NOT PERMITTED UNTIL | | | SERVICE WORK IS CLEARED UP. | | | THIS IS A 1000AMP SERVICE. | | | | | | 3) NOTE: SHOW LOCATIONS OF DISCONNECTING MEANS MEETING | | | 690.13,14,15, 230.2E | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2009-08-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-08-12 |
Time |
10:52 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-08-12 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2009-08-12 10:55:05 | | | | ** DENIED REVIEW ** | | | | | | 1) NOTE: PLEASE SUBMIT THE MANUFACTURES SPECS/CUT | | | SHEETS FOR THE PROPOSED PHOTOVOLTAIC SYSTEM. PLEASE BE | | | SURE LISTING FROM A NATIONALLY RECOGNIZED TESTING | | | LABORATORY IS SHOWN. ( NRTL) 110.3 | | | | | | 2) NOTE: PLEASE SEE PHOTOVOLTAIC RISER WHICH INDICATES | | | THE SERVICE AS HAVING A *MULTI-DIRECTIONAL METER*. | | | BASED ON THE ORIGINAL RISER AND PLANS THIS IS A 1000AMP | | | SERVICE. HOW DOES THIS SIZE SERVICE HAVE A | | | MULTI-DIRECTIONAL METER? | | | PLEASE OBTAIN LETTER FROM LOCAL POWER COMPANY FLORIDA | | | POWER AND LIGHT ( FPL) FOR THE INSTALLATION MEETING | | | SERVICE STANDARDS. | | | | | | 3) NOTE: PLEASE SEE NOTES ON PLANS MENTIONS COLOR | | | CODING FROM THE 1990 NATIONAL ELECTRICAL CODE. ( | | | SPECIFICALLY) PLEASE BE SURE TO REVISE. | | | THE PLANS ARE UNDER THE 2005 NEC. | | | | | | 4) NOTE: PLEASE INDICATE PROTECTION PER 690.6 (D). | | | | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2009-09-14 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-09-14 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-09-14 |
Time |
16:00 |
Sent To |
|
|
| Notes |
| 2009-09-14 16:01:49 | ***EXPEDITED**** GAVE TO DEWEY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2009-08-27 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-08-27 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-08-27 |
Time |
09:26 |
Sent To |
|
|
| Notes |
| 2009-08-27 09:27:05 | GAVE TO DEWEY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2009-08-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-07-28 |
Time |
13:01 |
Sent To |
|
|
| Notes |
| 2009-07-28 13:01:31 | SENT TO COMMERCIAL BOX # C-11 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2009-08-07 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2009-08-07 |
Time |
19:31 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2009-08-07 |
Time |
19:31 |
Sent To |
|
|
| Notes |
|
|
|