| 2009-08-04 16:55:37 | BUILDING PLAN REVIEW |
| | PERMIT: 09070474 |
| | ADD: 2745 WHITE WING LN. |
| | CONT: R & W PROPERTIES INC. |
| | TEL: (772)577-1991 |
| | FL BLD CODE= 2007 FLORIDA BUILDING CODE |
| | W/ 2009 FBC SUPPLEMENTS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 1ST PLUMBING REVIEW |
| | ACTION: DENIED |
| | |
| | 1) SANITARY RISER ISOMETRIC: |
| | 1A) PLEASE SEE NEW BRANCH FOR NEW BATHROOM, PLANS |
| | INDICATE THE SHOWER COMING DIRECTLY OF THE LAV BRANCH |
| | LINE, THE LAV BRANCH LINE WOULD BE WITHIN A WALL AS |
| | DRAWN AND THE SHOWER DRAIN ABOVE THE FLOOR SLAB. |
| | |
| | 1B) ON THIS SAME BRANCH LINE PLANS INDICATE A SINK |
| | RATHER THAN A LAVATORY WITH NO VENTING? |
| | |
| | 1C) NEITHER THE LAV NOR SHOWER INDICATE THE SIZE OF |
| | PIPE FOR THE DRAINAGE PIPE? P 3005.4.1. |
| | |
| | 1D) THE EXISTING BATHROOM RISER INDICATES A SINK (LAV) |
| | AND WASHING MACHINE BOTH DUMPING INTO A VERTICAL |
| | FITTING. PLEASE REVIEWP3005.1. |
| | P3005.1.1 HORIZONTAL TO VERTICAL (MULTIPLE CONNECTION |
| | FITTINGS). DOUBLE FITTINGS SUCH AS DOUBLE SANITARY TEES |
| | AND TEE-WYES OR APPROVED MULTIPLE CONNECTION FITTINGS |
| | AND BACK-TO-BACK FIXTURE ARRANGEMENTS THAT CONNECT TWO |
| | OR MORE BRANCHES AT THE SAME LEVEL SHALL BE PERMITTED |
| | AS LONG AS DIRECTLY OPPOSING CONNECTIONS ARE THE SAME |
| | SIZE AND THE DISCHARGE INTO DIRECTLY OPPOSING |
| | CONNECTIONS IS FROM SIMILAR FIXTURE TYPES OR FIXTURE |
| | GROUPS. DOUBLE SANITARY TEE PATTERNS SHALL NOT RECEIVE |
| | THE DISCHARGE OF BACK-TO-BACK WATER CLOSETS AND |
| | FIXTURES OR APPLIANCES WITH PUMPING ACTION DISCHARGE. |
| | |
| | 1E) ALSO NOTE THAT THE PLAN INDICATES THE WASHING |
| | MACHINE BRANCH LINE IS HORIZONTAL, THE DRAIN PIPE |
| | SHOULD BE VERTICAL TO ALLOW THE WATER TO DISCHARGE |
| | SINCE THIS IS A PUMPING ACTION DISCHARGE. THIS DRAIN |
| | SHOULD TIE INTO THE HORIZONTAL DRAIN.P2706.2.1 LAUNDRY |
| | TRAY CONNECTION. A LAUNDRY TRAY WASTE LINE IS PERMITTED |
| | TO CONNECT INTO A STANDPIPE FOR THE AUTOMATIC CLOTHES |
| | WASHER DRAIN. THE STANDPIPES SHALL NOT BE LESS THAN 30 |
| | INCHES (762 MM) AS MEASURED FROM THE CROWN WEIR. THE |
| | OUTLET OF THE LAUNDRY TRAY SHALL BE A MAXIMUM |
| | HORIZONTAL DISTANCE OF 30 INCHES (762 MM) FROM THE |
| | STANDPIPE TRAP. |
| | |
| | |
| | 1F) TO THE RIGHT END OF THE WASTE OR DRAIN PIPE THE |
| | PLANS INDICATE A 3" PIPE BUT AS THE FLOW LEADS TO THE |
| | LEFT PLANS INDICATE A 2" DRAIN PIPE. P3005.1.7 CHANGE |
| | IN SIZE. THE SIZE OF THE DRAINAGE PIPING SHALL NOT BE |
| | REDUCED IN SIZE IN THE DIRECTION OF THE FLOW. A 4-INCH |
| | BY 3-INCH (102 MM BY 76 MM) WATER CLOSET CONNECTION |
| | SHALL NOT BE CONSIDERED AS A REDUCTION IN SIZE. |
| | |
| | JIM WITMER C. B. O. |
| | BUILDING PLAN REVIEW II |
| | 1 & 2 FAMILY PLAN REVIEW SFP-100 |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)805-6731 |
| | E-MAIL: [email protected] |
| | SURVEY: |
| | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
| | |