Plan Review Details - Permit 09070459
Plan Review Stops For Permit 09070459
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-08-26 Cont ID  
Sent By jwitmer Date 2009-08-26 Time 11:04 Rev Time 0.00
Received By jwitmer Date 2009-08-26 Time 10:04 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-08-11 Cont ID  
Sent By jwitmer Date 2009-08-11 Time 13:57 Rev Time 1.00
Received By jwitmer Date 2009-07-23 Time 13:59 Sent To  
Notes
2009-07-23 16:29:39BUILDING PLAN REVIEW
 PERMIT: 09070459
 ADD: 101 S FLAGLER DR
 CONT: WESCO FOUNTAINS/ CPC1457881
 TEL: (941)809-8819
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) IN ALL CASES OF THE SEVEN WATER FEQATURES ATTAHED TO
 SHEET WF-S1 IS A 8X11 FROM ONM&J WITH CODE INFORMATION,
 WIND AND DESIGN LOADSAND DESIGN FOR REBAR AND CONCRETE.
 THESE ARE GENERIC IN NATURE NOT INDICATING FOR WHAT
 TYPE OF STRUCTURE OR LOCATION AND THE DOCUMENT IS
 NEITHER SIGNED NOR RAISED SEAL.
  
 61G15-23.002(2) FL. ADMIN. CODE. PLANS SIGNED & SEALED
 BY A PROFESSIONAL ENGINEER SHALL INCLUDE EITHER THE:
 NAME, ADDRESS AND LICENSE NUMBER OF THE ENGINEER OR,
 THE NAME AND LICENSE NUMBER OF THE ENGINEER AND THE
 NAME, ADDRESS AND CERTIFICATE OF AUTHORIZATION NUMBER
 OF THE ENGINEERING BUSINESS THROUGH WHICH THE ENGINEER
 IS PRACTICING (471.025 F.S. AND 471.023 F.S.).
  
 2) THE PERMIT APPLICATION INDICATES ALSO THERE TO BE
 INSTALLED 3 UL APPROVED VAULTS, PLEASE PROVIDE
 DOCUMENTS FOR THESE VAULTS. THE SITE PLAN INDICATES THE
 LOCATION BUT NOT AT WHAT DEPTH THEY WILL BE INSTALLED.
 THIS AREA IS IN A FLOOD ZONE AND MUST MEET THE
 FOLLOWING CRITERIA:
  
 CITY CODE OF ORDINANCES SEC 94-546(B)(2)NONRESIDENTIAL
 CONSTRUCTION. ALL NEW CONSTRUCTION OR SUBSTANTIAL
 IMPROVEMENT OF ANY COMMERCIAL, INDUSTRIAL OR OTHER
 NONRESIDENTIAL STRUCTURE SHALL EITHER HAVE THE LOWEST
 FLOOR, INCLUDING BASEMENT, ELEVATED TO THE LEVEL OF SIX
 INCHES ABOVE THE BASE FLOOD ELEVATION OR, TOGETHER WITH
 ATTENDANT UTILITY AND SANITARY FACILITIES, BE
 FLOODPROOFED SO THAT BELOW SIX INCHES ABOVE THE FLOOD
 BASE LEVEL THE STRUCTURE IS WATERTIGHT, WITH WALLS
 SUBSTANTIALLY IMPERMEABLE TO THE PASSAGE OF WATER AND
 WITH STRUCTURAL COMPONENTS HAVING THE CAPABILITY OF
 RESISTING HYDROSTATIC AND HYDRODYNAMIC LOADS AND
 EFFECTS OF BUOYANCY. A REGISTERED PROFESSIONAL ENGINEER
 OR ARCHITECT SHALL CERTIFY THAT THE STANDARDS OF THIS
 SUBSECTION ARE SATISFIED. SUCH CERTIFICATION SHALL BE
 PROVIDED TO THE CITY ENGINEER.
  
 3) IN ALL SEVENWATER FEATURES THE PLANS INDICATE USE OF
 STRUCTURAL FOAM PLEASE PROVIDE INFORMATION FOR THE USE
 OF STRUCTURAL FOAM IN THIS TYPE APPLICATION. 106.1.2
 ADDITIONAL INFORMATION REQUIRED.
 INFORMATIONAL 106.1.1* W.P.B. ADMINISTRATIVE CODE/2004
 DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN
 THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF
 MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY
 WITH THE TECHNICAL CODES. CONSTRUCTION DOCUMENTS SHALL
 BE SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT
 IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
  
 INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY PAGES AS NECESSARY.
 A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
 SURVEY:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2009-09-01 Cont ID  
Sent By btrobaug Date 2009-08-24 Time 09:35 Rev Time 0.00
Received By btrobaug Date 2009-08-20 Time 07:26 Sent To  
Notes
2009-08-24 09:33:04 
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2007 FLORIDA BUILDING CODE, 2009 REVISIONS, 2005
 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND
 NONCOMPLIANT WITH THE FOLLOWING:
  
 1} THE PLAN SUBMITTED IS INCOMPLETE AND HAS A NOTATION
 INDICATING SUGGESTED LOCATIONS AND RECOMMENDATIONS.
 SUBMIT PLANS INDICATING THE SCOPE OF WORK UNDER THIS
 PERMIT APPLICATION.PANEL DESIGNATIONS , LOCATIONS AND
 BRANCH CIRCUIT NUMBERS ARE ALSO REQUIRED.
  
 2} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST
 PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.3. FBC.
 IF AN ARCHITECT OR ENGINEER, COMPLY WITH 481 AND 471
 FS, RESPECTIVELY.
 THE CONTRACTOR OF RECORD MAY BE THE DESIGN PROFESSIONAL
 IF EXEMPTIONS UNDER CHAPTER 471.003, FLORIDA STATUTES,
 IF EXEMPTIONS APPLY.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 561/805-6718
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2009-08-24 Cont ID  
Sent By mcarsill Date 2009-08-24 Time 12:42 Rev Time 0.00
Received By mcarsill Date 2009-08-24 Time 12:37 Sent To  
Notes
2009-08-24 12:42:24WEST PALM BEACH WATERFRONT COMMONS, WATER FEATURES
 WATER ELEMENTS 1,2,3,4,5,6, AND 7
 PERMIT # 09070459
  
 1. ALL ELECTRICAL INSTALLATION TO COMPLY WITH NFPA 70,
 THE NATIONAL ELECTRIC CODE.
  
 2. ALL ELECTRICAL EQUIPMENT IS TO BE PROPERLY INSTALLED
 AND REQUIRED EQUIPMENT SHALL BE PROPERLY GROUNDED.
  
 3. SIGNS SHOULD BE POSTED INDICATING NO SWIMMING AND
 CHILDREN SHALL BE SUPERVISED.
  
 4. ARE THE VAULTS SUBJECT TO ANY ENTRY BY PERSONS
 RESPONSIBLE FOR MAINTENANCE.
  
 APPROVED PROVISO
  
  
 MIKE CARSILLO, BATTALION CHIEF
 BUREAU OF FIRE PREVENTION
 804-4709 PHONE
 804-4774 FAX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-09-02 Cont ID  
Sent By btrobaug Date 2009-09-02 Time 09:04 Rev Time 0.00
Received By btrobaug Date 2009-07-22 Time 16:08 Sent To PC
Notes
2009-07-22 16:09:28B-16

Review Stop P PLUMBING
Rev No 1 Status P Date 2009-08-14 Cont ID  
Sent By kstevens Date 2009-08-14 Time 10:59 Rev Time 0.00
Received By kstevens Date 2009-08-14 Time 10:59 Sent To  
Notes
2009-08-14 09:19:10 
  
 WATER FEATURES ARE NOT FOR PUBLIC USE PER APPLICATION.
  
  
  
 .