| Plan Review Stops For Permit 09070203 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
N |
Date |
2010-03-23 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2010-03-23 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2010-03-23 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2010-03-23 11:31:25 | MET WITH DON KULA. HE SAID THEY INSTALLED WINDOWS WITH | | | NOA 05-0516.03. THIS WINDOW WAS APPROVED ON 11/04/09 | | | AND MEETS THE DESIGN PRESSURES CALCULATED BY THE | | | ARCHITECT. NO REVISION REQUIRED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2009-11-12 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-11-12 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-11-12 |
Time |
13:03 |
Sent To |
PC |
|
| Notes |
| 2009-11-12 13:04:50 | ONE SET OF PLANS SUBMITTED FOR RE-STAMPING. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2009-11-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-11-04 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-11-04 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2009-11-04 14:10:58 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | | | 1- REVISE LEGAL DESCRIPTION AND SITE DATA ON SHEET A-1. | | | PROVIDE CORRECT INFORMATION. | | | | | | 2- PROVIDE PRODUCT APPROVALS FOR SINGLE HUNG WINDOWS | | | THAT MEET THE DESIGN PRESSURES CALCULATED BY THE | | | ARCHITECT. | | | | | | 3- PROVIDE PRODUCT APPROVAL FOR WINDOW MULLIONS. | | | | | | 4- STORM SHUTTERS: | | | A) PROVIDE PRODUCT APPROVALS THAT MEET THE DESIGN | | | PRESSURES CALCULATED BY THE ARCHITECT. | | | B) PROVIDE COMPLETE INSTALLATION SCHEDULE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2009-09-21 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-09-21 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-09-17 |
Time |
11:04 |
Sent To |
|
|
| Notes |
| 2009-09-21 10:02:39 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | | | 1- REVISE LEGAL DESCRIPTION AND SITE DATA ON SHEET A-1. | | | PROVIDE CORRECT INFORMATION. | | | | | | 2- PROVIDE PRODUCT APPROVALS FOR SINGLE HUNG WINDOWS | | | THAT MEET THE DESIGN PRESSURES CALCULATED BY THE | | | ARCHITECT. | | | | | | 3- PROVIDE PRODUCT APPROVAL FOR WINDOW MULLIONS. | | | | | | 4- STORM SHUTTERS: | | | A) PROVIDE PRODUCT APPROVALS THAT MEET THE DESIGN | | | PRESSURES CALCULATED BY THE ARCHITECT. | | | B) PROVIDE COMPLETE INSTALLATION SCHEDULE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2009-07-31 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-07-31 |
Time |
12:41 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-07-31 |
Time |
12:41 |
Sent To |
|
|
| Notes |
| 2009-07-31 12:52:51 | NEW SF RESIDENCE (R3), BUILDING REVIEW CHECKLIST. | | | 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | | | 1- NEED RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13 | | | FLORIDA STATUTE. | | | NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK UP. | | | | | | 2- BRING PLANS TO PALM BEACH COUNTY FOR IMPACT FEES. | | | BRING BACK STAMPED PLANS AND COPY OF PAID RECEIPT. | | | | | | 3- SHEET A-1: PROVIDE DRAINAGE PLAN. SEC. R401.3 OF | | | 2007 FLORIDA RESIDENTIAL CODE. SHOW ON SITE PLAN | | | DRAINAGE OF WATER BY USING ARROWS SHOWING DIRECTION OF | | | WATER. WATER CAN'T BE DIVERTED TO THE NEIGHBOR'S | | | PROPERTY. | | | | | | 4- SHEET A-2: | | | A) ACCORDING TO SEC. R301.2.1.4.3 OF 2009 REVISIONS TO | | | THE 2007 FLORIDA RESIDENTIAL CODE THIS BUILDING IS | | | LOCATED ON EXPOSURE "C" NOT "B". REVISE DESIGN DATA | | | NOTE #7 AND WIND DESIGN INFORMATION. ALSO, REVISE ALL | | | DESIGN PRESSURES FOR COMPONENTS AND CLADDING. | | | | | | B) PROVIDE AREA TABULATIONS. EX: A/C AREA, STORAGE, | | | PORCH TO PROPERLY ASSESS RADON AND BUILDING VALUATION | | | SEC. 108.3 CITY AMENDMENTS TO FBC. | | | | | | 5- SHEET A-3: | | | A) PROVIDE DOOR AND WINDOW SCHEDULE OR SPECIFY SIZE OF | | | DOORS/WINDOWS ON FLOOR PLAN TO VERIFY COMPLIANCE WITH | | | THE EGRESS REQUIREMENTS OF SEC. R310 AND R311. AND TO | | | VERIFY COMPLIANCE WITH BATHROOM DOOR MIN. SIZE. | | | | | | B) REVISE DOORS AND WINDOWS DESIGN PRESSURES. | | | COORDINATE WITH ITEM #4 ABOVE. | | | | | | 6- SHEET A-4: | | | A) REVISE ROOF SHEATHING NOTES SHOWN ON THE WALL | | | SECTIONS. NEED TO USE MIN. 8D RING SHANK NAILS AND THEY | | | NEED TO BE MIN. 4"O.C. ON ROOF ZONE 3. AS REQUIRED BY | | | SEC. R803.2.3.1 AND FIGURE R803.2.3.1 OF 2007 FLORIDA | | | RESIDENTIAL CODE. | | | | | | B) FRONT ELEVATION DOESN'T MATCH FLOOR PLAN. | | | | | | C) COORDINATE SPECIFICATIONS SHOWN ON WALL SECTIONS FOR | | | WALL TO ROOF TRUSS ATTACHMENT TO MATCH ROOF FRAMING | | | PLAN SPECIFICATIONS. | | | | | | D) PROVIDE COMPLETE SPECIFICATIONS ON WALL SECTIONS FOR | | | ATTIC VENTILATION TO SHOW COMPLIANCE WITH SEC. R806. | | | SPECIFY SIZE AND LOCATION OF VENTS. | | | | | | E) REVISE INSULATION VALUE SHOWN ON WALL SECTION TO | | | MATCH ENERGY CALCULATIONS. ALSO, R19 DOESN'T FIT ON 2X4 | | | WALL. REVISE AS REQUIRED. | | | | | | F) SEC. 8/A-4: SPECIFY STUCCO THICKNESS AS REQUIRED BY | | | SE TABLE R702.1(1) OF 2007 FLORIDA RESIDENTIAL CODE. | | | ALSO, REQUIRES 2 LAYERS OF VAPOR BARRIER AS REQUIRED BY | | | SEC. R703.6.3. | | | | | | G) SECTION 7/A-4: PROVIDE DETAIL/SPECIFICATIONS FOR | | | PREPARATION OF OPENINGS TO RECEIVE STORM SHUTTERS. | | | | | | H) SEC. 9/A-4: SPECIFY LOCATION OF VENTS. SEC. R806 | | | 2007 FLORIDA RESIDENTIAL CODE. | | | | | | 7- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE | | | 9B-72 FOR: | | | A) WINDOW MULLIONS AS SHOWN ON PLANS. AND, CLEARLY MARK | | | SPECIFIC MULLION SIZE TO VERIFY COMPLIANCE WITH THE | | | CALCULATED DESIGN PRESSURES. | | | | | | B) SINGLE HUNG WINDOWS: NEED TO PROVIDE CURRENT FLORIDA | | | PRODUCT APPROVAL FL4065-R5 AND CORRESPONDING DRAWINGS. | | | PRODUCT APPROVAL SUBMITTED FL4065.1 R3 IS NOT THE MOST | | | CURRENT ONE. | | | | | | 8- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC. | | | | | | 9- ENERGY CALCULATIONS SUBMITTED. | | | A) COMPLETE ALL THE INFORMATION ON TOP OF FORM | | | INCLUDING THE SPECIFIC ADDRESS WHEN APPLYING FOR | | | PERMIT. | | | | | | B) OWNER/AGENT TO SIGN AND DATE BOTTOM OF FORM TO | | | CERTIFY COMPLIANCE WITH THE CODE. | | | | | | C) COMPLETE ALL THE INFORMATION ON THE CODE COMPLIANCE | | | CHECKLIST PAGE. NOTHING WAS CHECKED. | | | | | | 10- STORM SHUTTERS: PROVIDE COMPLETE INSTALLATION | | | SCHEDULE. SEE ATTACHED SAMPLE. AND, CLEARLY MARK ON | | | SHUTTERS DRAWINGS SPECIFIC MOUNTING CONDITIONS (EX; | | | WALL MOUNTED, BUILT OUT, ETC) AND SPECIFIC ANCHOR TYPE | | | AND SPACING TO BE USED TO VERIFY COMPLIANCE WITH THE | | | CALCULATED DESIGN PRESSURES OF SEC. R301 OF 2007 | | | FLORIDA RESIDENTIAL CODE. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2009-12-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-12-22 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-12-22 |
Time |
16:03 |
Sent To |
|
|
| Notes |
| 2009-12-22 16:05:34 | *DENIED ** | | | | | | 1) NOTE: ORIGINAL PROVISO FROM 10/2 HAS STILL NOT BEEN | | | ADDRESSED. PLANS SUBMITTED TWICE WITHOUT CORRECTIONS | | | MADE TO ELECTRICAL. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2009-10-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-10-26 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-10-26 |
Time |
14:16 |
Sent To |
|
|
| Notes |
| 2009-10-26 14:16:54 | SAME PROVISO AS PREVIOUS NOTES. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2009-10-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-10-02 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-10-02 |
Time |
12:02 |
Sent To |
|
|
| Notes |
| 2009-10-02 12:04:13 | ** PROVISO ** | | | | | | 1) NOTE: THE PLANS STATE A 2006 EDITION OF NFPA-70 ( | | | NEC). | | | THE PROJECT IS SUBMITTED UNDER THE 2005 NEC. THE NEXT | | | CODE IN EFFECT WILL BE THE 2008 NEC. | | | | | | 2) NOTE: FOOTER STEEL IS MISSING FROM GROUNDING | | | ELECTRODE SYSTEM. 250.50 PLANS STATE THAT CONCRETE IS | | | FIBER REINFORCED HOWEVER BASED ON STRUCTURAL PLANS | | | THERE ARE 3-#5 BARS IN FOOTERS. | | | | | | 3) NOTE: STORAGE TYPE WATER HEATERS ARE CONTINUOUS LOAD | | | WHICH REQUIRES LOAD TO BE FIGURED AT 125%. | | | | | | 4) NOTE: PLANS STILL INDICATE SMOKE DETECTORS INSTEAD | | | OF SMOKE ALARMS. PLEASE SEE NFPA-72 11.5.1, 11.8.3 | | | | | | 5) NOTE: PLANS/TITLE BLOCKS DO NOT CONTAIN ANY ADDRESS | | | ON TITLE BLOCKS. FAC 61G1-16.004. FBC 106.5 FOR RECORD | | | PLANS. THIS WAS REDLINED ON ELECTRICAL SHEETS. | | | | | | 6) NOTE: WASHER LOAD SHALL BE 1.5/1500VA MINIMUM PER | | | 220.52 | | | | | | ** PLEASE REVISE PLANS BEFORE ROUGH ALONG WITH ANY | | | OTHER REVISIONS. | | | | | | **IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2009-07-28 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-07-28 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-07-28 |
Time |
16:01 |
Sent To |
|
|
| Notes |
| 2009-07-28 16:30:55 | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2007 FLORIDA RESIDENTIAL BUILDING CODE, 2009 | | | REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND | | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} RECEPTACLE SPACING MUST COMPLY WITH 210.52(A)(1) AND | | | 210.52(A)(2). 2005 NEC. SEE REVIEWED PLAN FOR | | | DEFICIENCIES.***BEDROOM #1. | | | | | | 2} 250.50 GROUNDING ELECTRODE SYSTEM | | | ALL GROUNDING ELECTRODES AS DESCRIBED IN 250.52(A)(1) | | | THROUGH (A)(6) THAT ARE PRESENT AT EACH BUILDING OR | | | STRUCTURE SERVED SHALL BE BONDED TOGETHER TO FORM THE | | | GROUNDING ELECTRODE SYSTEM. WHERE NONE OF THESE | | | GROUNDING ELECTRODES EXIST, ONE OR MORE OF THE | | | GROUNDING ELECTRODES SPECIFIED IN 250.52(A)(4) THROUGH | | | (A)(7) SHALL BE INSTALLED AND USED.250.52(A)(3) | | | CONCRETE-ENCASED ELECTRODE AN ELECTRODE ENCASED BY AT | | | LEAST 50 MM (2 IN.) OF CONCRETE, LOCATED WITHIN AND | | | NEAR THE BOTTOM OF A CONCRETE FOUNDATION OR FOOTING | | | THAT IS IN DIRECT CONTACT WITH THE EARTH, CONSISTING OF | | | AT LEAST 6.0 M (20 FT) OF ONE OR MORE BARE OR ZINC | | | GALVANIZED OR OTHER ELECTRICALLY CONDUCTIVE COATED | | | STEEL REINFORCING BARS OR RODS OF NOT LESS THAN 13 MM ( | | | 1/ 2 IN.) IN DIAMETER, OR CONSISTING OF AT LEAST 6.0 M | | | (20 FT) OF BARE COPPER CONDUCTOR NOT SMALLER THAN 4 | | | AWG. REINFORCING BARS SHALL BE PERMITTED TO BE BONDED | | | TOGETHER BY THE USUAL STEEL TIE WIRES OR OTHER | | | EFFECTIVE MEANS. | | | | | | 3} KITCHEN COUNTERTOP RECEPTACLES MUST BE GFI PROTECTED | | | PER 210.8(A)(6) GFI. INDICATE SAME ON THE PLANS. | | | | | | 4} SMOKE ALARMS MUST BE INSTALLED TO COMPLY WITH R313.2 | | | RESIDENTIAL FLORIDA BUILDING CODE.*** SEE BEDROOM #4 | | | FOR MISSING SMOKE ALARM. | | | | | | 5} 210.52(H) HALLWAYS IN DWELLING UNITS, HALLWAYS OF | | | 3.0 M (10 FT) OR MORE IN LENGTH SHALL HAVE AT LEAST ONE | | | RECEPTACLE OUTLET. | | | AS USED IN THIS SUBSECTION, THE HALL LENGTH SHALL BE | | | CONSIDERED THE LENGTH ALONG THE CENTERLINE OF THE HALL | | | WITHOUT PASSING THROUGH A DOORWAY. | | | | | | NOTE : SEE 230.70 (A)(1) IF THE SERVICE CONDUCTORS DO | | | NOT RUN FROM THE METER TO THE PANEL UNDERGROUND, A | | | DISCONNECT WOULD BE REQUIRED AT THE METER. | | | | | | .IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2009-12-21 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-12-21 |
Time |
09:29 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-12-21 |
Time |
09:29 |
Sent To |
|
|
| Notes |
| 2009-12-21 09:29:49 | SENT TO JULIO'S DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2009-10-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-10-20 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-10-20 |
Time |
16:19 |
Sent To |
|
|
| Notes |
| 2009-10-20 16:27:43 | TO R16.;'/WRT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2009-09-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-09-09 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-09-09 |
Time |
15:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2009-07-31 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-07-31 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-07-14 |
Time |
13:11 |
Sent To |
|
|
| Notes |
| 2009-07-14 13:11:23 | TO R-14 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2009-11-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-11-04 |
Time |
10:21 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-11-04 |
Time |
10:21 |
Sent To |
|
|
| Notes |
| 2009-11-04 10:22:10 | RECEIPT PR#: 09016563. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2009-10-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-10-02 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2009-10-02 11:45:36 | SEE NOTES FROM JULIO GOMEZ'S REVIEW. | | | STILL NEED COPY OF PAID RECEIPT. |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
P |
Date |
2009-11-04 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-11-04 |
Time |
16:22 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-11-04 |
Time |
16:22 |
Sent To |
|
|
| Notes |
| 2009-11-04 16:24:20 | ***LANDSCAPE REVIEW PASSED WITH PROVISO--NOTATED ON | | | PLAN*** | | | | | | 1. PROVIDE 120% IRRIGATION COVERAGE TO ALL LANDSCAPED | | | AREAS. | | | | | | 2. PROVIDE SOD AND IRRIGATION IN THE RIGHT-OF-WAY. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462. |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
2009-09-25 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-09-25 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-09-25 |
Time |
14:40 |
Sent To |
|
|
| Notes |
| 2009-09-25 14:52:42 | ***LANDSCAPE REVIEW FAILED*** | | | | | | 1. TO DETERMINE OPEN SPACE, YOU TAKE THE TOTAL LOT AREA | | | AND DEDUCT THE STRUCTURE. YOU DO NOT DEDUCT THE DRIVES | | | AND WALKWAYS. THEREFORE, THERE IS 3717 SQUARE FEET OF | | | OPEN SPACE. FOUR (4) TREES ARE REQUIRED AND EIGHT (8) | | | SHRUBS ARE REQUIRED | | | | | | 2. PLEASE PROVIDE A PLANT LIST AND IDENTIFY ALL | | | PROPOSED PLANT MATERIAL. THE SIZE, QUANTITY AND SPACING | | | SHALL BE INCLUDED. | | | | | | 3. THE IRRIGATION PLAN SHALL BE SEPARATE FROM THE | | | LANDSCAPE PLAN. | | | | | | 4. SHOW THE RIGHT-OF-WAY. SOD AND IRRIGATION IS | | | REQUIRED IN THE RIGHT-OF-WAY. | | | | | | 5. THE AIR CONDITIONING UNIT AND ANY OTHER MECHANICAL | | | EQUIPMENT AND GARBAGE CONTAINERS SHALL BE SCREENED. | | | | | | 6. ALL OF THE ITEMS LISTED IN SECTION 94-448 (D)(2), | | | SHALL BE SHOWN ON THE LANDSCAPE PLAN. | | | | | | 7. PROVIDE A COST ESTIMATE THAT INCLUDES THE TOTAL COST | | | OF ALL LANDSCAPE MATERIALS AND LABOR. IT SHALL BE | | | BROKEN DOWN INTO UNIT COST. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462, |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
2009-07-29 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-07-29 |
Time |
18:38 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-07-29 |
Time |
18:38 |
Sent To |
|
|
| Notes |
| 2009-07-29 18:46:05 | ***LANDSCAPE REVIEW FAILED*** | | | | | | 1. SUBMIT A COST ESTIMATE THAT INCLUDES THE TOTAL COST | | | OF ALL LANDSCAPE MATERIALS AND LABOR, BROKEN DOWN INTO | | | UNIT COST. | | | | | | 2. SUBMIT A LANDSCAPE PLAN BASED UPON THE REQUIREMENTS | | | SETFORTH IN ARTICLE XIV OF THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS. ALL ITEMS FOUND IN SECTION | | | 94-448 (D)(2) SHALL BE PART OF THE LANDSCAPE PLAN. | | | | | | 3. PLEASE PROVIDE THE TABULATION NECESSARY FOR THE | | | EVALUATION OF COMPLIANCE WITH ARTICLE XIV OF THE ZONING | | | AND LAND DEVELOPMENT REGULATIONS, INCLUDING THE | | | XERISCAPE DESIGN GUIDELINES. | | | | | | 4. AN IRRIGATION PERMIT IS REQUIRED. PLEASE SUBMIT A | | | PLAN WITH THE LAYOUT OF THE SYSTEM AND ALL COMPONENTS | | | IDENTIFIED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462. | | | | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
N |
Date |
2009-11-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-11-04 |
Time |
11:10 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-11-04 |
Time |
11:10 |
Sent To |
|
|
| Notes |
| 2009-11-04 11:12:19 | TALKED TO DON KULA. HE'LL SUBMIT THE MECHANICAL | | | INFORMATION UNDER A SEPARATE PERMIT. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2009-09-23 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-09-23 |
Time |
11:20 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-09-23 |
Time |
11:19 |
Sent To |
|
|
| Notes |
| 2009-09-23 11:19:58 | NO PLANS SUBMITTED AND NO PERMIT APPLIED FOR AT THIS | | | TIME. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2009-07-27 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-07-27 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-07-27 |
Time |
15:47 |
Sent To |
|
|
| Notes |
| 2009-07-27 15:56:58 | NO MECHANICAL PLANS SUBMITTED |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2009-09-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-09-14 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-09-14 |
Time |
14:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2009-07-23 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-07-23 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-07-23 |
Time |
11:15 |
Sent To |
|
|
| Notes |
| 2009-07-23 11:22:05 | DENIED | | | REFERENCE: | | | FBC-2004 RESIDENTIAL | | | FBC-2004 PLUMBING | | | | | | 1. SHT A-2 SANITARY RISER DIAGRAM. THE KITCHEN SINK | | | SHALL DISCHARGE DOWNSTREAM OF THE HORIZONTAL WET VENT | | | FOR THE BATHROOM FIXTURES. SECTION P3108.1. | | | | | | 2. SHT A-2 SANITARY RISER DIAGRAM. THE AUTOMATIC WASH | | | MACHINE SHALL CONNECT TO A BRANCH DRAIN OR DRAINAGE | | | STACK A MINIMUM OF 3 INCHES IN DIAMETER. SECTION 406.3. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2009-09-25 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2009-09-25 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2009-09-25 |
Time |
11:45 |
Sent To |
L |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2009-07-22 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2009-07-22 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2009-07-22 |
Time |
14:38 |
Sent To |
|
|
| Notes |
| 2009-07-22 14:50:50 | PLANNING AND ZONING DEPT: ***ZONING FAILED*** | | | | | | 1. PLEASE PROVIDE ALL RESPONSES IN WRITING. | | | | | | 2. PLEASE SUBMIT TWO (2) COPIES OF A LANDSCAPE PLAN | | | SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF | | | THE CITY OF WEST PALM BEACH ZONING AND LAND DEVELOPMENT | | | REGULATIONS (ZLDR). | | | | | | 3. INDICATE THE SETBACK DIMENSIONS FROM ANY EXTERIOR | | | IMPROVEMENTS TO ALL ADJACENT PROPERTY LINES. PURSUANT | | | TO THE ZLDR, SECTION 94-72(A)(2): SINGLE-FAMILY LOW | | | DENSITY (SF7) RESIDENTIAL DISTRICT - MINIMUM SETBACKS | | | FOR PRINCIPAL BUILDING ARE AS FOLLOWS: | | | | | | A. FRONT: 25 FEET; | | | | | | B. CORNER: 12.5 FEET; | | | | | | C. REAR: 15 FEET OR TEN PERCENT OF LOT DEPTH, WHICHEVER | | | IS LESS; | | | | | | D. SIDE: FIVE FEET MINIMUM, 15 FEET TOTAL. | | | | | | **THE REAR AND FRONT SETBACKS SHOWN ON THE SUBMITTED | | | PLAN IS NOT FROM THE PORCH OR REAR ATTACHED ENCLOSED | | | STRUCTURE.** | | | | | | 4. PROVIDE THE TOTAL HEIGHT OF THE PROPOSED ADDITION ON | | | THE ELEVATION PLAN. PURSUANT TO THE ZLDR, SECTION | | | 94-611, THE HEIGHT SHALL BE MEASURED AS THE VERTICAL | | | DISTANCE FROM THE AVERAGE ELEVATION OF THE FINISHED | | | GRADE OF THE BUILDING TO THE MEAN HEIGHT LEVEL BETWEEN | | | EAVES AND RIDGE FOR GABLE, HIP, AND GAMBREL ROOFS. | | | (MAXIMUM HEIGHT IS 30 FEET.) | | | | | | 5. INDICATE SETBACK DIMENSIONS FROM PROPOSED/RELOCATED | | | A/C EQUIPMENT TO ALL PROPERTY LINES. PURSUANT THE ZLDR, | | | SECTION 94-305(B)(4): MECHANICAL EQUIPMENT MAY NOT | | | PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK. | | | | | | 6. PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND | | | LAND DEVELOPMENT REGULATIONS (ZLDR), SECTION 94-482(A): | | | REQUIRED OFF-STREET PARKING SPACES FOR LESS THAN FOUR | | | RESIDENTIAL DWELLING UNITS SHALL BE LOCATED ON THE | | | PROPERTY ON WHICH THE UNITS ARE CONSTRUCTED. REQUIRED | | | PARKING MAY BE LOCATED IN A FRONT YARD; HOWEVER, THE | | | LESSER OF 1,000 SQUARE FEET OR 75 PERCENT OF THE FRONT | | | YARD AREA MUST BE LANDSCAPED. PARKING AREAS LOCATED IN | | | THE FRONT YARD SHALL BE SURFACED WITH A SMOOTH, | | | NONDUSTING SURFACE IN COMPLIANCE WITH SUBSECTION | | | 33-485(E). IT SHALL BE A VIOLATION OF THIS CHAPTER TO | | | PARK ON ANY UNPAVED AREAS AS DESCRIBED IN THIS ARTICLE. | | | | | | PLEASE INDICATE SQUARE FOOTAGE OF ALL IMPERMEABLE | | | SURFACES (EXISTING AND PROPOSED) LOCATED WITHIN THE | | | FRONT YARD (FROM FRONT PROPERTY LINE TO THE FRONT | | | BUILDING FACADE). | | | | | | ADDITIONALLY, A RIGHT-OF-WAY PERMIT WILL NEED TO BE | | | ACQUIRED FROM THE CITY'S ENGINEERING DEPARTMENT | | | (561.494.1040), FOR THE PROPOSED APPROACH | | | EXTENSION.**DO NOT RESUBMIT WITHOUT THIS APPROVAL** | | | | | | NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY | | | GENERATE ADDITIONAL COMMENTS. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1444 OR (561) 805-6720 | | | E-MAIL: [email protected] | | | | | | SENT BACK TO R14 | | | |
|
|