Plan Review Details - Permit 09070203
Plan Review Stops For Permit 09070203
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status N Date 2010-03-23 Cont ID  
Sent By jgomez Date 2010-03-23 Time 11:29 Rev Time 0.00
Received By jgomez Date 2010-03-23 Time 10:51 Sent To  
Notes
2010-03-23 11:31:25MET WITH DON KULA. HE SAID THEY INSTALLED WINDOWS WITH
 NOA 05-0516.03. THIS WINDOW WAS APPROVED ON 11/04/09
 AND MEETS THE DESIGN PRESSURES CALCULATED BY THE
 ARCHITECT. NO REVISION REQUIRED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2009-11-12 Cont ID  
Sent By jgomez Date 2009-11-12 Time 13:03 Rev Time 0.00
Received By jgomez Date 2009-11-12 Time 13:03 Sent To PC
Notes
2009-11-12 13:04:50ONE SET OF PLANS SUBMITTED FOR RE-STAMPING.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-11-04 Cont ID  
Sent By jgomez Date 2009-11-04 Time 14:10 Rev Time 0.00
Received By jgomez Date 2009-11-04 Time 10:39 Sent To  
Notes
2009-11-04 14:10:58BUILDING REVIEW APPROVED WITH PROVISO:
  
 1- REVISE LEGAL DESCRIPTION AND SITE DATA ON SHEET A-1.
 PROVIDE CORRECT INFORMATION.
  
 2- PROVIDE PRODUCT APPROVALS FOR SINGLE HUNG WINDOWS
 THAT MEET THE DESIGN PRESSURES CALCULATED BY THE
 ARCHITECT.
  
 3- PROVIDE PRODUCT APPROVAL FOR WINDOW MULLIONS.
  
 4- STORM SHUTTERS:
 A) PROVIDE PRODUCT APPROVALS THAT MEET THE DESIGN
 PRESSURES CALCULATED BY THE ARCHITECT.
 B) PROVIDE COMPLETE INSTALLATION SCHEDULE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-09-21 Cont ID  
Sent By jgomez Date 2009-09-21 Time 10:02 Rev Time 0.00
Received By jgomez Date 2009-09-17 Time 11:04 Sent To  
Notes
2009-09-21 10:02:39BUILDING REVIEW APPROVED WITH PROVISO:
  
 1- REVISE LEGAL DESCRIPTION AND SITE DATA ON SHEET A-1.
 PROVIDE CORRECT INFORMATION.
  
 2- PROVIDE PRODUCT APPROVALS FOR SINGLE HUNG WINDOWS
 THAT MEET THE DESIGN PRESSURES CALCULATED BY THE
 ARCHITECT.
  
 3- PROVIDE PRODUCT APPROVAL FOR WINDOW MULLIONS.
  
 4- STORM SHUTTERS:
 A) PROVIDE PRODUCT APPROVALS THAT MEET THE DESIGN
 PRESSURES CALCULATED BY THE ARCHITECT.
 B) PROVIDE COMPLETE INSTALLATION SCHEDULE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-07-31 Cont ID  
Sent By jgomez Date 2009-07-31 Time 12:41 Rev Time 0.00
Received By jgomez Date 2009-07-31 Time 12:41 Sent To  
Notes
2009-07-31 12:52:51NEW SF RESIDENCE (R3), BUILDING REVIEW CHECKLIST.
 2007 FLORIDA RESIDENTIAL CODE WITH 2009 REVISIONS.
  
 1- NEED RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13
 FLORIDA STATUTE.
 NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK UP.
  
 2- BRING PLANS TO PALM BEACH COUNTY FOR IMPACT FEES.
 BRING BACK STAMPED PLANS AND COPY OF PAID RECEIPT.
  
 3- SHEET A-1: PROVIDE DRAINAGE PLAN. SEC. R401.3 OF
 2007 FLORIDA RESIDENTIAL CODE. SHOW ON SITE PLAN
 DRAINAGE OF WATER BY USING ARROWS SHOWING DIRECTION OF
 WATER. WATER CAN'T BE DIVERTED TO THE NEIGHBOR'S
 PROPERTY.
  
 4- SHEET A-2:
 A) ACCORDING TO SEC. R301.2.1.4.3 OF 2009 REVISIONS TO
 THE 2007 FLORIDA RESIDENTIAL CODE THIS BUILDING IS
 LOCATED ON EXPOSURE "C" NOT "B". REVISE DESIGN DATA
 NOTE #7 AND WIND DESIGN INFORMATION. ALSO, REVISE ALL
 DESIGN PRESSURES FOR COMPONENTS AND CLADDING.
  
 B) PROVIDE AREA TABULATIONS. EX: A/C AREA, STORAGE,
 PORCH TO PROPERLY ASSESS RADON AND BUILDING VALUATION
 SEC. 108.3 CITY AMENDMENTS TO FBC.
  
 5- SHEET A-3:
 A) PROVIDE DOOR AND WINDOW SCHEDULE OR SPECIFY SIZE OF
 DOORS/WINDOWS ON FLOOR PLAN TO VERIFY COMPLIANCE WITH
 THE EGRESS REQUIREMENTS OF SEC. R310 AND R311. AND TO
 VERIFY COMPLIANCE WITH BATHROOM DOOR MIN. SIZE.
  
 B) REVISE DOORS AND WINDOWS DESIGN PRESSURES.
 COORDINATE WITH ITEM #4 ABOVE.
  
 6- SHEET A-4:
 A) REVISE ROOF SHEATHING NOTES SHOWN ON THE WALL
 SECTIONS. NEED TO USE MIN. 8D RING SHANK NAILS AND THEY
 NEED TO BE MIN. 4"O.C. ON ROOF ZONE 3. AS REQUIRED BY
 SEC. R803.2.3.1 AND FIGURE R803.2.3.1 OF 2007 FLORIDA
 RESIDENTIAL CODE.
  
 B) FRONT ELEVATION DOESN'T MATCH FLOOR PLAN.
  
 C) COORDINATE SPECIFICATIONS SHOWN ON WALL SECTIONS FOR
 WALL TO ROOF TRUSS ATTACHMENT TO MATCH ROOF FRAMING
 PLAN SPECIFICATIONS.
  
 D) PROVIDE COMPLETE SPECIFICATIONS ON WALL SECTIONS FOR
 ATTIC VENTILATION TO SHOW COMPLIANCE WITH SEC. R806.
 SPECIFY SIZE AND LOCATION OF VENTS.
  
 E) REVISE INSULATION VALUE SHOWN ON WALL SECTION TO
 MATCH ENERGY CALCULATIONS. ALSO, R19 DOESN'T FIT ON 2X4
 WALL. REVISE AS REQUIRED.
  
 F) SEC. 8/A-4: SPECIFY STUCCO THICKNESS AS REQUIRED BY
 SE TABLE R702.1(1) OF 2007 FLORIDA RESIDENTIAL CODE.
 ALSO, REQUIRES 2 LAYERS OF VAPOR BARRIER AS REQUIRED BY
 SEC. R703.6.3.
  
 G) SECTION 7/A-4: PROVIDE DETAIL/SPECIFICATIONS FOR
 PREPARATION OF OPENINGS TO RECEIVE STORM SHUTTERS.
  
 H) SEC. 9/A-4: SPECIFY LOCATION OF VENTS. SEC. R806
 2007 FLORIDA RESIDENTIAL CODE.
  
 7- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE
 9B-72 FOR:
 A) WINDOW MULLIONS AS SHOWN ON PLANS. AND, CLEARLY MARK
 SPECIFIC MULLION SIZE TO VERIFY COMPLIANCE WITH THE
 CALCULATED DESIGN PRESSURES.
  
 B) SINGLE HUNG WINDOWS: NEED TO PROVIDE CURRENT FLORIDA
 PRODUCT APPROVAL FL4065-R5 AND CORRESPONDING DRAWINGS.
 PRODUCT APPROVAL SUBMITTED FL4065.1 R3 IS NOT THE MOST
 CURRENT ONE.
  
 8- ARCHITECT OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC.
  
 9- ENERGY CALCULATIONS SUBMITTED.
 A) COMPLETE ALL THE INFORMATION ON TOP OF FORM
 INCLUDING THE SPECIFIC ADDRESS WHEN APPLYING FOR
 PERMIT.
  
 B) OWNER/AGENT TO SIGN AND DATE BOTTOM OF FORM TO
 CERTIFY COMPLIANCE WITH THE CODE.
  
 C) COMPLETE ALL THE INFORMATION ON THE CODE COMPLIANCE
 CHECKLIST PAGE. NOTHING WAS CHECKED.
  
 10- STORM SHUTTERS: PROVIDE COMPLETE INSTALLATION
 SCHEDULE. SEE ATTACHED SAMPLE. AND, CLEARLY MARK ON
 SHUTTERS DRAWINGS SPECIFIC MOUNTING CONDITIONS (EX;
 WALL MOUNTED, BUILT OUT, ETC) AND SPECIFIC ANCHOR TYPE
 AND SPACING TO BE USED TO VERIFY COMPLIANCE WITH THE
 CALCULATED DESIGN PRESSURES OF SEC. R301 OF 2007
 FLORIDA RESIDENTIAL CODE.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2009-12-22 Cont ID  
Sent By dpalmer Date 2009-12-22 Time 16:03 Rev Time 0.00
Received By dpalmer Date 2009-12-22 Time 16:03 Sent To  
Notes
2009-12-22 16:05:34*DENIED **
  
 1) NOTE: ORIGINAL PROVISO FROM 10/2 HAS STILL NOT BEEN
 ADDRESSED. PLANS SUBMITTED TWICE WITHOUT CORRECTIONS
 MADE TO ELECTRICAL.
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2009-10-26 Cont ID  
Sent By dpalmer Date 2009-10-26 Time 14:17 Rev Time 0.00
Received By dpalmer Date 2009-10-26 Time 14:16 Sent To  
Notes
2009-10-26 14:16:54SAME PROVISO AS PREVIOUS NOTES.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2009-10-02 Cont ID  
Sent By dpalmer Date 2009-10-02 Time 12:02 Rev Time 0.00
Received By dpalmer Date 2009-10-02 Time 12:02 Sent To  
Notes
2009-10-02 12:04:13** PROVISO **
  
 1) NOTE: THE PLANS STATE A 2006 EDITION OF NFPA-70 (
 NEC).
 THE PROJECT IS SUBMITTED UNDER THE 2005 NEC. THE NEXT
 CODE IN EFFECT WILL BE THE 2008 NEC.
  
 2) NOTE: FOOTER STEEL IS MISSING FROM GROUNDING
 ELECTRODE SYSTEM. 250.50 PLANS STATE THAT CONCRETE IS
 FIBER REINFORCED HOWEVER BASED ON STRUCTURAL PLANS
 THERE ARE 3-#5 BARS IN FOOTERS.
  
 3) NOTE: STORAGE TYPE WATER HEATERS ARE CONTINUOUS LOAD
 WHICH REQUIRES LOAD TO BE FIGURED AT 125%.
  
 4) NOTE: PLANS STILL INDICATE SMOKE DETECTORS INSTEAD
 OF SMOKE ALARMS. PLEASE SEE NFPA-72 11.5.1, 11.8.3
  
 5) NOTE: PLANS/TITLE BLOCKS DO NOT CONTAIN ANY ADDRESS
 ON TITLE BLOCKS. FAC 61G1-16.004. FBC 106.5 FOR RECORD
 PLANS. THIS WAS REDLINED ON ELECTRICAL SHEETS.
  
 6) NOTE: WASHER LOAD SHALL BE 1.5/1500VA MINIMUM PER
 220.52
  
 ** PLEASE REVISE PLANS BEFORE ROUGH ALONG WITH ANY
 OTHER REVISIONS.
  
 **IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2009-07-28 Cont ID  
Sent By btrobaug Date 2009-07-28 Time 16:54 Rev Time 0.00
Received By btrobaug Date 2009-07-28 Time 16:01 Sent To  
Notes
2009-07-28 16:30:55 
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2007 FLORIDA RESIDENTIAL BUILDING CODE, 2009
 REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND
 FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 1} RECEPTACLE SPACING MUST COMPLY WITH 210.52(A)(1) AND
 210.52(A)(2). 2005 NEC. SEE REVIEWED PLAN FOR
 DEFICIENCIES.***BEDROOM #1.
  
 2} 250.50 GROUNDING ELECTRODE SYSTEM
 ALL GROUNDING ELECTRODES AS DESCRIBED IN 250.52(A)(1)
 THROUGH (A)(6) THAT ARE PRESENT AT EACH BUILDING OR
 STRUCTURE SERVED SHALL BE BONDED TOGETHER TO FORM THE
 GROUNDING ELECTRODE SYSTEM. WHERE NONE OF THESE
 GROUNDING ELECTRODES EXIST, ONE OR MORE OF THE
 GROUNDING ELECTRODES SPECIFIED IN 250.52(A)(4) THROUGH
 (A)(7) SHALL BE INSTALLED AND USED.250.52(A)(3)
 CONCRETE-ENCASED ELECTRODE AN ELECTRODE ENCASED BY AT
 LEAST 50 MM (2 IN.) OF CONCRETE, LOCATED WITHIN AND
 NEAR THE BOTTOM OF A CONCRETE FOUNDATION OR FOOTING
 THAT IS IN DIRECT CONTACT WITH THE EARTH, CONSISTING OF
 AT LEAST 6.0 M (20 FT) OF ONE OR MORE BARE OR ZINC
 GALVANIZED OR OTHER ELECTRICALLY CONDUCTIVE COATED
 STEEL REINFORCING BARS OR RODS OF NOT LESS THAN 13 MM (
 1/ 2 IN.) IN DIAMETER, OR CONSISTING OF AT LEAST 6.0 M
 (20 FT) OF BARE COPPER CONDUCTOR NOT SMALLER THAN 4
 AWG. REINFORCING BARS SHALL BE PERMITTED TO BE BONDED
 TOGETHER BY THE USUAL STEEL TIE WIRES OR OTHER
 EFFECTIVE MEANS.
  
 3} KITCHEN COUNTERTOP RECEPTACLES MUST BE GFI PROTECTED
 PER 210.8(A)(6) GFI. INDICATE SAME ON THE PLANS.
  
 4} SMOKE ALARMS MUST BE INSTALLED TO COMPLY WITH R313.2
 RESIDENTIAL FLORIDA BUILDING CODE.*** SEE BEDROOM #4
 FOR MISSING SMOKE ALARM.
  
 5} 210.52(H) HALLWAYS IN DWELLING UNITS, HALLWAYS OF
 3.0 M (10 FT) OR MORE IN LENGTH SHALL HAVE AT LEAST ONE
 RECEPTACLE OUTLET.
 AS USED IN THIS SUBSECTION, THE HALL LENGTH SHALL BE
 CONSIDERED THE LENGTH ALONG THE CENTERLINE OF THE HALL
 WITHOUT PASSING THROUGH A DOORWAY.
  
 NOTE : SEE 230.70 (A)(1) IF THE SERVICE CONDUCTORS DO
 NOT RUN FROM THE METER TO THE PANEL UNDERGROUND, A
 DISCONNECT WOULD BE REQUIRED AT THE METER.
  
 .IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2009-12-21 Cont ID  
Sent By jgomez Date 2009-12-21 Time 09:29 Rev Time 0.00
Received By jgomez Date 2009-12-21 Time 09:29 Sent To  
Notes
2009-12-21 09:29:49SENT TO JULIO'S DESK.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2009-10-20 Cont ID  
Sent By btrobaug Date 2009-10-20 Time 16:27 Rev Time 0.00
Received By btrobaug Date 2009-10-20 Time 16:19 Sent To  
Notes
2009-10-20 16:27:43TO R16.;'/WRT.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-09-09 Cont ID  
Sent By shill Date 2009-09-09 Time 15:06 Rev Time 0.00
Received By shill Date 2009-09-09 Time 15:06 Sent To  
Notes
2009-09-09 15:06:27R3
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-07-31 Cont ID  
Sent By jgomez Date 2009-07-31 Time 13:32 Rev Time 0.00
Received By jgomez Date 2009-07-14 Time 13:11 Sent To  
Notes
2009-07-14 13:11:23TO R-14

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2009-11-04 Cont ID  
Sent By jgomez Date 2009-11-04 Time 10:21 Rev Time 0.00
Received By jgomez Date 2009-11-04 Time 10:21 Sent To  
Notes
2009-11-04 10:22:10RECEIPT PR#: 09016563.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2009-10-02 Cont ID  
Sent By dpalmer Date 2009-10-02 Time 11:45 Rev Time 0.00
Received By dpalmer Date   Time   Sent To  
Notes
2009-10-02 11:45:36SEE NOTES FROM JULIO GOMEZ'S REVIEW.
 STILL NEED COPY OF PAID RECEIPT.

Review Stop L LANDSCAPING
Rev No 3 Status P Date 2009-11-04 Cont ID  
Sent By rkussner Date 2009-11-04 Time 16:22 Rev Time 0.00
Received By rkussner Date 2009-11-04 Time 16:22 Sent To  
Notes
2009-11-04 16:24:20***LANDSCAPE REVIEW PASSED WITH PROVISO--NOTATED ON
 PLAN***
  
 1. PROVIDE 120% IRRIGATION COVERAGE TO ALL LANDSCAPED
 AREAS.
  
 2. PROVIDE SOD AND IRRIGATION IN THE RIGHT-OF-WAY.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.

Review Stop L LANDSCAPING
Rev No 2 Status F Date 2009-09-25 Cont ID  
Sent By rkussner Date 2009-09-25 Time 14:40 Rev Time 0.00
Received By rkussner Date 2009-09-25 Time 14:40 Sent To  
Notes
2009-09-25 14:52:42***LANDSCAPE REVIEW FAILED***
  
 1. TO DETERMINE OPEN SPACE, YOU TAKE THE TOTAL LOT AREA
 AND DEDUCT THE STRUCTURE. YOU DO NOT DEDUCT THE DRIVES
 AND WALKWAYS. THEREFORE, THERE IS 3717 SQUARE FEET OF
 OPEN SPACE. FOUR (4) TREES ARE REQUIRED AND EIGHT (8)
 SHRUBS ARE REQUIRED
  
 2. PLEASE PROVIDE A PLANT LIST AND IDENTIFY ALL
 PROPOSED PLANT MATERIAL. THE SIZE, QUANTITY AND SPACING
 SHALL BE INCLUDED.
  
 3. THE IRRIGATION PLAN SHALL BE SEPARATE FROM THE
 LANDSCAPE PLAN.
  
 4. SHOW THE RIGHT-OF-WAY. SOD AND IRRIGATION IS
 REQUIRED IN THE RIGHT-OF-WAY.
  
 5. THE AIR CONDITIONING UNIT AND ANY OTHER MECHANICAL
 EQUIPMENT AND GARBAGE CONTAINERS SHALL BE SCREENED.
  
 6. ALL OF THE ITEMS LISTED IN SECTION 94-448 (D)(2),
 SHALL BE SHOWN ON THE LANDSCAPE PLAN.
  
 7. PROVIDE A COST ESTIMATE THAT INCLUDES THE TOTAL COST
 OF ALL LANDSCAPE MATERIALS AND LABOR. IT SHALL BE
 BROKEN DOWN INTO UNIT COST.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462,

Review Stop L LANDSCAPING
Rev No 1 Status F Date 2009-07-29 Cont ID  
Sent By rkussner Date 2009-07-29 Time 18:38 Rev Time 0.00
Received By rkussner Date 2009-07-29 Time 18:38 Sent To  
Notes
2009-07-29 18:46:05***LANDSCAPE REVIEW FAILED***
  
 1. SUBMIT A COST ESTIMATE THAT INCLUDES THE TOTAL COST
 OF ALL LANDSCAPE MATERIALS AND LABOR, BROKEN DOWN INTO
 UNIT COST.
  
 2. SUBMIT A LANDSCAPE PLAN BASED UPON THE REQUIREMENTS
 SETFORTH IN ARTICLE XIV OF THE ZONING AND LAND
 DEVELOPMENT REGULATIONS. ALL ITEMS FOUND IN SECTION
 94-448 (D)(2) SHALL BE PART OF THE LANDSCAPE PLAN.
  
 3. PLEASE PROVIDE THE TABULATION NECESSARY FOR THE
 EVALUATION OF COMPLIANCE WITH ARTICLE XIV OF THE ZONING
 AND LAND DEVELOPMENT REGULATIONS, INCLUDING THE
 XERISCAPE DESIGN GUIDELINES.
  
 4. AN IRRIGATION PERMIT IS REQUIRED. PLEASE SUBMIT A
 PLAN WITH THE LAYOUT OF THE SYSTEM AND ALL COMPONENTS
 IDENTIFIED.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.
  
  
  
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status N Date 2009-11-04 Cont ID  
Sent By jgomez Date 2009-11-04 Time 11:10 Rev Time 0.00
Received By jgomez Date 2009-11-04 Time 11:10 Sent To  
Notes
2009-11-04 11:12:19TALKED TO DON KULA. HE'LL SUBMIT THE MECHANICAL
 INFORMATION UNDER A SEPARATE PERMIT.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2009-09-23 Cont ID  
Sent By rregueir Date 2009-09-23 Time 11:20 Rev Time 0.00
Received By rregueir Date 2009-09-23 Time 11:19 Sent To  
Notes
2009-09-23 11:19:58NO PLANS SUBMITTED AND NO PERMIT APPLIED FOR AT THIS
 TIME.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2009-07-27 Cont ID  
Sent By rregueir Date 2009-07-27 Time 15:57 Rev Time 0.00
Received By rregueir Date 2009-07-27 Time 15:47 Sent To  
Notes
2009-07-27 15:56:58NO MECHANICAL PLANS SUBMITTED

Review Stop P PLUMBING
Rev No 2 Status P Date 2009-09-14 Cont ID  
Sent By kstevens Date 2009-09-14 Time 14:16 Rev Time 0.00
Received By kstevens Date 2009-09-14 Time 14:16 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2009-07-23 Cont ID  
Sent By kstevens Date 2009-07-23 Time 11:15 Rev Time 0.00
Received By kstevens Date 2009-07-23 Time 11:15 Sent To  
Notes
2009-07-23 11:22:05DENIED
 REFERENCE:
 FBC-2004 RESIDENTIAL
 FBC-2004 PLUMBING
  
 1. SHT A-2 SANITARY RISER DIAGRAM. THE KITCHEN SINK
 SHALL DISCHARGE DOWNSTREAM OF THE HORIZONTAL WET VENT
 FOR THE BATHROOM FIXTURES. SECTION P3108.1.
  
 2. SHT A-2 SANITARY RISER DIAGRAM. THE AUTOMATIC WASH
 MACHINE SHALL CONNECT TO A BRANCH DRAIN OR DRAINAGE
 STACK A MINIMUM OF 3 INCHES IN DIAMETER. SECTION 406.3.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2009-09-25 Cont ID  
Sent By astelly Date 2009-09-25 Time 11:45 Rev Time 0.00
Received By astelly Date 2009-09-25 Time 11:45 Sent To L
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2009-07-22 Cont ID  
Sent By mcruz Date 2009-07-22 Time 14:50 Rev Time 0.00
Received By mcruz Date 2009-07-22 Time 14:38 Sent To  
Notes
2009-07-22 14:50:50PLANNING AND ZONING DEPT: ***ZONING FAILED***
  
 1. PLEASE PROVIDE ALL RESPONSES IN WRITING.
  
 2. PLEASE SUBMIT TWO (2) COPIES OF A LANDSCAPE PLAN
 SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF
 THE CITY OF WEST PALM BEACH ZONING AND LAND DEVELOPMENT
 REGULATIONS (ZLDR).
  
 3. INDICATE THE SETBACK DIMENSIONS FROM ANY EXTERIOR
 IMPROVEMENTS TO ALL ADJACENT PROPERTY LINES. PURSUANT
 TO THE ZLDR, SECTION 94-72(A)(2): SINGLE-FAMILY LOW
 DENSITY (SF7) RESIDENTIAL DISTRICT - MINIMUM SETBACKS
 FOR PRINCIPAL BUILDING ARE AS FOLLOWS:
  
 A. FRONT: 25 FEET;
  
 B. CORNER: 12.5 FEET;
  
 C. REAR: 15 FEET OR TEN PERCENT OF LOT DEPTH, WHICHEVER
 IS LESS;
  
 D. SIDE: FIVE FEET MINIMUM, 15 FEET TOTAL.
  
 **THE REAR AND FRONT SETBACKS SHOWN ON THE SUBMITTED
 PLAN IS NOT FROM THE PORCH OR REAR ATTACHED ENCLOSED
 STRUCTURE.**
  
 4. PROVIDE THE TOTAL HEIGHT OF THE PROPOSED ADDITION ON
 THE ELEVATION PLAN. PURSUANT TO THE ZLDR, SECTION
 94-611, THE HEIGHT SHALL BE MEASURED AS THE VERTICAL
 DISTANCE FROM THE AVERAGE ELEVATION OF THE FINISHED
 GRADE OF THE BUILDING TO THE MEAN HEIGHT LEVEL BETWEEN
 EAVES AND RIDGE FOR GABLE, HIP, AND GAMBREL ROOFS.
 (MAXIMUM HEIGHT IS 30 FEET.)
  
 5. INDICATE SETBACK DIMENSIONS FROM PROPOSED/RELOCATED
 A/C EQUIPMENT TO ALL PROPERTY LINES. PURSUANT THE ZLDR,
 SECTION 94-305(B)(4): MECHANICAL EQUIPMENT MAY NOT
 PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK.
  
 6. PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND
 LAND DEVELOPMENT REGULATIONS (ZLDR), SECTION 94-482(A):
 REQUIRED OFF-STREET PARKING SPACES FOR LESS THAN FOUR
 RESIDENTIAL DWELLING UNITS SHALL BE LOCATED ON THE
 PROPERTY ON WHICH THE UNITS ARE CONSTRUCTED. REQUIRED
 PARKING MAY BE LOCATED IN A FRONT YARD; HOWEVER, THE
 LESSER OF 1,000 SQUARE FEET OR 75 PERCENT OF THE FRONT
 YARD AREA MUST BE LANDSCAPED. PARKING AREAS LOCATED IN
 THE FRONT YARD SHALL BE SURFACED WITH A SMOOTH,
 NONDUSTING SURFACE IN COMPLIANCE WITH SUBSECTION
 33-485(E). IT SHALL BE A VIOLATION OF THIS CHAPTER TO
 PARK ON ANY UNPAVED AREAS AS DESCRIBED IN THIS ARTICLE.
  
 PLEASE INDICATE SQUARE FOOTAGE OF ALL IMPERMEABLE
 SURFACES (EXISTING AND PROPOSED) LOCATED WITHIN THE
 FRONT YARD (FROM FRONT PROPERTY LINE TO THE FRONT
 BUILDING FACADE).
  
 ADDITIONALLY, A RIGHT-OF-WAY PERMIT WILL NEED TO BE
 ACQUIRED FROM THE CITY'S ENGINEERING DEPARTMENT
 (561.494.1040), FOR THE PROPOSED APPROACH
 EXTENSION.**DO NOT RESUBMIT WITHOUT THIS APPROVAL**
  
 NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY
 GENERATE ADDITIONAL COMMENTS.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  
 SENT BACK TO R14
  


Account Summary | Usage Policy | Privacy Policy