Rev No 1 Status F Date 2009-07-23 Cont ID  
Sent By jwitmer Date 2009-07-23 Time 13:03 Rev Time 0.00
Received By jwitmer Date 2009-07-23 Time 13:02 Sent To  
Notes
2009-07-23 13:05:34BUILDING PLAN REVIEW
 PERMIT: 09070118
 ADD: 3400 N FLAGLER DR
 CONT: O/B SANDERSON, FREDA
 TEL: (561)655-2012
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER
 MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC
 BUILDING WITH 2009 SUPPLEMENTS.
  
 2) PLEASE PROVIDE A PUNCH LIST OF ITEMS THAT ARE TO BE
 COVERED UNDER THIS PERMIT APPLICATION.
  
 3) NOT KNOWING THE SCOPE OF WORK UNDER THIS PERMIT THIS
 MAY OR MAY NOT APPLY, 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL-FORCE-RESISTING SYSTEM OF THE
 BUILDING:
 3.1. BASIC WIND SPEED (3-SECOND GUST), MILES PER HOUR
 (KM/HR).
  
 3.2. WIND IMPORTANCE FACTOR, I W , AND BUILDING
 CLASSIFICATION FROM TABLE 1604.5 OR TABLE 6-1, ASCE 7
 AND BUILDING CLASSIFICATION IN TABLE 1-1, ASCE 7.
  
 3.3. WIND EXPOSURE, IF MORE THAN ONE WIND EXPOSURE IS
 UTILIZED, THE WIND EXPOSURE AND APPLICABLE WIND
 DIRECTION SHALL BE INDICATED.
  
 3.4. THE APPLICABLE ENCLOSURE CLASSIFICATIONS AND, IF
 DESIGNING WITH ASCE 7, INTERNAL PRESSURE COEFFICIENT.
  
 3.5. COMPONENTS AND CLADDING. THE DESIGN WIND PRESSURES
 IN TERMS OF PSF (KN/M 2 ) TO BE USED FOR THE SELECTION
 OF EXTERIOR COMPONENTS AND CLADDING MATERIALS NOT
 SPECIFICALLY DESIGNED BY THE REGISTERED DESIGN
 PROFESSIONAL.
  
 A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
 SURVEY:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2009-07-28 Cont ID  
Sent By btrobaug Date 2009-07-28 Time 15:09 Rev Time 0.00
Received By btrobaug Date 2009-07-27 Time 15:28 Sent To  
Notes
2009-07-28 14:27:20 
  
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2007 FLORIDA RESIDENTIAL BUILDING CODE, 2009
 REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND
 FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 1} } PROVIDE A RISER DIAGRAM WITH CONDUCTOR AND CONDUIT
 SIZE AND TYPE, GROUNDING DETAILS, LOAD CALCULATIONS,
 PANEL SCHEDULES PER 106.3.5.4 FBC. 215.5 NEC
  
 2} THERE IS AN ATS SHOWN WITH THE SERVICE PANELS ON
 SHEET E3, NOTE THAT A SEPARATE PERMIT IS REQUIRED FOR A
 GENERATOR.THE ATS MAY BE INSTLLED WITH THE SERVICE
 EQUIPMENT BUT SPECS MUST BE PROVIDED WITH THE GENERATOR
 APPLICATION.
  
 PLEASE NOTE AN ELECTRICAL PERMIT IS REQUIRED FOR THE
 SCOPE OF WORK PURPOSED. 105.1 FBC AS AMENDED. A
 CONTRACTOR IS SIGNED ON THE PERMIT APPLICATION BUT WAS
 NOT ASSIGNED A PERMIT NUMBER.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-08-05 Cont ID  
Sent By jwitmer Date 2009-08-05 Time 11:50 Rev Time 0.00
Received By jwitmer Date 2009-07-09 Time 08:31 Sent To  
Notes
2009-07-09 08:31:36TO R-16

Review Stop L LANDSCAPING
Rev No 1 Status F Date 2009-07-13 Cont ID  
Sent By rkussner Date 2009-07-13 Time 16:33 Rev Time 0.00
Received By rkussner Date 2009-07-13 Time 16:33 Sent To  
Notes
2009-07-13 16:44:24***LANDSCAPE REVIEW FAILED***
  
 PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN WRITTEN
 FORMAT.
  
 1. SUBMIT COST ESTIMATE THAT INCLUDES THE TOTAL COST OF
 ALL LANDSCAPE MATERIALS AND LABOR. IT SHALL BE BROKEN
 DOWN INTO UNIT COST.
  
 2. SUBMIT A LANDSCAPE PLAN AND THE TABULATION NECESSARY
 FOR THE EVALUATION OF COMPLIANCE WITH ARTICLE XIV OF
 THE ZONING AND LAND DEVELOPMENT REGULAITONS, INCLUDING
 THE XERISCAPE POINT OPTIONS. THE PLAN SUBMITTED WAS
 CONCEPTUAL.
  
 3. PURSUANT TO SECTION 94-448 (D)(2), THE LANDSCAPE
 PLAN SHALL INCLUDE ALL OF THE ELEMENTS LISTED IN THIS
 SECTION.
  
 4. A TREE ALTERATION PERMIT SHALL BE REQUIRED IF ANY
 TREES WILL BE RELOCATED OR REMOVED. THE APPLICATION CAN
 BE FOUND AT THE FRONT DESK OF THE PLANNING AND ZONING
 DEPARTMENT.
  
 4. ALL EXISTING TREES, SHRUBS AND GROUND COVER TO
 REMAIN SHALL BE IDENTIFIED ON THE LANDSCAPE PLAN. ALL
 PLANT MATERIAL TO REMAIN SHALL BE FLORIDA #1 GRADE OR
 BETTER.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.
  
  
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2009-07-27 Cont ID  
Sent By rregueir Date 2009-07-27 Time 14:25 Rev Time 0.00
Received By rregueir Date 2009-07-27 Time 13:53 Sent To  
Notes
2009-07-27 14:26:03ROUGH INSPECTIONS PERFORMED UNDER PERMIT #03091230

Review Stop P PLUMBING
Rev No 1 Status F Date 2009-08-05 Cont ID  
Sent By jwitmer Date 2009-08-05 Time 11:48 Rev Time 0.50
Received By jwitmer Date 2009-08-05 Time 11:47 Sent To  
Notes
2009-08-05 11:50:07PLUMBING PLAN REVIEW
 PERMIT: 09070118
 ADD: 3400 N FLAGLER DR
 CONT: O/B SANDERSON, FREDA
 TEL: (561)655-2012
  
 FL BLD CODE= 2007 FLORIDA BUILDING CODE
 W/ 2009 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 AUGUST 5/2009
 1ST REVIEW
 ACTION: DENIED
  
 1) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER
 MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC
 BUILDING WITH 2009 SUPPLEMENTS.
  
 2) PLEASE PROVIDE A PUNCH LIST OF ITEMS THAT ARE TO BE
 COVERED UNDER THIS PERMIT APPLICATION.
  
 A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A
 RESULT OF THE ADDITIONAL INFORMATION REQUESTED
 ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF
 THIS REVIEW.
  
 JIM WITMER C. B. O.
 COMMERCIAL COMBINATION PLAN REVIEW
 I & 2 FAMILY PLAN REVIW SFP-100
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
 SURVEY:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.

Review Stop Z ZONING
Rev No 1 Status P Date 2009-07-22 Cont ID  
Sent By mcruz Date 2009-07-22 Time 11:38 Rev Time 0.00
Received By mcruz Date 2009-07-21 Time 11:29 Sent To  
Notes
2009-07-22 11:38:34PASSED WITH PROVISO:
 THE LANDSCAPE/IRRIGATION PLANS SHALL BE APPROVED PRIOR
 TO FINAL C.O.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  
 ROUTED BACK R16