Plan Review Details - Permit 09060730
Plan Review Stops For Permit 09060730
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2009-12-10 Cont ID  
Sent By shill Date 2009-12-10 Time 13:41 Rev Time 0.00
Received By shill Date 2009-12-10 Time 13:41 Sent To  
Notes
2009-12-10 13:43:24****PROVISO****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007
 FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 REDLINED PLAN PER CONTRACTOR/OWNER SPECIFICATION:
  
 DOUBLE 2X4 HEADERS OVER THE DOOR AND WINDOW, 24IN OC
 WALL FRAMING SPACING.
  
 DOOR & WINDOWS NOT TO EXCEED 48"
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2009-12-02 Cont ID  
Sent By shill Date 2009-12-02 Time 13:57 Rev Time 0.00
Received By shill Date 2009-12-02 Time 11:59 Sent To  
Notes
2009-12-02 13:57:32****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007
 FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1ST REVIEW FOR STRUCTURAL DETAIL
  
 1. FBC R301.1, ALL PARTS ARE TO BE CONSTRUCTED TO
 SAFELY SUPPORT ALL LOADS. BY WHICH STANDARD IS THIS
 DESIGNED TO? PLANS GIVE A CODE REFERENCE, FBC
 R6023.2(5), WHICH APPEARS TO CONTAIN A TYPO. SEE FBC
 R602.2, 602.3, 301.1.3. THE PRESCRIPTIVE METHODS IN
 R602 ARE FOR WIND SPEEDS OF LESS THAN 100MPH. OTHER
 PRESCRIPTIVE METHODS ARE AVAILABLE, SEE FBC R301.1, OR
 MAY BE ENGINEERED FBC R301.13.
  
 IT IS NOT CLEAR HOW YOU HAVE DETERMINED THAT A SINGLE
 2X4 IS ACCEPTABLE AS A HEADER OVER THE DOOR AND WINDOW,
 AND THAT 24IN OC IS ACCEPTABLE FOR WALL FRAMING
 SPACING.
  
 2. PROVIDE DIMENSIONS FOR THE DOOR AND WINDOWS. THE
 DOOR HEIGHT IS SPECIFIED, BUT NOT THE WIDTH, WINDOWS DO
 NOT HAVE ANY DIMENSIONS.
  
 3. PROVIDE COMPLETE INFORMATION REGARDING THE LUMBER,
 DIMENSION AND GRADE. FBC R301.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2009-09-10 Cont ID  
Sent By shill Date 2009-09-10 Time 11:29 Rev Time 0.00
Received By shill Date 2009-09-10 Time 11:29 Sent To  
Notes
2009-09-10 12:03:32****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007 WITH 2009 SUPPLEMENTS
 FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1. A DETAIL WAS PROVIDED FOR THE INFILL, BUT NOT FOR
 THE DOOR AND WINDOW. PLEASE PROVIDE A DETAIL OF
 PROPOSED CONSTRUCTION. FBC R301
  
 2. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED FOR
 THE DOOR AND WINDOW, FAC9B72. THEY MAY BE AVAILABLE AT
 WWW.FLORIDABUILDING.ORG. THE RESPONSE LETTER STATES
 THAT THIS IS INCLUDED IN ANOTHER PERMIT. THAT PERMIT
 HAS PRODUCT APPROVALS FROM 2007; THE CODE IN EFFECT AT
 THAT TIME IS NO LONGER IN EFFECT AND THE PRODUCT
 APPROVALS PROVIDED AT THAT TIME MAY OR MAY NOT BE CODE
 COMPLIANT AND MUST BE REVIEWED AT THIS TIME. FOR
 INSTALLATION OF A DOOR AND A WINDOW TO BE INCLUDED IN
 THE SCOPE OF WORK FOR THIS PERMIT, PLEASE PROVIDE THE
 DOCUMENTS REQUESTED. A FLORIDA STATE PRODUCT APPROVAL,
 MIAMIDADE NOA, OR LOCAL PRODUCT APPROVAL CAN BE
 SUBMITTED. PLEASE PROVIDE TWO COMPLETE COLLATED SETS OF
 PERMIT DOCUMENTS.
  
 3. N/A.
  
 4. IT APPEARS THAT, BASED ON THE PLAN PROVIDED, YOU ARE
 CUTTING A HOLE IN WHAT WAS ORIGINALLY A BEARING
 EXTERIOR WALL (NEW CLOSET). PROVIDE A STRUCTURAL
 DETAIL.
  
 5. DECLARE WIND DESIGN CRITERIA; WIND ZONE (140MPH
 MIN), AND EXPOSURE CLASSIFICATION.
 THE WIND DESIGN CRITERIA SHOULD BE INCORPORATED INTO
 THE PLAN. ALSO INCLUDE EXPOSURE CLASSIFICATION.
  
 6. PROVIDE A DETAIL FOR THE WALL INFILL.
 A STRUCTURAL DETAIL WAS PROVIDED FOR THE WALL INFILL;
 HOWEVER, IT IS NOT CLEAR HOW THE DETAIL PROPOSED WILL
 MEET DESIGN AND UPLIFT AND OTHER REQUIREMENTS OF FBC
 R301. SOME CONNECTORS DO NOT HAVE F1/F2 RATINGS, OTHERS
 DO NOT HAVE ANY UPLIFT RESISTANCE. PROVIDE CALCULATIONS
 TO SHOW THAT EACH CONNECTOR MEETS THE REQUIREMENTS
 SPECIFIC TO YOUR JOB, AND/OR REVISE CONNECTOR SELECTION
 AS NEEDED. THE DETAIL DOES NOT ALL INFORMATION; IT IS
 RECOMMENDED THAT YOU INCLUDE A SECTION WHICH SHOWS
 INSULATION, VAPOR BARRIER, SHEATHING, SIDING, ETC. OR
 OTHERWISE INCORPORATE THAT INFORMATION INTO THE DETAIL.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-07-20 Cont ID  
Sent By shill Date 2009-07-20 Time 15:08 Rev Time 0.00
Received By shill Date 2009-07-20 Time 15:08 Sent To  
Notes
2009-07-20 15:21:59****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2007 WITH 2009 SUPPLEMENTS
 FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1. PROVIDE A STRUCTURAL DETAIL FOR PROPOSED WORK
 (EXTERIOR WALLS).
  
 2. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED FOR
 THE DOOR AND WINDOW, FAC9B72. THEY MAY BE AVAILABLE AT
 WWW.FLORIDABUILDING.ORG.
  
 3. FOR THE FENCE, PROVIDE EASEMENT CONSENT RELEASES
 FROM ALL POTENTIAL EASEMENT HOLDERS (FPL, COMCAST, GAS
 CO., ETC.).
  
 4. IT APPEARS THAT, BASED ON THE PLAN PROVIDED, YOU ARE
 CUTTING A HOLE IN WHAT WAS ORIGINALLY A BEARING
 EXTERIOR WALL (NEW CLOSET). PROVIDE A STRUCTURAL
 DETAIL.
  
 5. DECLARE WIND DESIGN CRITERIA; WIND ZONE (140MPH
 MIN), AND EXPOSURE CLASSIFICATION.
  
 6. PROVIDE A DETAIL FOR THE WALL INFILL.
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2009-11-18 Cont ID  
Sent By btrobaug Date 2009-11-18 Time 16:20 Rev Time 0.00
Received By btrobaug Date 2009-11-18 Time 16:04 Sent To B
Notes
2009-11-18 16:20:36TO SAMANTHA./WRT

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2009-09-02 Cont ID  
Sent By btrobaug Date 2009-09-02 Time 15:04 Rev Time 0.00
Received By btrobaug Date 2009-09-02 Time 14:56 Sent To B
Notes
2009-09-02 15:04:33 
  
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2007 FLORIDA RESIDENTIAL BUILDING CODE, 2009
 REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND
 FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 1} 106.1 SUBMITTAL DOCUMENTS. CONSTRUCTION DOCUMENTS,
 SPECIAL INSPECTION AND STRUCTURAL OBSERVATION PROGRAMS,
 AND OTHER DATA SHALL BE SUBMITTED IN TWO OR MORE SETS
 WITH EACH APPLICATION FOR A PERMIT.
  
 2} R313.2.1 ALTERATIONS, REPAIRS AND ADDITIONS.
 WHEN INTERIOR ALTERATIONS, REPAIRS OR ADDITIONS
 REQUIRING A PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING
 ROOMS ARE ADDED OR CREATED IN EXISTING DWELLINGS, THE
 INDIVIDUAL DWELLING UNIT SHALL BE PROVIDED WITH SMOKE
 ALARMS LOCATED AS REQUIRED FOR NEW DWELLINGS; THE SMOKE
 ALARMS SHALL BE INTERCONNECTED AND HARD WIRED. INDICATE
 INTERCONNECTION AND LOCATE THE ALARMS ON THE PLAN.
  
 NOTE: COMMENT #2 CAN BE ADDED AS A PROVISO IT THE
 SECOND SET OF PLANS ARE BROUGT IN. THE ELECTRICAL
 REVIEW COULD BE PASSED.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2009-07-14 Cont ID  
Sent By btrobaug Date 2009-07-14 Time 12:27 Rev Time 0.00
Received By btrobaug Date 2009-07-14 Time 12:17 Sent To B
Notes
2009-07-14 12:26:51 
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2007 FLORIDA RESIDENTIAL BUILDING CODE, 2009
 REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND
 FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 1} THERE IS AN ELECTRICAL PERMIT APPLIED FOR, BUT NO
 ELECTRICAL PLANS WERE SUBMITTED. SUBMIT PLANS
 INDICATING THE SCOPE OF WORK. 106.1 FBC AS AMENDED.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2009-11-04 Cont ID  
Sent By lmartine Date 2009-11-03 Time 09:17 Rev Time 0.00
Received By lmartine Date 2009-11-03 Time 09:17 Sent To  
Notes
2009-11-04 09:18:47GAVE TO BILLIE T.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-09-02 Cont ID  
Sent By kstevens Date 2009-09-02 Time 14:33 Rev Time 0.00
Received By kstevens Date 2009-09-02 Time 14:33 Sent To  
Notes
2009-09-02 14:34:18SENT TO BTROBAUGH.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-07-20 Cont ID  
Sent By shill Date 2009-07-20 Time 15:22 Rev Time 0.00
Received By shill Date 2009-07-01 Time 08:12 Sent To  
Notes
2009-07-01 08:12:58SENT TO ZONING

Review Stop Z ZONING
Rev No 1 Status N Date 2009-07-06 Cont ID  
Sent By mcruz Date 2009-07-06 Time 08:54 Rev Time 0.00
Received By mcruz Date 2009-07-06 Time 08:54 Sent To  
Notes
2009-07-06 08:54:33*ZONING REVIEW NOT REQUIRED: INTERIOR WORK ONLY AND THE
 VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE
 IMPROVEMENT VALUE.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  
 PLACED IN MISC #3