Plan Review Details - Permit 09060583
Plan Review Stops For Permit 09060583
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-08-11 Cont ID  
Sent By jwitmer Date 2009-08-11 Time 17:29 Rev Time 0.50
Received By jwitmer Date 2009-08-11 Time 17:20 Sent To  
Notes
2009-08-11 17:21:42REVISION:A
 SHEETS A1& A2

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2009-07-01 Cont ID  
Sent By jwitmer Date 2009-07-01 Time 14:15 Rev Time 0.55
Received By jwitmer Date 2009-07-01 Time 14:14 Sent To  
Notes
2009-07-01 14:16:38BUILDING PROVISO:
 PROVIDE INFORMATION ON STEAM SHOWER/ SHOWER GLAZING,
 BUILDING PROVISO: 2406.3 HAZARDOUS LOCATIONS. THE
 FOLLOWING SHALL BE CONSIDERED SPECIFIC HAZARDOUS
 LOCATIONS REQUIRING SAFETY GLAZING MATERIALS:
 ( 5) GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS,
 WHIRLPOOLS, SAUNAS, STEAM ROOMS, BATHTUBS AND SHOWERS.
 GLAZING IN ANY PORTION OF A BUILDING WALL ENCLOSING
 THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE
 GLAZING IS LESS THAN 60 INCHES (1524 MM) ABOVE A
 STANDING SURFACE.
 .

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2009-08-06 Cont ID  
Sent By btrobaug Date 2009-08-06 Time 12:32 Rev Time 0.00
Received By btrobaug Date 2009-08-06 Time 12:32 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2009-07-04 Cont ID  
Sent By dpalmer Date 2009-07-04 Time 15:47 Rev Time 0.00
Received By dpalmer Date 2009-07-04 Time 15:47 Sent To  
Notes
2009-07-04 15:50:07REDLINED PLANS.
  
 VIF SMOKE ALARMS MEETING NFPA-72
 VIF LISTING OF STEAM GENERATOR PER A NRTL. 110.3

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2009-07-07 Cont ID  
Sent By mawillia Date 2009-07-07 Time 11:12 Rev Time 0.00
Received By mawillia Date 2009-07-07 Time 11:03 Sent To  
Notes
2009-07-07 11:09:05*(****APPROVED*****
  
  
 PLAN SHEETS A-1 AND A-2 WERE STAMPED, INITIALED, AND
 DATED.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2009-08-18 Cont ID  
Sent By lmartine Date 2009-08-18 Time 10:49 Rev Time 0.00
Received By lmartine Date 2009-08-18 Time 10:49 Sent To  
Notes
2009-08-18 10:53:44GAVE TO KENNY

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-08-06 Cont ID  
Sent By lmartine Date 2009-08-06 Time 09:49 Rev Time 0.00
Received By lmartine Date 2009-08-06 Time 09:49 Sent To  
Notes
2009-08-06 09:50:07B-8

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-07-09 Cont ID  
Sent By kstevens Date 2009-07-09 Time 13:37 Rev Time 0.00
Received By kstevens Date 2009-06-24 Time 13:50 Sent To  
Notes
2009-06-30 10:43:43MOVED TO B21 ON 6/30/09 (WAS PREVIOUSLY IN C5 DUE TO
 LACK OF SLOTS ON BOB)
  
2009-06-24 13:51:53C5
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2009-08-19 Cont ID  
Sent By kstevens Date 2009-08-19 Time 12:18 Rev Time 0.00
Received By kstevens Date 2009-08-19 Time 12:18 Sent To  
Notes
2009-08-19 12:19:19REVISION OK -- SHT P-1
  
  
  
  
  
  
  
  
 PASSED/PROVISO:
  
 THE MANUF. SPECIFICATION/INSTALLATION SHEETS FOR THE
 STEAM GENERATOR ARE REQUIRED TO BE ON THE JOB FOR ROUGH
 INSPECTION.
  
  
  
 .

Review Stop P PLUMBING
Rev No 2 Status F Date 2009-08-11 Cont ID  
Sent By kstevens Date 2009-08-11 Time 12:45 Rev Time 0.00
Received By kstevens Date 2009-08-11 Time 12:45 Sent To  
Notes
2009-08-11 12:50:52DENIED
 REFERENCE:
 FBC-2007 CHAPTER 1
  
 1. SHT P-1 INDICATES RECONNECTING EXISTING SANITARY &
 WATER TO NEW LAV AS SHOWN ON SHT A-2 DETAIL #1, BUT IS
 INDICATED AS "DELETE SINK" IN HAND WRITTEN WORDS. HAND
 WRITTEN CHANGES TO SIGNED, SEALED & DATED PLANS OF A
 DESIGN PROFESSIONAL IS NOT ACCEPTABLE. SECTION 106.1.3.
 ALSO ALL SHEETS SHALL CORRELATE. IF THE SINK IS DELETED
 ON THE PLUMBING FLOOR PLAN, THEN IT SHALL BE DELETED ON
 THE ARCHITECTURAL SHEETS AS WELL.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2009-07-09 Cont ID  
Sent By kstevens Date 2009-07-09 Time 13:35 Rev Time 0.00
Received By kstevens Date 2009-07-09 Time 13:35 Sent To  
Notes
2009-07-09 13:37:14 
  
 PASSED/PROVISO:
  
 THE MANUF. SPECIFICATION/INSTALLATION SHEETS FOR THE
 STEAM GENERATOR ARE REQUIRED TO BE ON THE JOB FOR ROUGH
 INSPECTION.
  
  
  
 .

Review Stop Z ZONING
Rev No 1 Status N Date 2009-06-25 Cont ID  
Sent By eschneid Date 2009-06-25 Time 15:49 Rev Time 0.25
Received By eschneid Date 2009-06-25 Time 15:40 Sent To  
Notes
2009-06-25 15:49:53INTERIOR ONLY LESS THAN 50% OF BUILIDNG VALUE.