Plan Review Details - Permit 09060561
Plan Review Stops For Permit 09060561
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-07-20 Cont ID  
Sent By jwitmer Date 2009-07-20 Time 10:54 Rev Time 0.66
Received By jwitmer Date 2009-07-20 Time 10:54 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-06-26 Cont ID  
Sent By jwitmer Date 2009-06-26 Time 16:29 Rev Time 0.44
Received By jwitmer Date 2009-06-26 Time 16:29 Sent To PC
Notes
2009-06-26 16:38:13BUILDING PLAN REVIEW
 PERMIT: 09060561
 ADD: 4500 # N301
 CONT: HBR DEVELOPERS
 TEL: (561)371-8546
  
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2007 FBC SUPPLEMENTS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW
 ACTION: DENIED
  
 1) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER
 MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC
 BUILDING WITH 2009 SUPPLEMENTS.
  
  
 2) MISSING WIND DESIGN CRITERIA, HEIGHT OF BUILDING,
 WINDOW SIZES, IF OPENINGS ARE IN A INTERIOR ZONE (ZONE
 4) OR END ZONE (ZONE 5).
 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL-FORCE-RESISTING SYSTEM OF THE
 BUILDING:
 1. BASIC WIND SPEED (3-SECOND GUST), MILES PER HOUR
 (KM/HR).
  
 2. WIND IMPORTANCE FACTOR, I W , AND BUILDING
 CLASSIFICATION FROM TABLE 1604.5 OR TABLE 6-1, ASCE 7
 AND BUILDING CLASSIFICATION IN TABLE 1-1, ASCE 7.
  
 3. WIND EXPOSURE, IF MORE THAN ONE WIND EXPOSURE IS
 UTILIZED, THE WIND EXPOSURE AND APPLICABLE WIND
 DIRECTION SHALL BE INDICATED.
  
 4. THE APPLICABLE ENCLOSURE CLASSIFICATIONS AND, IF
 DESIGNING WITH ASCE 7, INTERNAL PRESSURE COEFFICIENT.
  
 5. COMPONENTS AND CLADDING. THE DESIGN WIND PRESSURES
 IN TERMS OF PSF (KN/M 2 ) TO BE USED FOR THE SELECTION
 OF EXTERIOR COMPONENTS AND CLADDING MATERIALS NOT
 SPECIFICALLY DESIGNED BY THE REGISTERED DESIGN
 PROFESSIONAL.
  
 3) SCOPE OF WORK, FOR WINDOWS AND SHUTTERS, PLEASE
 IDENTIFY IF THE WINDOWS ARE BEING REPAIRED, OR
 REPLACED, PLEASE DO THE SAME FOR THE SHUTTERS. NO
 PRODUCT APPROVALS FOR STORM SHUTTERS WAS SUBMITTED.
 2007 FBC 106.1.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY
 TO INDICATE THE LOCATION, NATURE & EXTENT OF THE WORK
 PROPOSED & SHOW IN DETAIL THAT IT WILL CONFORM TO THE
 PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES,
 AND RULES AND REGULATIONS AS DETERMINED BY THE BUILDING
 OFFICIAL.
  
 JIM WITMER C. B. O.
 BUILDING PLAN REVIEW II
  
 TEL: (561)805-6715
 FAX: (561)805-6731
 E-MAIL: [email protected]
 SURVEY:
 WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES
  
 PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS
 LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS
 REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO
 THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE
 THEREFORE SUBJECT TO PUBLIC DISCLOSURE.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2009-07-17 Cont ID  
Sent By btrobaug Date 2009-07-17 Time 18:15 Rev Time 0.00
Received By btrobaug Date 2009-07-17 Time 18:15 Sent To B
Notes
2009-07-17 18:16:45TO JIM'S DESK./WRT.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2009-06-24 Cont ID  
Sent By btrobaug Date 2009-06-24 Time 16:50 Rev Time 0.00
Received By btrobaug Date 2009-06-24 Time 16:46 Sent To P
Notes
2009-06-24 16:50:26 
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2007 FLORIDA RESIDENTIAL BUILDING CODE, 2009
 REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND
 FOUND NONCOMPLIANT WITH THE FOLLOWING:
  
 1} PLANS INDICATING THE SCOPE OF WORK MUST BE SUBMITTED
 WITH THE APPLICATION. 106.1 FBC AS AMENDED. TWO SETS.
 PLEASE SUBMIT A FLOOR PLAN AND INDICATING THE LOCATION
 OF ALL EQUIPMENT AND DEVICES BEING INSTALLED UNDER THE
 SCOPE OF THIS APPLICATION.106.1.1 FBC.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-07-15 Cont ID  
Sent By shill Date 2009-07-15 Time 09:39 Rev Time 0.00
Received By shill Date 2009-07-15 Time 09:39 Sent To  
Notes
2009-07-15 09:39:47TO BT DESK

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-06-26 Cont ID  
Sent By jwitmer Date 2009-06-26 Time 16:38 Rev Time 0.00
Received By jwitmer Date 2009-06-24 Time 14:25 Sent To  
Notes
2009-06-24 14:25:58TO ELECTRIC
  

Review Stop P PLUMBING
Rev No 1 Status N Date 2009-06-25 Cont ID  
Sent By kstevens Date 2009-06-25 Time 09:39 Rev Time  
Received By kstevens Date   Time   Sent To B
Notes
2009-06-25 09:41:50NO PLUMBING PLANS REQUIRED FOR WORK INDICATED.