Plan Review Details - Permit 09060555
Plan Review Stops For Permit 09060555
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-07-28 Cont ID  
Sent By jgomez Date 2009-07-28 Time 14:37 Rev Time 0.00
Received By jgomez Date 2009-07-28 Time 14:36 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-07-15 Cont ID  
Sent By jgomez Date 2009-07-15 Time 10:25 Rev Time 0.00
Received By jgomez Date 2009-07-15 Time 10:25 Sent To  
Notes
2009-07-15 10:53:38RESIDENTIAL (R3)) ROOF, BUILDING REVIEW CHECKLIST.
 2007 FL. RESIDENTIAL CODE WITH 2009 REVISIONS.
  
 ***NOTE: COMMENTS FOR ROOF PERMIT ONLY BECAUSE OF ROOF
 LEAKS. REVIEW OF PROPOSED ADDITION NOT DONE AT THIS
 TIME.
  
 1- CLEARLY INDICATE ON PRODUCT APPROVAL SUBMITTED WHICH
 FLAT ROOF APPROVED ASSEMBLY AND BASE SHEET FASTENING
 OPTION IS GOING TO BE USED TO VERIFY COMPLIANCE WITH
 THE DESIGN PRESSURES OF SEC. R301 OF 2007 FLORIDA
 RESIDENTIAL CODE.
  
 2- NOA 07-0228.06 SUBMITTED HAS A HANDWRITTEN NOTE
 STATING PAGE 16. PAGE 16 CORRESPONDS TO AN INSULATED
 FLAT ROOF SYSTEM AND IS LIMITED BY GENERAL LIMITATION
 #9. THIS SYSTEM IS GOOD FOR A MAXIMUM DESIGN PRESSURE
 OF -45PSF. GENERAL LIMITATION #9 (SEE SHEET 26 OF 26)
 DOESN'T ALLOW ANY NAIL ENHANCING. THIS ASSEMBLY CAN NOT
 BE USED IN THIS BUILDING BECAUSE IT DOESN'T MEET THE
 DESIGN PRESSURES. THIS BUILDING IS LOCATED ON EXPOSURE
 "C" AND THE DESIGN PRESSURES FOR PERIMETER AND CORNER
 AREAS ARE HIGHER THAN THOSE SPECIFIED ON THE SELECTED
 SYSTEM.
  
 3- SELECT ANOTHER SYSTEM WITH GENERAL LIMITATION #7 AND
 PROVIDE SIGNED AND SEALED RAS 117 CALCULATIONS FOR NAIL
 ENHANCING AT PERIMETER AND CORNER AREAS AS REQUIRED BY
 GENERAL LIMITATION #7 ON LAST PAGE OF NOA SUBMITTED.
 NOTE: DESIGN PROFESSIONAL TO TAKE IN CONSIDERATION THAT
 THIS BUILDING IS LOCATED ON EXPOSURE "C" WHEN PROVIDING
 THE RAS 117 CALCULATIONS.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-07-15 Cont ID  
Sent By lmartine Date 2009-07-15 Time 15:25 Rev Time 0.00
Received By lmartine Date 2009-06-24 Time 09:15 Sent To  
Notes
2009-06-24 09:16:02SENT TO ZONING BOX.

Review Stop Z ZONING
Rev No 3 Status P Date 2009-08-10 Cont ID  
Sent By mcruz Date 2009-08-10 Time 14:31 Rev Time 0.00
Received By mcruz Date 2009-08-10 Time 14:26 Sent To B
Notes
2009-08-10 14:32:10REPLACING EXISTING...NO ADDITIONAL SQUARE FOOTAGE BEING
 ADDED.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  
 ROUTED TO LM

Review Stop Z ZONING
Rev No 2 Status N Date 2009-07-28 Cont ID  
Sent By mcruz Date 2009-07-28 Time 14:16 Rev Time 0.00
Received By mcruz Date 2009-07-28 Time 14:14 Sent To B
Notes
2009-07-28 14:16:43**ZONING REVIEW NOT REQUIRED - PERMIT FOR ROOF REPAIR
 ONLY, NOT ADDITION.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 2009-07-05 Cont ID  
Sent By mcruz Date 2009-07-05 Time 13:23 Rev Time 0.00
Received By mcruz Date 2009-07-05 Time 13:19 Sent To B
Notes
2009-07-05 13:23:21PLANNING AND ZONING DEPT: ***ZONING FAILED***
  
 1. PLEASE PROVIDE ALL RESPONSES IN WRITING.
  
 2. THE PERMIT DESCRIPTION INDICATES THE PROPOSED WORK
 IS TO REPLACE THE EXISTING FLAT ROOF AND ADD TRUSSES TO
 EXISTING STRUCTURE; HOWEVER, THE PLANS INDICATE AN
 ADDITION TO THE STRUCTURE. PLEASE CLARIFY.
  
 3. IF THE THERE IS AN ADDITIONA BEING PROPOSED, PLEASE
 REVISE THE PERMIT DESCRIPTION AND PROVIDE TWO (2)
 COPIES OF A CURRENT SURVEY, WHICH INCLUDES THE
 PROPERTY'S ADDRESS AND LEGAL DESCRIPTION.
  
 INDICATE ON THE SURVEY THE SETBACK DIMENSIONS FROM THE
 PROPOSED ADDITION TO ALL ADJACENT PROPERTY LINES.
 PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND LAND
 DEVELOPMENT REGULATIONS (ZLDR), SECTION 94-72(A)(2):
 SINGLE-FAMILY LOW DENSITY (SF7) RESIDENTIAL DISTRICT -
 MINIMUM SETBACKS FOR PRINCIPAL BUILDING ARE AS FOLLOWS:
  
 A. FRONT: 25 FEET;
  
 B. CORNER: 12.5 FEET;
  
 C. REAR: 15 FEET OR TEN PERCENT OF LOT DEPTH, WHICHEVER
 IS LESS;
  
 D. SIDE: FIVE FEET MINIMUM, 15 FEET TOTAL.
  
  
 NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY
 GENERATE ADDITIONAL COMMENTS.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  
 PLACED IN MISC BOX #2