Plan Review Details - Permit 09060499
Plan Review Stops For Permit 09060499
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-07-16 Cont ID  
Sent By shill Date 2009-07-16 Time 18:21 Rev Time 0.00
Received By shill Date 2009-07-16 Time 18:17 Sent To Z
Notes
2009-07-16 18:35:02***PROVISO***
 ***THIS PERMIT IS ISSUED AT CONTRACTOR'S RISK***
 INSTALLATION TO COMPLY WITH THE FOLLOWING:
  
 1. FBC424.1.3.1.2, POOL WET DECKS SHALL B EUNIFORMLY
 SLOPED AT A MINIMUM OF 2 PERCENT TO A MAXIMUM OF 4
 PERCENT AWAY FROM THE POOL OR TO DECK DRAINS TO PREVENT
 STANDING WATER. WHEN A CURB IS PROVIDED, THE DECK SHALL
 NOT BE MORE THAN 10 INCHES BELOW THE TOP OF THE CURB.
  
 2. THIS INSTALLATION SHALL COMPLY WITH FBC CHAPTER 11,
 ACCESSIBILITY. ELEVATION AT ALL DOORS TO MEET
 ACCESSIBILITY REQUIREMENTS FBC 11-4.5.2.
  
 3. THIS PERMIT DOES NOT INCLUDE ELECTRIC OR PLUMBING
 WORK. ANY ELECTRIC/PLUMBING (OUTLETS, DRAINS) ARE TO BE
 UNDER SEPARATE PERMIT.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-07-14 Cont ID  
Sent By efabian Date 2009-07-14 Time 16:11 Rev Time 0.00
Received By   Date 2009-07-14 Time 16:12 Sent To ENG
Notes
2009-06-25 15:07:43SPOKE WITH CONTRACTOR TODAY, 6-25-09. DISCUSSED NEED
 FOR SITE PLAN OF PROPOSED COURTYARD/POOL AREA
 REPLACEMENT. PLEASE LOCATE PROPOSED DRAIN
 WORK/REPLACEMENT, FLOOR ELECTRICAL BOX
 LOCATIONS/CHANGES? PLEASE DETAIL A TYPICAL PAVER TO
 DOOR THRESHOLD ELEVATION.

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2009-07-14 Cont ID  
Sent By efabian Date 2009-07-14 Time 16:09 Rev Time 0.00
Received By efabian Date 2009-07-14 Time 16:09 Sent To B
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2009-07-14 Cont ID  
Sent By efabian Date 2009-07-06 Time   Rev Time 0.00
Received By MGONZALE Date 2009-07-08 Time 16:15 Sent To  
Notes
2009-07-06 12:05:26SPOKE WITH SITE REPRESENTATIVE 07-03-09 AND ON 07/06/09
  
 DANIEL WESENESKY AT 954-588-4720
 CELL 561-929-5227
 FAX # 954-482-0370
  
 NOT SURE OF HOW MUCH OF THE WORK TRIGGERS A DRAINAGE
 REVIEW HOWEVER WE CAN DETERMINE UPON SUBMITTAL OF A
 WRITTEN IMPACT SUMMARY FROM AN ENGINEER (CIVIL
 ENGINEER, P.E.). THIS INFORMATION ALONG WITH PERVIOUS
 AND IMPERVIOUS AREA CALCULATIONS WOULD NEED TO BE ADDED
 SO THAT THE STORMWATER ACCOUNT CAN BE UPDATED IF
 SIGNIFICANT CHANGE WILL BE MADE.
  
 THANK YOU!
  
 MANNY GONZALEZ
 PROJECT COORDINATOR
 ENGINEERING SERVICES DEPT.
 (561) 494-1085
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-07-10 Cont ID  
Sent By shill Date 2009-07-10 Time 16:24 Rev Time 0.00
Received By shill Date 2009-07-10 Time 16:24 Sent To  
Notes
2009-07-10 16:24:20TO ZONING

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-07-10 Cont ID  
Sent By shill Date 2009-06-25 Time 16:23 Rev Time 0.00
Received By shill Date 2009-07-10 Time 16:22 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2009-07-20 Cont ID  
Sent By eschneid Date 2009-07-20 Time 13:22 Rev Time 0.25
Received By eschneid Date 2009-07-20 Time 13:21 Sent To B
Notes
2009-07-20 13:22:30PASSED
  
 NO LANDSCAPE MAY BE REMOVED AS PART OF THIS PERMIT.