| Plan Review Stops For Permit 09060429 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2009-09-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-09-24 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-09-24 |
Time |
15:58 |
Sent To |
|
|
| Notes |
| 2009-09-24 16:02:00 | SUBMIT TWO CLARIFICATION LETTERS FROM THE ENGINEER FOR | | | THE MINIMUM EMBED DEPTH OF THE TAPCONS IN THE DOOR | | | ANCHOR DETAIL ON SHEET 1.3. THE NUMBER IS ILLEGIBLE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2009-08-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-08-10 |
Time |
15:29 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-08-10 |
Time |
15:29 |
Sent To |
|
|
| Notes |
| 2009-08-10 15:41:26 | 2007 FBC W/2009 REVISIONS | | | LEVEL 1 ALTERATION | | | | | | DENIED BY BUILDING | | | | | | 1) SUBMIT TWO COPIES OF PLANS DETAILING THE WORK THAT | | | WILL BE DONE TO THE PORCH. THE DETAIL THAT WAS | | | SUBMITTED IS NOT ADEQUATE. IT ONLY STATES REMOVE AND | | | REPLACE COLUMNS. SPECIFY THE SIZE, TYPE AND NUMBER OF | | | COLUMNS BEING REPLACED. SPECIFY HOW THE NEW COLUMNS | | | WILL BE ANCHORED AT THE TOP AND BOTTOM (SPECIFY | | | CONNECTORS) IN ORDER TO PROVIDE A CONTINUOUS LOAD PATH | | | TO RESIST WIND-LOADS. PROVIDE DRAWINGS SHOWING THE | | | DIMENSIONS OF THE PORCH, SPANS, ETC. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2009-07-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-07-13 |
Time |
08:06 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-07-13 |
Time |
08:05 |
Sent To |
|
|
| Notes |
| 2009-07-13 08:43:23 | 2007 FBC | | | RENOVATION | | | | | | DENIED BY BUILDING | | | | | | 1) SUBMIT TWO COPIES OF A PLANS, SHOWING COMPLIANCE | | | WITH THE 2007 FBC, FOR THE PORCH THAT WILL BE BUILT TO | | | REPLACE THE EXISTING ONE THAT WILL BE DEMOLISHED. | | | SPECIFY DIMENSIONS, | | | | | | 2) SPECIFY WINDOW OPENING SIZES, CONFIGURATIONS, NUMBER | | | OF ANCHORS, SILL TYPE, GLASS TYPE AND DESIGN PRESSURES | | | FOR THE HORIZONTAL SLIDING WINDOWS THAT WILL BE | | | INSTALLED. CIRCLE THE APPROPRIATE ITEMS ON THE TABLES | | | GIVEN IN THE NOA. | | | | | | 3) SHOW THAT THE SLEEPING ROOM WINDOWS WILL COMPLY WITH | | | FBC R310 AND SECTION 604 OF THE EXISTING BUILDING CODE | | | FOR EMERGENCY ESCAPE AND RESCUE. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2009-10-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-10-08 |
Time |
17:56 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-10-08 |
Time |
17:56 |
Sent To |
PC |
|
| Notes |
| 2009-10-08 17:56:15 | | | | | | | ** PROVISO ** | | | | | | 1) NOTE: AS NOTED ON PREVIOUS REVIEW STORAGE TYPE OF | | | WATER HEATER LOADS SHALL BE FIGURED AT 125%. LOAD | | | CALCULATIONS SHOW 125% HOWEVER IT WAS NOT FIGURED INTO | | | CALCULATIONS AT THAT RATE. | | | 4500VA @ 125% IS 5625VA, | | | | | | 2) NOTE: PANEL SCHEDULE SHALL BE SPECIFIC. THE USE OF | | | GENERAL LIGHTING/GENERAL RECEPTACLES IS NOT ACCEPTABLE. | | | PLEASE SEE NEC 2005 408.4 AND COMMENTARY IN NEC | | | HANDBOOK. | | | | | | ** PLEASE REVISE THE ABOVE ITEMS BEFORE FINAL. IF THERE | | | ARE OTHER REVISIONS THEN THEY MUST BE REVISED BEFORE | | | ROUGH. | | | | | | **IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2009-09-28 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-09-28 |
Time |
09:24 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-09-28 |
Time |
09:24 |
Sent To |
|
|
| Notes |
| 2009-09-28 09:24:48 | | | | ** DENIED ** | | | | | | ** COMPLETE NEW PLANS SUBMITTED WHICH HAVE NOT BEEN | | | PREVIOUSLY SUBMITTED OR REVIEWED. | | | | | | 1) NOTE: PLANS CONTAIN A NOTE WHICH STATES ALL | | | ELECTRICAL IS TO BE DONE UNDER THE 2008 NEC. HOWEVER | | | ALL PERMIT APPLICATIONS SUBMITTED BEFORE OCTOBER 1ST, | | | 2009 IS UNDER THE 2005 NEC. | | | | | | 2) NOTE: PLEASE SEE FBC R313.1, 313.2, 313.2.1 FOR | | | SMOKE ALARMS WHICH ARE REQUIRED TO BE BROUGHT UP TO | | | CURRENT CODE. PLEASE SEE NFPA-72 11.5.1 AND 11.8.3 FOR | | | REQUIRED LOCATIONS. | | | PLANS ARE MISSING DEVICES. | | | PLEASE BE SURE TO SEE 11.8.3 AS ALL SMOKE ALARMS WITHIN | | | 20FT OF COOKING APPLIANCES SHALL MEET SPECIFIC | | | REQUIREMENTS. ( OUTSIDE MASTER BEDROOM) | | | | | | 3) NOTE: PLANS/RISER INDICATES A 150AMP SERVICE YET THE | | | FEEDERS FROM THE MAIN TO THE PANEL ARE TOO SMALL. | | | PLEASE SEE 310.16,310.15B6 AS #2 IS NOT RATED FOR | | | 150AMPS. | | | | | | 4) NOTE: PLANS INDICATE ONE A/C SYSTEM WITH 60AMP OVER | | | CURRENT PROTECTION. HOWEVER THE MECHANICAL PLANS | | | INDICATE A SYSTEM WITH 8KW HEAT. THIS 60AMP OCP IS TOO | | | HIGH. 422.13E(3) | | | ** ELECTRICAL PLANS INDICATE 10KW FOR AHU. PLEASE | | | CORRELATE BOTH THE ELECTRICAL AND MECHANICAL PLANS. | | | | | | 5) NOTE: PLANS ARE MISSING THE REQUIRED SWITCH AND | | | LIGHTING OUTLET AT FRONT DOOR ENTRANCE/EXIT. | | | 210.70 | | | | | | 6) NOTE: PLANS ARE MISSING DISCONNECTS FOR BOTH THE | | | CONDENSING UNIT AND AIR HANDLING UNIT PER 440.11, | | | 440.12. | | | | | | PLEASE BE SURE TO SEE 110.26 FOR CLEARANCES. | | | THE SYMBOL SHOWN ON PLANS IS FOR A 220V OUTLET ONLY. | | | | | | 7) NOTE: PLEASE SEE PLANS AS THE DISCONNECT SHOWN ON | | | RISER IS NOT SHOWN ON PLANS. PLEASE SEE 110.26 FOR | | | LOCATION. | | | PANEL SCHEDULE ALSO CONTAINS A NOTE WHICH STATES THE | | | PANEL ALREADY EXISTS, YET THE PLANS STATE THE PANEL AND | | | THE MAIN SERVICE IS NEW. | | | WHICH IS ACCURATE? | | | | | | | | | 8) NOTE: PLEASE SEE 210.52B1 AS ALL CIRCUITS FOR DINING | | | ROOM RECEPTACLES SHALL BE 20AMP AND #12. PANEL SCHEDULE | | | DOES NOT DELINEATE BETWEEN LIGHTS OR RECEPTACLES. PANEL | | | SCHEDULE DOES STATE AFCI PROTECTION WHICH IS NOT | | | REQUIRED HOWEVER MAY BE INSTALLED. | | | PLEASE SEE 210.52B1, 210.11C1 AND 220.53 AS ALL | | | ADDITIONAL DEDICATED CIRCUITS ABOVE THE TWO MINIMUM | | | SMALL APPLIANCE CIRCUITS SHALL BE FIGURED AT 1500VA FOR | | | EACH. LOAD CALCULATIONS ONLY INDICATE TWO SMALL | | | APPLIANCES FOR LOADS. | | | | | | 9) NOTE: AS NOTED ABOVE IN COMMENTS #8, SEE 210.52B1, | | | 210.11C1 AND 220.53 FOR ALL SMALL APPLIANCE LOADS AND | | | ANY DEDICATED DINING ROOM RECEPTACLE CIRCUITS. THE | | | PANEL SCHEDULE INDICATES 3-SMALL APPLIANCE CIRCUITS | | | BEFORE ADDING ANY DINING ROOMS. | | | | | | 10) NOTE: PLEASE SEE 422.13 AS STORAGE TYPE WATER | | | HEATERS ARE CONSIDERED CONTINUOUS LOADS. SEE NEC | | | COMMENTARY AS THE LAST SENTENCE STATES WHEN SIZING FOR | | | SERVICE AND FEEDERS ALSO. THIS MEANS THE WATER HEATER | | | 4500VA SHALL BE FIGURED AT 125% INTO LOAD CALCULATIONS. | | | | | | 11) NOTE: PLEASE INDICATE AIC RATING FOR MAIN AND PANEL | | | PER 110.9. | | | | | | | | | **IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2009-08-04 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-08-04 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-08-04 |
Time |
15:16 |
Sent To |
|
|
| Notes |
| 2009-08-04 15:45:26 | | | | | | | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2007 FLORIDA RESIDENTIAL BUILDING CODE, 2009 | | | REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND | | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | SAME COMMENTS AS THE PREVIOUS REVIEW, NO ELECTRICAL | | | PLANS HAVE BEN SUBMITTED. | | | PLEASE NOTE AN ELECTRICAL PERMIT IS REQUIRED FOR THE | | | SCOPE OF WORK PURPOSED. 105.1 FBC AS AMENDED. | | | | | | 1} PLEASE SUBMIT A FLOOR PLAN AND INDICATING THE | | | LOCATION OF ALL EQUIPMENT AND DEVICES BEING INSTALLED | | | UNDER THE SCOPE OF THIS APPLICATION.106.1.1 FBC. | | | | | | 2} SMOKE ALARMS MUST BE INSTALLED TO COMPLY WITH R313.2 | | | RESIDENTIAL FLORIDA BUILDING CODE.INDICATE LOCATIONS ON | | | THE ELECTRICAL PLAN. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2009-07-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-07-07 |
Time |
12:05 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-07-07 |
Time |
12:04 |
Sent To |
|
|
| Notes |
| 2009-07-07 12:05:00 | | | | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2007 FLORIDA RESIDENTIAL BUILDING CODE, 2009 | | | REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND | | | FOUND NONCOMPLIANT WITH THE FOLLOWING: | | | | | | PLEASE NOTE AN ELECTRICAL PERMIT IS REQUIRED FOR THE | | | SCOPE OF WORK PURPOSED. 105.1 FBC AS AMENDED. | | | | | | 1} PLEASE SUBMIT A FLOOR PLAN AND INDICATING THE | | | LOCATION OF ALL EQUIPMENT AND DEVICES BEING INSTALLED | | | UNDER THE SCOPE OF THIS APPLICATION.106.1.1 FBC. | | | | | | 2} SMOKE ALARMS MUST BE INSTALLED TO COMPLY WITH R313.2 | | | RESIDENTIAL FLORIDA BUILDING CODE.INDICATE LOCATIONS ON | | | THE ELECTRICAL PLAN. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2009-10-01 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-10-01 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-10-01 |
Time |
16:24 |
Sent To |
|
|
| Notes |
| 2009-10-07 15:07:48 | RESUB SUBMITTED ON 10/1 ROUTED TO DP DESK | | | | | 2009-10-01 16:24:19 | IN ZONING |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2009-09-15 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2009-09-09 |
Time |
18:23 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2009-09-09 |
Time |
18:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2009-07-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-07-23 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-07-23 |
Time |
16:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2009-07-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-07-13 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-06-18 |
Time |
10:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
3 |
Status |
P |
Date |
2009-09-14 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-09-14 |
Time |
11:52 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-09-14 |
Time |
11:52 |
Sent To |
|
|
| Notes |
| 2009-09-14 11:53:31 | ***LANDSCAPE REVIEW PASSED PER ANGELLA*** | | | |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
F |
Date |
2009-08-03 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-08-03 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-08-03 |
Time |
09:28 |
Sent To |
|
|
| Notes |
| 2009-08-03 10:49:23 | ***LANDSCAPE REVIEW FAILED*** | | | | | | 1. COMMENTS MADE ON 7/2 HAVE NOT BEEN ADDRESSED. | | | | | | 2. THE LOCATION OF ALL PLANT MATERIAL, NEW AND | | | EXISTING, SHALL BE IDENTIFIED ON THE PLAN AND A PLANT | | | LIST WITH THE PLANT NAMES, QUANTITY, SIZE AND SPACING | | | SHALL BE PART OF THE PLAN. PROPOSED PLANT MATIERIAL | | | SHALL BE SUITABLE FOR THIS ZONE. XERISCAPE POINTS SHALL | | | BE DETERMINED BY USING THE XERISCAPE DESIGN OPTIONS | | | FOUND IN SECTION 94-442 (G) OF THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS. | | | | | | 3. THE LANDSCAPE PLAN SHALL CONTAIN EACH OF THE | | | ELEMENTS IDENTIFIED IN SECTION 94-448 (D). THE PLAN | | | SHALL IDENTIFY THE ADDRESS AND SHOW THE STREET AND | | | RIGHT-OF-WAY. | | | | | | 4. THE LANDSCAPE CALCULATIONS PROVIDED WERE NOT | | | COMPLETE. PLEASE INDICATE HOW THE OPEN SPACE SQUARE | | | FOOTAGE WAS DETERMINED AND AND HOW MANY TREES AND | | | PLANTS WERE PROPOSED. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462. |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
2009-07-02 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-07-02 |
Time |
13:46 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-07-02 |
Time |
13:46 |
Sent To |
|
|
| Notes |
| 2009-07-02 13:47:05 | ***LANDSCAPE REVIEW FAILED*** | | | | | | PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN WRITTEN | | | FORMAT. | | | | | | 1 .PURSUANT TO SECTION 94-441(C)(2), WHEN RENOVATIONS, | | | REPAIR, ALTERATION OR REDEVELOPMENT EXCEEDS 50 PERCENT | | | OF THE VALUE OF THE STRUCTURE, THE ENTIRE LANDSCAPING | | | ON SITE SHALL BE BROUGHT UP TO CURRENT STANDARDS. | | | | | | 2. PLEASE SUBMIT A LANDSCAPE PLAN WITH ALL ALL | | | TABULATION NECESARY FOR THE EVALUATION OF COMPLIANCE | | | WITH ARTICLE XIV OF THE ZONING AND LAND DEVELOPMENT | | | REGULATIONS, INCLUDING THE XERISCAPE DESIGN OPTIONS. | | | | | | 3. SUBMIT A COST ESTIMATE THAT INCLUDES THE TOTAL COST | | | OF ALL LANDSCAPE MATERIALS AND LABOR, BROKEN DOWN INTO | | | UNIT COST. | | | | | | 4. AN IRRIGATION PERMIT IS REQUIRED. THERE SHALL BE | | | 120% COVERAGE TO ALL AREAS INCLUDING THE RIGHT-OF-WAY. | | | IN ADDITION, A RAIN SENSING DEVICE IS REQUIRED. | | | | | | | | | | | | IF YOU HAVE ANY QUESITONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2009-09-24 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-09-24 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-09-24 |
Time |
16:04 |
Sent To |
|
|
| Notes |
| 2009-09-24 16:37:39 | 1) SUBMIT REVISED MECHANICAL PLANS INDICATING THE SIZES | | | OF THE TRANSFER DUCT AND GRILLS BETWEEN THE DINING ROOM | | | AND BEDROOM #1. | | | | | | 2) THE WHOLE HOUSE FAN CREDIT HAS BEEN TAKEN ON THE | | | ENERGY CALCULATIONS. SUBMIT REVISED PLANS SHOWING THE | | | LOCATION OF THE WHOLE HOUSE FAN AND PROVIDE | | | DOCUMENTATION SHOWING HOW THE THREE REQUIREMENTS OF | | | 2007 FBC RESIDENTIAL ENERGY GLITCH AMENDMENTS B4.1.4 | | | WILL BE MET. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2009-08-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-08-10 |
Time |
15:41 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-08-10 |
Time |
15:41 |
Sent To |
|
|
| Notes |
| 2009-08-10 15:42:28 | 2007 FBC W/2009 REVISIONS | | | LEVEL 1 ALTERATION | | | | | | DENIED | | | | | | (1) SUBMIT TWO SETS OF HEATING AND COOLING EQUIPMENT | | | SIZING CALCULATIONS IN ACCORDANCE WITH ACCA MANUAL J OR | | | OTHER APPROVED METHODOLOGIES AS REQUIRED BY FBC R | | | M1401.3. AND REQUESTED IN FIRST REVIEW COMMENTS. | | | | | | (2) THE TWO SETS OF MECHANICAL PLANS THAT WERE | | | SUBMITTED ARE NOT ADEQUATE. IN ADDITION TO THE GRILL | | | SIZES, SPECIFY THE DUCT SIZES AND CFM AT EACH SUPPLY | | | GRILL ON THE PLANS. SPECIFY THE SIZE AND LOCATION OF | | | THE RETURN AIR SYSTEM. PLEASE SPECIFY THE ADDRESS OF | | | THE PROJECT AND THE PERSON RESPONSIBLE FOR THE DESIGN | | | ON THE PLANS. SEE FBC R M1601 AND N1110.AB.1 OF THE | | | 2007 ENERGY GLITCH AMENDMENTS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2009-07-13 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-07-13 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-07-13 |
Time |
09:20 |
Sent To |
|
|
| Notes |
| 2009-07-13 09:25:39 | 2007 FBC | | | RENOVATION | | | | | | DENIED | | | 1) THE SCOPE OF WORK STATES " A/C EVALUATE AND | | | INSTALL". IF THIS MEANS THAT A NEW A/C SYSTEM WITH NEW | | | DUCT WORK IS TO BE INSTALLED, THEN A MECHANICAL PERMIT, | | | TWO SETS OF PLANS AND TWO SETS OF EQUIPMENT SIZING | | | CALCULATIONS ARE REQUIRED. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2009-07-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-07-06 |
Time |
12:07 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-07-06 |
Time |
12:07 |
Sent To |
|
|
| Notes |
| 2009-07-06 12:09:26 | NO PLUMBING PLANS SUBMITTED. -- CHANGE OUT OF FIXTURES | | | IN SAME LOCATION -- PLUMBING PERMIT REQUIRED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2009-10-05 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2009-10-05 |
Time |
12:09 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2009-10-05 |
Time |
12:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2009-09-21 |
|
|
Cont ID |
|
| Sent By |
astelly |
Date |
2009-09-21 |
Time |
18:02 |
Rev Time |
0.00 |
| Received By |
astelly |
Date |
2009-09-21 |
Time |
18:17 |
Sent To |
E |
|
| Notes |
| 2009-09-21 18:14:35 | AMY STELLY | | | PLANNING AND ZONING | | | 561-822-1442 | | | | | | PLEASE RESPOND TO THE REPEAT COMMENTS BELOW: | | | | | | 1. PLEASE PROVIDE ALL RESPONSES IN WRITING. | | | | | | 2. PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH | | | INCLUDES THE PROPERTY'S ADDRESS AND LEGAL DESCRIPTION. | | | | | | 3. INDICATE SETBACK DIMENSIONS FROM PROPOSED/RELOCATED | | | A/C EQUIPMENT TO ALL PROPERTY LINES. PURSUANT THE ZLDR: | | | SECTION 94-305(B) (4): MECHANICAL EQUIPMENT MAY NOT | | | PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK. | | | | | | NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY | | | GENERATE ADDITIONAL COMMENTS. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2009-08-03 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2009-08-03 |
Time |
15:09 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2009-08-02 |
Time |
21:33 |
Sent To |
B |
|
| Notes |
| 2009-08-03 15:09:21 | PLANNING AND ZONING DEPT: ***ZONING FAILED*** | | | | | | 1. PLEASE PROVIDE ALL RESPONSES IN WRITING. | | | | | | 2. PLEASE ADDRESS LANDSCAPE PLANNER COMMENTS. | | | | | | NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY | | | GENERATE ADDITIONAL COMMENTS. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1444 OR (561) 805-6720 | | | E-MAIL: [email protected] | | | | | | PLACED IN R28 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2009-07-01 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2009-07-01 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2009-07-01 |
Time |
14:08 |
Sent To |
|
|
| Notes |
| 2009-07-01 14:13:05 | PLANNING AND ZONING DEPT: ***ZONING FAILED*** | | | | | | 1. PLEASE PROVIDE ALL RESPONSES IN WRITING. | | | | | | 2. PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH | | | INCLUDES THE PROPERTY'S ADDRESS AND LEGAL DESCRIPTION. | | | | | | 3. PURSUANT TO THE CITY OF WEST PALM BEACH ZONING AND | | | LAND DEVELOPMENT REGULATIONS (ZLDR), SECTION | | | 94-441(C)(2) OF: AS THE VALUE OF THE PROPOSED WORK | | | EXCEEDS 50% OF THE STRUCTURE'S VALUE (LISTED AS | | | "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY | | | APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE | | | WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF | | | THE ZLDR. | | | | | | PLEASE SUBMIT TWO (2) COPIES OF A LANDSCAPE PLAN | | | SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF | | | THE ZLDR. | | | | | | 4. INDICATE ON THE SURVEY THE SETBACK DIMENSIONS FROM | | | ANY EXTERIOR IMPROVEMENTS TO ALL ADJACENT PROPERTY | | | LINES. PURSUANT TO THE ZLDR, SECTION 94-73(B)(2): | | | SINGLE-FAMILY/SMALL LOT (SF11) HIGH DENSITY RESIDENTIAL | | | DISTRICT. - MINIMUM SETBACKS FOR PRINCIPAL BUILDING ARE | | | AS FOLLOWS: | | | | | | A. FRONT: 20 FEET OR 20 PERCENT OF LOT DEPTH, WHICHEVER | | | IS LESS; | | | | | | B. CORNER: TEN FEET OR TEN PERCENT OF LOT DEPTH, | | | WHICHEVER IS LESS; | | | | | | C. REAR: TEN FEET OR TEN PERCENT OF LOT DEPTH, | | | WHICHEVER IS LESS; | | | | | | D. SIDE: FIVE FEET MINIMUM, TEN FEET TOTAL. | | | | | | 5. INDICATE SETBACK DIMENSIONS FROM PROPOSED/RELOCATED | | | A/C EQUIPMENT TO ALL PROPERTY LINES. PURSUANT THE ZLDR, | | | SECTION 94-305(B)(4): MECHANICAL EQUIPMENT MAY NOT | | | PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK. | | | | | | NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY | | | GENERATE ADDITIONAL COMMENTS. | | | | | | FOR ADDITIONAL INFORMATION, THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT | | | WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH | | | PLANNING DEPARTMENT WEBSITE AT | | | WWW.CITYOFWPB.COM/PLAN/INDEX.HTM. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO | | | CONTACT ME. | | | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1444 OR (561) 805-6720 | | | E-MAIL: [email protected] | | | | | | PLACED ON SF RACK R19 | | | |
|
|