| Plan Review Stops For Permit 09060284 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2009-07-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-07-28 |
Time |
14:45 |
Rev Time |
0.33 |
| Received By |
jwitmer |
Date |
2009-07-28 |
Time |
14:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2009-07-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-07-08 |
Time |
08:50 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
2009-07-08 |
Time |
08:20 |
Sent To |
|
|
| Notes |
| 2009-07-08 08:38:15 | BUILDING PLAN REVIEW | | | PERMIT: 09060285 | | | ADD: 650 BELVEDERE RD | | | CONT: CORE STATES CONSTRUCTION | | | TEL: (561)997-6273 | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1ST REVIEW | | | ACTION: DENIED | | | | | | 1) INFORMATIONAL: WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE & REPLACE ANY PAGES AS | | | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE | | | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO | | | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTI | | | 1E) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) | | | AFTER MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC | | | BUILDING WITH 2009 SUPPLEMENTS. | | | | | | PLANS WILL ALSO BE REVIEWED TO THE 2007 EXISTING | | | BUILDING CODE W/ 2009 SUPPLEMENTS, PLEASE INDICATE TO | | | WHAT LEVEL ALTERATION WILL BE COMPLETED UNDERTHIS | | | PERMIT. | | | 401.4 A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE | | | OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO | | | SECTIONS 403, 404 AND 405 OF THIS CODE. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | SURVEY: | | | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2009-07-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-07-30 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-07-30 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2009-07-30 16:07:09 | ELEC SUB PERMIT AND LV SUB PERMITS REQUIRED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2009-07-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-07-05 |
Time |
12:22 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-07-05 |
Time |
12:10 |
Sent To |
|
|
| Notes |
| 2009-07-05 12:22:33 | | | | ** DENIED PLANS REVIEW ** | | | | | | 1) NOTE: PLEASE BE SURE THE FOLLOWING MINIMUM CODES ARE | | | STATED ON PLANS AS THEY ARE RELEVANT FOR THE MINIMUM | | | DESIGNS. | | | 2007 FBC W/ 2009 SUPPLEMENTS | | | 2005 NFPA-70 | | | 2006 NFPA-101 | | | | | | 2) NOTE: THE ENGINEERING FIRM SHALL INCLUDE ALL | | | REQUIRED INFORMATION ON TITLE BLOCKS PER FAC | | | 61G15-23.002. PLEASE ALSO SEE THE SAME SECTION OF THE | | | FLORIDA ADMINISTRATIVE CODE REQUIRES THE CERTIFICATE OF | | | AUTHORIZATION NUMBER. THIS IS AN REQUIRED LICENSE | | | NUMBER PER FLORIDA STATUTES 471.023 | | | IF THERE ARE ANY QUESTIONS ON HOW TO PROCEED PLEASE | | | CALL. | | | | | | 3) NOTE: PLEASE SEE 13-415.AB.5. PLEASE PROVIDE SPACE | | | OF NEW WORK SHOWING NEW LIGHTING TO EXISTING. THE | | | ADDITION OF NEW LIGHTING TO EXISTING MAY OR MAY NOT | | | EXCEED LIGHTING LEVELS PERMITTED. | | | PLEASE CALL TO GO OVER AS ALLOWANCES IN THE FBC AS THEY | | | HAVE CHANGED SUBSTANTIALLY. THE LIGHTING LAYOUT ON | | | PLANS DOES NOT SEEM TO COORDINATE WITH THE ACTUAL | | | LOCATION FOR ALL LIGHTS. | | | | | | *** ALL LOW VOLTAGE WORK SHALL BE UNDER SEPARATE | | | PERMITS. | | | | | | ** IMPORTANT ** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2009-08-05 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-08-05 |
Time |
11:24 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-08-05 |
Time |
11:14 |
Sent To |
|
|
| Notes |
| 2009-08-05 11:24:46 | *****APPROVED***** | | | | | | | | | PLAN SHEET A1.0 STAMPED, INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2009-07-14 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-07-14 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-07-14 |
Time |
14:21 |
Sent To |
|
|
| Notes |
| 2009-07-14 14:25:35 | *****FIRE STAMPING NEEDED***** | | | | | | THE APPROPIATE PLAN SHEET(S) TO BE FIRE-STAMPED WHEN | | | THE OTHER PLAN REVIEWERS' COMMENTS HAVE BEEN ADDRESSED. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2009-07-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-07-17 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-07-17 |
Time |
12:55 |
Sent To |
|
|
| Notes |
| 2009-07-17 13:02:40 | SENT TO C-2. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2009-07-14 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-07-14 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-06-12 |
Time |
09:42 |
Sent To |
|
|
| Notes |
| 2009-06-12 13:30:20 | SENT TO COMMERCIAL C28 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2009-08-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-08-06 |
Time |
16:23 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-08-06 |
Time |
16:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2009-07-02 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-07-02 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-07-02 |
Time |
16:08 |
Sent To |
|
|
| Notes |
| 2009-07-02 16:09:51 | DENIED | | | REFERENCE: | | | FBC-2007 PLUMBING | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. SHT P1.0 THE FIRM LICENSE NUMBER, (CERTIFICATE OF | | | AUTHROIZATION), IS REQUIRED IN THE TITLE BLOCK OF EACH | | | SHEET. FAC 61G1-16.004(2) & FS 481.2055. | | | | | | 2, SHT P1.0 THE PRINTED NAME OF THE PERSON SEALING THE | | | PLANS IS REQUIRED ON EACH SHEET. FAC 61G1-16.004(6) & | | | FS 481.2055. | | | | | | 3. SHT P1.0 THE REVERSE OSMOSIS SHALL MEET THE | | | REQUIREMENTS OF NFS 58. OTHER WATER FILTERS SHALL MEET | | | THE REQUIREMENTS OF NSF 42. PLEASE SUBMIT MANUF. | | | SPECIFICATION SHEETS SHOWING COMPLIANCE. SECTION 611.2. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2009-06-15 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2009-06-15 |
Time |
09:40 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2009-06-15 |
Time |
09:39 |
Sent To |
|
|
| Notes |
| 2009-06-15 09:42:15 | VALUE OF PERMIT IS $50,000 WHICH IS LESS THAN 50% OF | | | THE VALUE OF THE STRUCTURE. | | | | | | NOTE THAT IMPROVEMENTS WITHIN ANY ONE YEAR PERIOD | | | EXCEEDING 50% OF THE VALUE OF THE STRUCTURE WILL | | | REQUIRE VERIFICATION THAT THE LANDSCAPE ON SITE MEETS | | | THE ORIGINALLY APPROVED PLAN OR THE CURRENT CITY | | | LANDSCAPE REQUIREMENTS. |
|
|