Plan Review Details - Permit 09060278
Plan Review Stops For Permit 09060278
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-07-27 Cont ID  
Sent By shill Date 2009-07-27 Time 10:13 Rev Time 0.00
Received By shill Date 2009-07-27 Time 10:13 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-06-22 Cont ID  
Sent By shill Date 2009-06-22 Time 16:55 Rev Time 0.00
Received By shill Date 2009-06-22 Time 16:55 Sent To  
Notes
2009-06-22 17:04:36****CORRECTIONS****
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
 FBC FLORIDA BUILDING CODE 2007
 FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL
  
 1. PLEASE REVISE GOVERNING CODE, INCLUDING 2009
 SUPPLEMENTS.
  
 2. INCORRECT ASCE 7 REFERENCE, SEE FBC 35.
  
 3. THIS PROPERTY IS IN EXPOSURE C, PLEASE REVISE PLANS,
 DESIGN CRITERIA, TRUSS ENGINEERING, ETC. AS NECESSARY.
 FBC1609, ASCE7-05.
  
 4. PLEASE SUBMIT TWO SETS OF ONE PRODUCT APPROVAL FOR
 THE SHINGLES. SEVERAL DIFFERENT NOAS SUBMITTED. PLEASE
 PROVIDE TWO COMPLETE SETS OF ONE NOA.
  
 5. PLEASE CLARIFY, 25 PSF ATTIC LIVE LOAD SPECIED ON
 PLAN, NOT INCLUDED ON TRUSS ENGINEERING, NO ATTIC
 ACCESS, BUT THIS IS A SCISSOR TRUSS. HOW WILL YOU
 ACCOMODATE A 25PSF LIVE LOAD IN THE LIMITED SPACE?
  
 6. DESIGNER OF RECORD IS TO REVIEW THE TRUSS
 ENGINEERING, FAC61G31.
  
 7. PROVIDE A SITE PLAN WHICH SHOWS THE PROPOSED
 IMPROVEMENT IN RELATION TO THE PROPERTY LINE AND
 EXISTING STRUCTURE, FBC R301.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-07-01 Cont ID  
Sent By kstevens Date 2009-07-01 Time 08:50 Rev Time 0.00
Received By kstevens Date 2009-07-01 Time 08:50 Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-06-22 Cont ID  
Sent By shill Date 2009-06-22 Time 17:04 Rev Time 0.00
Received By shill Date 2009-06-12 Time 10:45 Sent To  
Notes
2009-06-12 10:49:43SENT TO ZONING

Review Stop Z ZONING
Rev No 2 Status P Date 2009-07-05 Cont ID  
Sent By mcruz Date 2009-07-05 Time 15:27 Rev Time 0.00
Received By mcruz Date 2009-07-05 Time 15:24 Sent To B
Notes
2009-07-05 15:28:07ROUTED TO SH

Review Stop Z ZONING
Rev No 1 Status F Date 2009-06-20 Cont ID  
Sent By mcruz Date 2009-06-20 Time 11:14 Rev Time 0.00
Received By mcruz Date 2009-06-20 Time 11:12 Sent To B
Notes
2009-06-20 11:14:47PLANNING AND ZONING DEPT: ***ZONING FAILED***
  
 1. PLEASE PROVIDE ALL RESPONSES IN WRITING.
  
 2. INDICATE ON THE SURVEY THE SETBACK DIMENSIONS FROM
 ANY EXTERIOR IMPROVEMENTS TO ALL ADJACENT PROPERTY
 LINES. PURSUANT TO THE ZLDR, SECTION 94-72(A)(2):
 SINGLE-FAMILY LOW DENSITY (SF7) RESIDENTIAL DISTRICT -
 MINIMUM SETBACKS FOR PRINCIPAL BUILDING ARE AS FOLLOWS:
  
 A. FRONT: 25 FEET;
  
 B. CORNER: 12.5 FEET;
  
 C. REAR: 15 FEET OR TEN PERCENT OF LOT DEPTH, WHICHEVER
 IS LESS;
  
 D. SIDE: FIVE FEET MINIMUM, 15 FEET TOTAL.
  
  
 NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY
 GENERATE ADDITIONAL COMMENTS.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  
 PLACED IN MISC #2


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved