Plan Review Details - Permit 09060182
Plan Review Stops For Permit 09060182
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2010-04-28 Cont ID  
Sent By jwitmer Date 2010-04-28 Time 14:17 Rev Time 0.77
Received By jwitmer Date 2010-04-28 Time 14:17 Sent To  
Notes
2010-04-28 14:21:42BUILDING REVISIONS:
 A1.1 REV# 3
 BUILDING PROVISO: DOOR # 2 WILL REQUIRE 12" PUSH SIDE
 11-4.13.6 MANEUVERING CLEARENCES , FIGURE 25 (A).
 A1.2 REV# 2
 A1.3 REV# 1
 A2.1 REV# 3
 A3.1 REV#2

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-10-20 Cont ID  
Sent By rmcdouga Date 2009-10-20 Time 10:02 Rev Time 0.00
Received By rmcdouga Date 2009-10-20 Time 10:02 Sent To  
Notes
2009-10-20 10:04:51REVISED SHEETS A1.1, A1.2, A2.1 REVIEWED FOR CODE
 COMPLIANCE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-07-21 Cont ID  
Sent By shill Date 2009-07-21 Time 21:16 Rev Time 0.00
Received By shill Date 2009-07-21 Time 21:16 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2009-06-23 Cont ID  
Sent By jwitmer Date 2009-06-23 Time 07:30 Rev Time 1.33
Received By jwitmer Date 2009-06-22 Time 16:01 Sent To  
Notes
2009-06-23 07:33:25BUILDING PROVISO:
 SUBMIT FLOOR INSULATION TYPE BEFORE INSPECTION:
 1207.3 STRUCTURE-BORNE SOUND. FLOOR/CEILING ASSEMBLIES
 BETWEEN DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A
 PUBLIC OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE
 AN IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS
 THAN 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE
 WITH ASTM E 492.
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2009-10-16 Cont ID  
Sent By dpalmer Date 2009-10-16 Time 12:54 Rev Time 0.00
Received By dpalmer Date 2009-10-16 Time 12:54 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2009-07-21 Cont ID  
Sent By dpalmer Date 2009-07-21 Time 18:44 Rev Time 0.00
Received By dpalmer Date 2009-07-21 Time 18:44 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2009-07-03 Cont ID  
Sent By dpalmer Date 2009-07-03 Time 09:26 Rev Time 0.00
Received By dpalmer Date 2009-07-03 Time 09:26 Sent To  
Notes
2009-07-03 09:26:31 
 ** DENIED PLANS *
  
 1) NOTE: THE ELECTRICAL PLANS NEED TO STATE THE
 FOLLOWING MINIMUM CODES.
 PLEASE BE SURE THE FOLLOWING ARE STATED ON ELECTRICAL
 PLANS.
 2007 FBC W/ 2009 AMENDMENTS.
 2006 NFPA-101 ( PLANS STATE 2007 FOR THIS CODE)
 2002 NFPA-72 (OK)
 2006 NFPA-1
 2005 NFPA-70 ( PLANS STATE 2007) PLEASE BE ADVISED EVEN
 ONCE THE CODE CHANGE GOES INTO AFFECT THE IT WILL BE
 THE 2008 NEC.
  
 PER: FBC CHAPTER 35, FS 553.73, FAC 69A-60.004, .003
  
  
 2) NOTE: PLEASE SEE 210.8B2 FOR ALL RECEPTACLES IN
 KITCHEN AREAS TO BE GFI OR GFI PROTECTED WHETHER OR NOT
 THEY SERVE COUNTER SPACES. THE CODE WAS REVISED THAT IT
 IS NO LONGER ONLY RECEPTACLES WITHIN 6FT OF SINKS. THIS
 WOULD INCLUDE AREAS WHERE KITCHEN EQUIPMENT SUCH AS ICE
 MACHINES, DISHWASHERS AND OTHER SERVICE EQUIPMENT IS
 LOCATED. AREAS WHERE FLOORS ETC ARE WET IS A HIGH AREA
 OF HAZARD IN KITCHENS IN COMMERCIAL LOCATIONS. PLEASE
 SEE COMMENTARY IN THE 2005 NEC.
  
 3) NOTE: PLEASE INCLUDE ALL DEVICE LOCATIONS, HEIGHTS,
 AND MINIMUM LEVELS PER FBC 11-4.28.1,.2 AND .3.
 THERE ARE SOME DEVICES ON PLANS HOWEVER NO DETAILS OR
 INFORMATION ON SYMBOL LEGEND.
  
 4) NOTE: PLEASE SUBMIT LIGHTING PERFORMANCE
 CALCULATIONS IN ACCORDANCE WITH THE FLORIDA BUILDING
 CODE 13-415.AB.5. IS THERE OTHER EXISTING LIGHTING?
  
 5) NOTE: PLEASE SHOW LIGHTING PER NFPA-101 7.8,
 7.9.2.1,.2.2. NO BATTERY BACK UP FIXTURES SHOWN FOR
 MINIMUM EGRESS LIGHTING.
 ** PLEASE KEEP IN MIND THE BUILDING SHALL NOT BE
 OCCUPIED UNDER EMERGENCY POWER. IF OCCUPIED UNDER
 EMERGENCY POWER IF THE GENERATOR BREAKER IS TRIPPED OR
 LOST THEN NO EGRESS LIGHTING WOULD BE PROVIDED. THIS
 COULD LEAVE LIFE SAFETY EGRESS AREAS IN TOTAL DARKNESS.
 PLEASE BE SURE TO GO OVER THIS WITH BUILDING
 OWNER/MANAGEMENT.
 OBTAIN IN WRITING THAT BUILDING SHALL NOT BE OCCUPIED
 UNDER EMERGENCY POWER.
  
 6) NOTE: PLEASE INDICATE THE REQUIRED LIGHTING CONTROLS
 PER FBC 13-415.AB.1,.1.2, .1.3. SOME ARE SHOWN ON PLANS
 HOWEVER NOT ALL. SEE AREAS 200,201, ONLY WHAT APPEARS
 AS A SINGLE POLE SWITCH IS SHOWN. AS THE SYMBOL LEGEND
 DOES NOT INCLUDE THIS DEVICE IT IS UNCLEAR AT THIS
 TIME. OTHER AREAS IN THE BACK OF HOUSE DO SHOW THE
 REQUIRED CONTROLS.
  
 7) NOTE: PLEASE SEE 422.13, WATER HEATER LOAD IS
 CONSIDERED CONTINUOUS WHICH REQUIRES THIS TO BE FIGURED
 AT 125%.
  
  
  
  
  
 ** IMPORTANT **
 ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP
 FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE
 ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING.
 DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY
 ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS,
 SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED
 INTO TWO SETS/FOLDERS/BINDERS ETC.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID
 ANY DELAYS.
  
 IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT
 TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO
 CONTACT THIS REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2009-07-22 Cont ID  
Sent By mawillia Date 2009-07-22 Time 11:56 Rev Time 0.00
Received By mawillia Date 2009-07-22 Time 11:42 Sent To B
Notes
2009-07-22 11:46:17*****APPROVED*****
  
 THE PROVISO(S) FROM THE PREVIOUS FIRE PLAN REVIEW HAVE
 BEEN ADDRESSED; PLAN SHEETS A1.1, A1.3, A2.1, A3.1, AND
 E1 WERE STAMPED, INITIALED, AND DATED.
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2009-06-30 Cont ID  
Sent By mawillia Date 2009-06-30 Time 14:04 Rev Time 0.00
Received By mawillia Date 2009-06-30 Time 13:39 Sent To  
Notes
2009-06-30 13:55:33*****PROVISO*****
  
  
 1. STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241 - 2004
 EDITION.
  
 2. ON SHEET A3.1, GENERAL NOTE #8 AND #9 REFERENCES
 FLORIDA FIRE PREVENTION CODE - 2004 EDITION. CORRELATE
 TO CURRENT EDITION AS CORRECTLY SHOWN ON SHEET T UNDER
 CODES.
  
 3. ON SHEET A3.1, THE NEW FIRE RATED DOOR (DOOR A)
 SHALL BE 20 MINUTES.
  
  
 THE APPROPIATE PLAN SHEET(S) TO BE FIRE-STAMPED WHEN
 THE ABOVE AS WELL AS OTHER PLAN EXAMINER(S)' COMMENTS
 HAVE BEEN ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722
  
  
 .
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2009-07-09 Time   Rev Time 0.00
Received By rmcdouga Date 2009-06-08 Time 11:51 Sent To PC
Notes
2009-06-17 11:50:31TO B9

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2009-10-16 Cont ID  
Sent By rregueir Date 2009-10-16 Time 11:29 Rev Time 0.00
Received By rregueir Date 2009-10-16 Time 11:24 Sent To E
Notes
2009-10-16 11:29:53REVISED M1 DELTA 5, M2 DELTA 1

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2009-07-09 Cont ID  
Sent By rregueir Date 2009-07-09 Time 10:01 Rev Time 0.00
Received By rregueir Date 2009-07-09 Time 10:01 Sent To  
Notes
2009-07-09 10:11:58NEW EXHAUST SYSTEM SHOWN ON PLANS IS NOT FOR COMMERCIAL
 COOKING OPERATIONS.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop P PLUMBING
Rev No 3 Status P Date 2009-10-21 Cont ID  
Sent By kstevens Date 2009-10-21 Time 09:43 Rev Time 0.00
Received By kstevens Date 2009-10-21 Time 09:43 Sent To  
Notes
2009-10-21 09:44:24REVISIONS OK -- SHTS P1 & P2.

Review Stop P PLUMBING
Rev No 2 Status P Date 2009-07-22 Cont ID  
Sent By kstevens Date 2009-07-22 Time 15:54 Rev Time 0.00
Received By kstevens Date 2009-07-22 Time 15:54 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2009-06-18 Cont ID  
Sent By kstevens Date 2009-06-18 Time 10:01 Rev Time 0.00
Received By kstevens Date 2009-06-18 Time 10:01 Sent To  
Notes
2009-06-18 10:42:59DENIED
 REFERENCE:
 FBC-2007 PLUMBING
 CITY WPB MUNICIPAL CODE
  
 1. SHTS P1 & P2 FIXTURES UTILIZED FOR THE STORAGE,
 PREPARATION, AND THE HANDLING OF FOOD SHALL DISCHARGE
 THROUGH AN INDIRECT WASTE PIPE BY MEANS OF AN AIR GAP.
 SECTION 802.1.1. ARE HE SINKS IN THE SERVICE AREA TO BE
 USED FOR FOOD PREPARATION? PLEASE CLARIFY.
  
 2. THE GREASE INTERCEPTOR SHALL BE SIZED BY THE UTILITY
 DEPARTMENT, ENVIRONMENTAL COMPLIANCE. PLEASE CONTACT
 HOLLY MCGRATH, LABORATORY SUPERVISOR BY PHONE (561)
 822-2271, BY FAX (561) 822-2279, OR BY E-MAIL
 [email protected]. A WRITTEN DETERMINATION OR E-MAIL
 FROM HMCGRATH IS REQUIRED FOR OUR FILES. ARTICLE III
 SECTION 90-124(7).
  
 3. IF A FOOD WASTE GRINDER IS CONNECTED TO THE GREASE
 TRAP, A SOLIDS INTERCEPTOR IS REQUIRED PER SECTION
 1003.3.2. PLEASE INDICATE IF A FOOD WASTE GRINDER IS TO
 BE CONNECTED.
  
 4. GREASE TRAPS SHALL BE EQUIPPED WITH DEVISES TO
 CONTROL THE RATE OF WATER FLOW SO THAT THE WATER FLOW
 DOES NOT EXCEED THE RATED FLOW. THE FLOW-CONTROL DEVISE
 SHALL BE VENTED AND TERMINATE NOT LESS THAN 6 INCHES
 ABOVE THE FLOOD RIM LEVEL OR BE INSTALLED IN ACCORDANCE
 WITH THE MANUFACTURE'S INSTRUCTIONS. THE FLOW DEVISE &
 VENT ARE NOT INDICATED ON THE PLANS.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  
  