| Plan Review Stops For Permit 09060129 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2009-10-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-10-26 |
Time |
09:46 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2009-10-26 |
Time |
09:46 |
Sent To |
|
|
| Notes |
| 2009-10-26 10:07:57 | BUILDING PROVISO: | | | | | | 1) SKWTCH SK-2 THE FRAME WALL DOES NOT INDICATE IF THIS | | | IS INTERIOR OR | | | EXTERIOR, IF CONSIDERED EXTERIOR COMPLY WITH: | | | | | | 2304.11.2.6 WOOD SIDING. CLEARANCE BETWEEN WOOD SIDING | | | AND EARTH | | | ON THE EXTERIOR OF A BUILDING SHALL NOT BE LESS THAN 6 | | | INCHES (152 MM) | | | EXCEPT WHERE SIDING, SHEATHING AND WALL FRAMING ARE OF | | | NATURALLY DURABLE | | | OR PRESERVATIVE-TREATED WOOD. | | | | | | 2) NO ROOFING PERMIT HAS BEEN APPLIED FOR AT THIS TIME | | | (10-26-09) | | | FL S S 489.13 QUALIFICATIONS FOR PRACTICE; RESTRICTIONS | | | (2) (B) A GENERAL, BUILDING ,OR RESIDENTIAL CONTRACTOR | | | SHALL NOT BE REQUIRED TO SUBCONTRACT THE INSTALLATION, | | | OR REPAIR MADE UNDER WARRANTY, OF WOOD SHINGLES, WOOD | | | SHAKES, OR ASPHALT OR FIBERGLASS SHINGLE ROOFING | | | MATERIALS ON A NEW BUILDING OF HIS CONSTRUCTION. | | | (G) NO GENERAL, BUILDING OR RESIDENTIAL CONTRACTOR | | | CERTIFIED AFTER 1973 SHALL ACT AS, HOLD HIMSELF OUT TO | | | BE, OR ADVERTISE HIMSELF TO BE A ROOFING CONTRACTOR | | | UNLESS HE IS CERTIFIED OR REGISTERED AS A ROOFING | | | CONTRACTOR. | | | | | | THE FLAT ROOF AND ASSOCIATED NOA'S WILL REQUIRE EITHER | | | A REGISTER OR CERTIFIED ROOFING CONTRACTOR TO APPLY AND | | | RECEIVE A ROOFING PERMIT. | | | | | | THE NOA SUBMITTED WITH ENHANCED FASTENING REVIEWED: | | | NOA 09-0224.01 | | | GAF CORP PAGES 29-30, SYSTEM TYPE:E2 | | | DESIGN PRESSURE -60 PSF | | | EXPOSURE : C | | | ATLANTIC & CARIBBEAN ROOFING CONSULTING, LLC ENHANCED | | | FASTENING P2=71.68 & P3 -101.2. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2009-08-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-08-11 |
Time |
09:48 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2009-08-11 |
Time |
09:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2009-07-07 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-07-07 |
Time |
12:50 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2009-07-07 |
Time |
12:11 |
Sent To |
|
|
| Notes |
| 2009-07-07 12:34:04 | BUILDING PLAN REVIEW | | | PERMIT: 09060129 | | | ADD: 8020 S DIXIE HWY | | | CONT: FERGUSON CONTRACTING CORP OF SOUTH FL | | | TEL: (561)746-3300 | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER | | | MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC | | | BUILDING WITH 2009 SUPPLEMENTS, PLEASE UPDATE PLANS | | | PLANS WILL ALSO BE REVIEWED TO THE 2007 EXISTING | | | BUILDING CODE W/ 2009 SUPPLEMENTS, PLEASE INDICATE TO | | | WHAT LEVEL ALTERATION WILL BE COMPLETED UNDERTHIS | | | PERMIT. | | | 401.4 A DESIGN PROFESSIONAL OR AN OWNER MUST ELECT ONE | | | OR A COMBINATION OF LEVELS OF ALTERATION PURSUANT TO | | | SECTIONS 403, 404 AND 405 OF THIS CODE. | | | | | | 2) PLANS WILL NEED TO INDICATE WIND DESIGN INFORMATION: | | | 1603.1.4 WIND DESIGN DATA. | | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | | DESIGN OF THE LATERAL-FORCE-RESISTING SYSTEM OF THE | | | BUILDING: | | | 2.1. BASIC WIND SPEED (3-SECOND GUST), MILES PER HOUR | | | (KM/HR). | | | | | | 2.2. WIND IMPORTANCE FACTOR, I W , AND BUILDING | | | CLASSIFICATION FROM TABLE 1604.5 OR TABLE 6-1, ASCE 7 | | | AND BUILDING CLASSIFICATION IN TABLE 1-1, ASCE 7. | | | | | | 2.3. WIND EXPOSURE, IF MORE THAN ONE WIND EXPOSURE IS | | | UTILIZED, THE WIND EXPOSURE AND APPLICABLE WIND | | | DIRECTION SHALL BE INDICATED. | | | | | | 2.4. THE APPLICABLE ENCLOSURE CLASSIFICATIONS AND, IF | | | DESIGNING WITH ASCE 7, INTERNAL PRESSURE COEFFICIENT. | | | | | | 2.5. COMPONENTS AND CLADDING. THE DESIGN WIND PRESSURES | | | IN TERMS OF PSF (KN/M 2 ) TO BE USED FOR THE SELECTION | | | OF EXTERIOR COMPONENTS AND CLADDING MATERIALS NOT | | | SPECIFICALLY DESIGNED BY THE REGISTERED DESIGN | | | PROFESSIONAL. | | | | | | 3) PLEASE INDICATE COMPLIANCE WITH : (19) ASSEMBLY | | | AREAS. A) ALL PUBLIC FOOD SERVICE ESTABLISHMENTS, ALL | | | ESTABLISHMENTS LICENSED UNDER THE BEVERAGE LAW FOR | | | CONSUMPTION ON THE PREMISES, AND PLACES OF ASSEMBLY | | | WITH FIXED SEATING SHALL PROVIDE ACCESSIBLE SEATING OR | | | SPACES FOR SEATING WHICH COMPLY WITH SECTIONS | | | 11-4.33.2, 11-4.33.3, AND 11-4.33.4 AND IN ACCORDANCE | | | WITH THE FOLLOWING REQUIREMENTS: FOR THE FIRST 100 | | | SEATS, ACCESSIBLE AND USABLE SPACES SHALL BE PROVIDED | | | CONSISTENT WITH THE FOLLOWING TABLE:1 TO 25 / 1 | | | REQUIRED WHEELCHAIR LOCATION. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | SURVEY: | | | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2009-08-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-08-11 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-08-11 |
Time |
10:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2009-06-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-06-30 |
Time |
17:02 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-06-29 |
Time |
16:59 |
Sent To |
|
|
| Notes |
| 2009-06-30 17:02:11 | | | | | | | | | | ** DENIED REVIEW ** | | | | | | 1) NOTE: PLEASE SUBMIT PLANS SHOWING MINIMUM DESIGNS | | | AND INSTALLATIONS PER CODES WHICH ARE REQUIRED TO BE | | | REFLECTED ON PLANS. | | | THE INCORRECT CODES ARE STATED. PLANS INDICATE THE | | | PREVIOUS 2004 FBC WHICH HAS NOT BEEN AN ADOPTED CODE | | | SINCE MARCH 1ST, 2009. | | | PLANS SHOULD REFLECT THE FOLLOWING CODES COORDINATION | | | BETWEEN PLANS IS NEED. ELECTRICAL PLANS STATE DIFFERENT | | | CODES FROM BUILDING. | | | PLANS REFERENCE 2002 NFPA-72, WILL THERE BE ANY WORK | | | PER THIS CODE? | | | | | | 2007 FBC WITH 2009 REVISIONS | | | 2005 NFPA-70 | | | 2006 NFPA-101 | | | | | | 2) NOTE: PLEASE SEE FBC 13-415.AB.5 FOR MINIMUM | | | LIGHTING PERFORMANCE CALCULATIONS. FIXTURES NEED TO BE | | | COMPLETE AT THIS TIME. THESE MAY ALWAYS BE REVISED AT A | | | LATER DATE. | | | | | | 3) NOTE: PLEASE SEE FBC 13-415.AB.1, .1.4 FOR EXTERIOR | | | LIGHTING CONTROLS. | | | | | | 4) NOTE: PLEASE INDICATE SIGN CIRCUIT PER 600.5 | | | | | | 5) NOTE: PLEASE SEE NFPA-96 FOR ANY SHUT DOWN OF | | | ELECTRICAL UNDER HOOD, NEW OR EXISTING? PANEL DOES NOT | | | INDICATE ANY SHUNT TYPE BREAKERS. | | | | | | 6) NOTE: PLEASE INDICATE NEW OR EXISTING WP GFI FOR A/C | | | EQUIPMENT LOCATIONS PER 210.63,210.8B3 | | | | | | | | | | | | ** IMPORTANT ** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2009-08-12 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-08-12 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-08-12 |
Time |
11:25 |
Sent To |
B |
|
| Notes |
| 2009-08-12 11:53:36 | *****APPROVED***** | | | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE | | | BEEN ADDRESSED; PLAN SHEETS WERE STAMPED, INITIALED, | | | AND DATED. | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2009-07-09 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-07-09 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-07-09 |
Time |
12:09 |
Sent To |
|
|
| Notes |
| 2009-07-09 12:42:47 | *****DENIED***** | | | | | | 1. STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241 - 2004 | | | EDITION. | | | | | | 2. EFFECTIVE 12/31/2008, THE 2006 EDITION OF NFPA 101, | | | LIFE SAFETY CODE, SHALL BE REFERENCED. AMEND REFERNCE | | | TO THE 2003 EDITION AS LISTED ON A1.0 AND E1 SHEETS. | | | | | | 3. ON THE EXTERIOR ELEVATION WHICH FRONTS SOUTH DIXIE | | | HIGHWAY, DISPLAY/SHOW THE BUILDING'S ADDRESS NUMBERS. | | | AS PER WEST PALM BEACH CODE, THE NUMBERS SHALL BE NO | | | LESS THAN 6" IN HEIGHT AND NO LESS THAN 1" IN | | | WIDTH/STROKE. | | | | | | 4. SHOW THE LOCATION OF RATED FIRE EXTINGUISHER(S) | | | WHICH SATISFY THE 75' TRAVEL DISTANCE. | | | | | | 5. ON SHEET A1.0, ELIMINATE REFERENCE TO NFPA 72 | | | (NATIONAL FIRE ALARM CODE) IF BUILDING ISN'T EQUIPPED | | | WITH A FIRE ALARM SYSTEM. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | SHEET INDICATING WHERE EACH ITEM WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2009-09-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-09-21 |
Time |
14:11 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-09-21 |
Time |
14:11 |
Sent To |
|
|
| Notes |
| 2009-09-21 14:11:49 | REVISION OK -- SHT P1. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2009-08-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-08-07 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-08-07 |
Time |
16:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2009-07-01 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-07-01 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-06-29 |
Time |
16:36 |
Sent To |
|
|
| Notes |
| 2009-07-01 13:07:33 | DENIED | | | REFERENCE: | | | FBC-2007 FUEL GAS | | | | | | A. THE FOLLOWING INFORMATION IS REQURIED FOR THE | | | SEPARATE GAS PERMIT: | | | | | | 1. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. -- PLANS SHOW 2 | | | PSI AT METER BUT NOTES INDICATED SIZED PER .5 PSI | | | TABLE. PLEASE CLARIFY. | | | | | | 2. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | | STANDARDS NFPA 54, NFPA 58, AND THE | | | FBC-2007 FUEL GAS CODE SEC 402.2 & RESIDENTIAL CODE | | | SEC. G2413.2. -- SUBMIT MANUF SHEETS FOR NEW TANKLESS | | | WATER HEATER. | | | | | | 3. PER SECTION 404.8 METALLIC PIPE EXPOSED TO CORROSIVE | | | ACTION, SUCH AS SOIL CONDITION OR MOISTURE, SHALL BE | | | PROTECTED IN AN APPROVED MANNER. GALVANIZED PIPE IS NOT | | | ALLOWED UNDERGROUND UNLESS PER SECTION 404.8.2 THE PIPE | | | PROTECTIVE COATINGS AND WRAPPINGS SHALL BE APPROVED FOR | | | THE APPLICATION AND SHALL BE FACTORY APPLIED. PLEASE | | | INDICATE METHOD OF PIPE PROTECTION. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2009-10-20 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-10-20 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-10-20 |
Time |
15:33 |
Sent To |
|
|
| Notes |
| 2009-10-20 15:35:37 | TO JIM'S DESK./WRT |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
|
Date |
2009-07-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-07-27 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-07-27 |
Time |
10:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2009-07-09 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-07-09 |
Time |
12:59 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-06-08 |
Time |
13:27 |
Sent To |
|
|
| Notes |
| 2009-06-08 13:27:50 | TO C32 |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
2 |
Status |
P |
Date |
2009-08-03 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-08-03 |
Time |
15:49 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-08-03 |
Time |
15:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
L |
LANDSCAPING |
| Rev No |
1 |
Status |
F |
Date |
2009-06-17 |
|
|
Cont ID |
|
| Sent By |
rkussner |
Date |
2009-06-17 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
rkussner |
Date |
2009-06-17 |
Time |
13:43 |
Sent To |
|
|
| Notes |
| 2009-06-17 15:38:45 | ***LANDSCAPE REVIEW FAILED*** | | | | | | PLEASE PROVIDE RESPONSES TO REVIEW COMMENTS IN WRITTEN | | | FORMAT. | | | | | | 1. PURSUANT TO SECTION 94-443 (C)(2), VEHICULAR USE | | | AREAS SHALL BE SCREENED FROM THOROUGHFARES AND | | | RESIDENTIAL USES AND DISTRICT BY A LANDSCAPE BUFFER AT | | | LEAST FIVE FEET IN WIDTH. TREES SHALL BE PLANTED AT | | | 30-FOOT INTERVALS AND HEDGES SHALL BE PLANTED AT | | | TWO-FOOT INTERVALS FOR EACH REQUIRED LANDSCAPE BUFFER. | | | THE WIDTH OF THE BUFFER ALONG THE EAST AND NORTH SIDES | | | OF THE SITE DO NOT MEET THIS REQUIREMENT. THE PARKING | | | STALL ON THE NORTH SIDE OF THE BUILDING COULD BE | | | LIMITED TO 18 FEET IN LENGTH WITH THE BALANCE OF THE | | | PAVEMENT BEING REMOVED AND THE AREA CONVERTED INTO | | | GREEN SPACE. THIS WILL REDUCE THE NONCONFORMITY. | | | | | | 2. PURSUANT TO SECTION 94-443 (C)(3), OFF-STREET | | | PARKING LOTS CONTAINING AT LEAST 12 INTERIOR PARKING | | | SPACES SHALL CONTAIN LANDSCAPE AREAS. THE TOTAL SIZE OF | | | SUCH LANDCAPED AREAS SHALL BE EQUAL TO TEN SQUARE FEET | | | FOR EACH PARKING SPACE AND SHALL BE PROVIDED WITHIN THE | | | INTERIOR OF AN OFF-STREET PAKRING AREA. LANDSCAPE AREAS | | | SHALL CONTAIN AT LEAST ONE SHADE OR FLOWERING TREE FOR | | | EACH 100 SQUARE FEET OF REQUIRED LANDSCAPED AREA. | | | | | | 3. A 5 X 24 FOOT TURNAROUND SHALL BE PROVIDED FOR | | | DEAD-END PARKING LOTS. THE WIDTH OF THE PARKING STALLS | | | COULD BE REDUCED TO 81/2 FEET IN WIDTH FROM 9 FEET TO | | | PICK UP SOME ADDITIONAL AREA. THE NEW PLANTER ON THE | | | NORTH END OF THE EAST PARKING ROW COULD BE REDUCED IN | | | WIDTH TO FIVE FEET. IF THE PARKING STALLS WERE REDUCED | | | IN WIDTH AS WELL AS THE LANDSCAPE ISLAND, AN ADDITIOANL | | | PARKING STALL COULD BE ADDED AND THERE WOULD BE ENOUGH | | | SPACE FOR THE TURN-AROUND. | | | | | | 4. A TYPICAL HANDICAP SPACE IS 12 FEET X 18 FEET WITH A | | | 5 FOOT X 18 FOOT MANEUVERING AREA. NO MANEURVEING AREA | | | HAS BEEN PROVIDED FOR THE HANDICAP SPACE. IF AN | | | ADDITIONAL SPACE IS ADDED TO THE EAST PARKING ROW, THEN | | | ONE SPACE COULD BE LOST ON THE WEST PARKING ROW TO | | | ALLOW FOR THE MANEUVERING ARE AND ADDTIONAL | | | LANDSCAPING. | | | | | | 5. THE NEW RAMP AND APRON ON THE EAST SIDE OF THE | | | BUILDING LIMITS THE REQUIRED 24 FOOT BACK-UP AREA TO 22 | | | FEET. THE 24 FEET MUST BE MAINTAINED. | | | | | | 6. THE DUMPSTER IS UNDERSIZED. BECAUSE IT MUST BE | | | REBUILT, IT SHOULD BE REBUILT TO CITY STANDARDS. ALSO, | | | THERE IS A GATE THAT CLOSES OFF THE PARKING LOT. HOW IS | | | THE DUMPSTER GOING TO BE ACCESSED IF THE GATE ON THE | | | PARKING LOT IS CLOSED? | | | | | | 7. THERE IS A UTILITY EASEMENT ALONG THE EAST AND SOUTH | | | SIDES OF THE PROPERTY. THE APPLICANT SHALL OBTAIN | | | WRITTEN AUTHORZATION FROM THE EASEMENT HOLDER TO PLANT | | | WITHIN THOSE EASEMENTS. | | | | | | 8. ALL PROHIBITED PLANT SPECIES SHALL BE REMOVED FROM | | | THE SITE, INCLUDING THE RIGHT-OF-WAY AND THE CANAL | | | EMBANKMENT. THE CANAL BANK SHALL BE STRIPPED OF TREES | | | AND SHRUBS WITH SOD AND IRRIGATION INSTALLED. | | | | | | 9. PLEASE PROVIDE A CROSS-SECTION OF THE SLOPE WITH | | | LANDSCAPING AND IMPROVEMENTS SHOWN FROM THE PARKING LOT | | | TO THE WATER'S EDGE OF THE CANAL. | | | | | | 10. PURSUANT TO SECTION 94-443 (C)(5)(A), LANDSCAPE | | | AREAS SHALL BE SEPARATED FROM VEHICULAR USE AREAS BY | | | NONMOUNTABLE, CONCRETE CURBING OF THE TYPE | | | CHARACTERIZED AS "TYPE D". | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT | | | KUSSNER @ (561) 822-1462. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2009-11-02 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-11-02 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-11-02 |
Time |
14:55 |
Sent To |
|
|
| Notes |
| 2009-11-02 14:56:40 | REVISION OK -- SHT P1. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2009-09-21 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-09-21 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-09-21 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2009-09-21 14:12:19 | REVISION OK -- SHT P1. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2009-08-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-08-07 |
Time |
16:49 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-08-07 |
Time |
16:49 |
Sent To |
|
|
| Notes |
| 2009-08-07 16:50:07 | A LICENSED PLUMBING CONTRACTOR IS REQUIRED TO INSTALL | | | THE BACKFLOW FOR THE IRRIGATION. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2009-07-01 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-07-01 |
Time |
13:08 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-06-29 |
Time |
16:37 |
Sent To |
|
|
| Notes |
| 2009-07-01 13:19:04 | DENIED | | | REFERENCE: | | | FBC-2007 PLUMBING | | | FBC-2007 CHAPTER 1 | | | | | | 1. SHT P1 THE WATER ISOMETRIC RISER DIAGRAM DOES NOT | | | REFLECT THE FLOOR PLAN. THE FLOOR PLAN SHOWS ONLY COLD | | | WATER TO THE MOP SINK AND THE HOSE BIBB LINE CONNECTING | | | BY THE ICE MAKER. SECTION 106.1.1 PLEASE CORRELATE. -- | | | ALSO THE HOSE BIBB REQUIRES A SHUT OFF VALVE ON THE | | | SUPPLY LINE TO THE HOSE BIBB. SECTION 606.2(2). | | | | | | 2. SHT P1 SANITARY RISER DIAGRAM DOES NOT REFLECT THE | | | FLOOR PLAN FOR THE FLOOR DRAIN DOWNSTREAM OF THE MOP | | | SINK. PLEASE CORRELATE. SECTION 106.1.1. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2009-08-03 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2009-08-03 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2009-08-03 |
Time |
09:11 |
Sent To |
|
|
| Notes |
| 2009-08-03 09:14:00 | ***PROVISO*** | | | | | | TYPE D CURBING SHALL BE INSTALLED AS NOTED ON THE SITE | | | PLAN BY YELLOW HIGHLIGHTS. | | | | | | PLEASE CONTACT KELLY FREEMAN, PLANNER, 561-822-1435 OR | | | [email protected] WITH QUESTIONS. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2009-06-18 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2009-06-18 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2009-06-18 |
Time |
08:59 |
Sent To |
|
|
| Notes |
| 2009-06-18 10:25:43 | ***FAILED*** | | | | | | 1. WAS THE SIGN AT THE NW CORNER OF THE SITE | | | CONSTRUCTED WITH A PERMIT? IF SO, IT MAY REMAIN, IF | | | NOT, IT SHALL BE RELOCATED TO COMPLY WITH THE | | | REQUIREMENTS OF SEC. 94-408(A)(2). | | | | | | 2. ARE THE AWNING AREAS BEING REDUCED ALONG WITH THE | | | DECK AREAS? THE PLANS ARE UNCLEAR IN THAT RESPECT. THE | | | SITE PLAN DOES NOT INDICATE THE MAXIMUM EXTENT OF THE | | | AWNINGS AND THE DEMOLITION PLAN IS NOT SPECIFIC AS TO | | | WHAT WILL HAPPEN TO THEM BEYOND REFURBISHMENT. PLEASE | | | NOTE THAT AWNINGS MAY NOT ENCROACH MORE THAN FOUR FEET | | | INTO A REQUIRED SETBACK AND BE SUPPORTED BY MEANS OTHER | | | THAN ATTACHMENT TO A BUILDING. | | | | | | 3. THE EXISTING DUMPSTER ENCLOSURE DOES NOT MEET THE | | | MINIMUM DIMENSIONAL REQUIREMENTS. UNLESS APPROVED TO | | | REMAIN BY ENGINEERING SERVICES, IT SHOULD BE REPLACED | | | WITH A CODE-COMPLIANT DUMPSTER ENCLOSURE IF SPACE | | | EXISTS FOR IT TO BE ACCOMODATED. I'VE ATTACHED A | | | DIAGRAM TO THE HARD COPY OF THESE COMMENTS FOR YOUR | | | USE. | | | | | | 4. THE PROPOSED ON-STREET LOADING ZONE DOES NOT MEET | | | THE MINIMUM DIMENSIONAL REQUIREMENTS OF 10 FEET BY 20 | | | FEET. IT SHOULD BE REMOVED FROM THE PLAN. | | | | | | PLEASE CONTACT KELLY FREEMAN, PLANNER, AT 561-822-1458 | | | OR [email protected] QUESTIONS OR COMMENTS. |
|
|