| 2009-06-05 15:41:17 | ****CORRECTIONS**** |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | FBC FLORIDA BUILDING CODE 2004 |
| | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL |
| | |
| | 1. FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED |
| | FAC9B72. LOCAL PRODUCT APPROVAL APPLICATION AVAILABLE |
| | AT WWW.FLORIDABUILDING.ORG OR HTTP://WWW.WPB.ORG/CONSTR |
| | UCTION/PDF/PRODUCT%20APPROVAL.PDF. PLEASE COMPLETE THE |
| | APPLICATION WITH ALL PERTINENT INFORMATION, INCLUDING |
| | HOW QUALITY ASSURANCE WILL BE ADDRESSED (A LETTER FROM |
| | THE ENGINEER STATING THAT SHE WILL DO AN INSPECTION IS |
| | ONE METHOD OF ADDRESSING QUALITY ASSURANCE). |
| | |
| | 2. PROVIDE A CONTRACT FOR THIS JOB. VALUE IS TO INCLUDE |
| | LABOR AND MATERIALS. FBC*108. |
| | |
| | 3. PLEASE CLARIFY DESIGN CRITERIA. IF THIS IS |
| | ASSOCIATED WITH THE MASTER PERMIT AS NOTED ON THE |
| | APPLICATION, AND WAS SHOWN ON THE PLANS FOR 08010413, |
| | THEN THE DESIGN CRITERIA SHOULD BE FBC2004 AND ASCE7-02 |
| | AND REVIEW BY DESIGNER OF RECORD IS REQUIRED FBC*103. |
| | IF THIS IS A STAND-ALONE PERMIT INDEPENDENT OF |
| | 08010413, THEN THE DESIGN CRITERIA IS FBC2007 WITH 2009 |
| | SUPPLEMENTS AND ASCE7-05. ENGINEER HAS STATED FBC2004 |
| | AND ASCE7-05 AS DESIGN CRITERIA; NOT CONSISTENT. |
| | |
| | 4. IF ASCE7-05 IS USED AS DESIGN CRITERIA, PLEASE |
| | PROVIDE JUSTIFICATION FOR EXPOSURE B PRESSURES. THIS |
| | PARCEL APPEARS TO BE WITHIN 1500' OF EXPOSURE C |
| | ROUGHNESS CONDITIONS (INTRACOASTAL). |
| | |
| | |
| | |
| | |
| | |
| | |