Plan Review Details - Permit 09060079
| Plan Review Stops For Permit 09060079 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2009-07-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-07-16 |
Time |
08:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-07-16 |
Time |
08:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2009-06-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-06-10 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-06-10 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2009-06-10 16:46:07 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2007 | | | FBC EB FLORIDA BUILDING CODE 2007 EXISTING BUILDING | | | CODE | | | FBC R FLORIDA BUILDING CODE 2007 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2007 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FS FLORIDA STATUTE | | | | | | 1. FBC3202.3.1, PROVIDE A SITE PLAN AND SHOW AWNING IN | | | RELATION TO PROPERTY LINE AND SIDEWALK. | | | | | | FOR YOUR CONVENIENCE: | | | | | | 3202.3 ENCROACHMENTS 8 FEET OR MORE ABOVE GRADE. | | | ENCROACHMENTS 8 FEET (2438 MM) OR MORE ABOVE GRADE | | | SHALL COMPLY WITH SECTIONS 3202.3.1 THROUGH 3202.3.4. | | | | | | 3202.3.1 AWNINGS, CANOPIES, MARQUEES AND SIGNS. | | | AWNINGS, CANOPIES, MARQUEES AND SIGNS SHALL BE | | | CONSTRUCTED SO AS TO SUPPORT APPLICABLE LOADS AS | | | SPECIFIED IN CHAPTER 16. AWNINGS, CANOPIES, MARQUEES | | | AND SIGNS WITH LESS THAN 15 FEET (4572 MM) CLEARANCE | | | ABOVE THE SIDEWALK SHALL NOT EXTEND INTO OR OCCUPY MORE | | | THAN TWO-THIRDS THE WIDTH OF THE SIDEWALK MEASURED FROM | | | THE BUILDING. STANCHIONS OR COLUMNS THAT SUPPORT | | | AWNINGS, CANOPIES, MARQUEES AND SIGNS SHALL BE LOCATED | | | NOT LESS THAN 2 FEET (610 MM) IN FROM THE CURB LINE. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2009-06-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-06-22 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-06-22 |
Time |
09:44 |
Sent To |
|
|
| Notes |
| 2009-06-22 09:44:56 | SENT TO ZONING |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2009-06-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2009-06-10 |
Time |
16:48 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-06-03 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2009-06-04 13:38:12 | TO ZONING |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2009-06-23 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2009-06-23 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2009-06-23 |
Time |
15:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2009-06-09 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2009-06-09 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2009-06-09 |
Time |
10:40 |
Sent To |
|
|
| Notes |
| 2009-06-09 10:43:17 | ZONING REVIEW: FAILED | | | | | | 1) PLEASE ATTACHED COPIES OF BUILDING ELEVATIONS | | | INDICATING LOCATION AND PLACEMENT OF AWNINGS. | | | | | | 2) PLEASE INDICATED IN AWNING SECTION LOCATION OF | | | PROPERTY LINES FOR BOTH EAST AND SOUTH ELEVATIONS. IT | | | APPEARS THESE WILL OVERHANG INTO THE RIGHT-OF-WAY. | | | PLEASE CONFIRM. | | | | | | 3) PLEASE INDICATE WHETHER THESE AWNINGS WILL BE | | | REPLACING THE AWNINGS THAT WERE PREVIOUSLY ON BUILDING, | | | AND WHETHER THEY ARE DIFFERENT IN SIZE (HEIGHT/DEPTH). | | | | | | MATT FLIS - 822-1445 |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |