Plan Review Details - Permit 09060049
| Plan Review Stops For Permit 09060049 |
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2009-07-01 |
|
|
Cont ID |
|
| Sent By |
dwise |
Date |
2009-07-01 |
Time |
21:04 |
Rev Time |
0.00 |
| Received By |
dwise |
Date |
2009-07-01 |
Time |
21:04 |
Sent To |
PC |
|
| Notes |
| 2009-07-01 21:05:08 | SUBMITTED CLARIFICATION LETTER REGARDING WIND LOAD | | | DESIGN PARAMETERS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2009-06-22 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-06-22 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-06-22 |
Time |
14:31 |
Sent To |
PC |
|
| Notes |
| 2009-06-22 14:32:37 | **PROVISO** | | | REVISE PAGE 2 ON PLANS TO REFLECT WIND LOAD | | | CALCULATIONS WHICH ARE BASED ON ASCE7-05 IN ACCORDANCE | | | WITH FBC-M 301.12. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2009-06-09 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-06-09 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-06-09 |
Time |
09:37 |
Sent To |
PC |
|
| Notes |
| 2009-06-09 09:48:53 | REVIEW #: 1ST | | | ACTION: DENIED | | | | | | FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | 1. EXHAUST FAN, DUCTWORK AND CURB SHALL BE DESIGNED AND | | | INSTALLED FOR WIND RESISTANCE IN ACCORDANCE WITH FBC-M | | | 301.12. PROVIDE MANUFACTURER'S DATA SHOWING THE FAN IS | | | DESIGNED FOR WIND RESISTANCE. PROVIDE DETAIL FOR | | | ATTACHMENT OF ROOF CURB TO BUILDING STRUCTURE, FAN TO | | | ROOF CURB AND SUPPORT OF DUCT TO BUILDING STRUCTURE FOR | | | WIND RESISTANCE. | | | | | | 2. PLANS INDICATE THIS IS A VENTILATION SYSTEM FOR A | | | GAS OVEN. WHERE APPLIANCES ARE VENTED THROUGH A | | | VENTILATING HOOD OR EXHAUST SYSTEM EQUIPPED WITH A | | | POWER MEANS OF EXHAUST, PROVISIONS SHALL BE MADE TO | | | ALLOW THE FLOW OF GAS TO THE MAIN BURNERS ONLY WHEN THE | | | POWER MEANS OF EXHAUST IS IN OPERATION IN ACCORDANCE | | | WITH FBC-FG 503.3.4. SHOW MEANS OF INTERCONNECTION | | | BETWEEN GAS SUPPLY AND EXHAUST FAN. | | | | | | 3. PROVIDE "AIRFLOW SPECIALISTS, INC." CETTIFICATE OF | | | AUTHORIZATION NUMBER IN THE ENGINEERING BUSINESS TITLE | | | BLOCK IN ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODE | | | RULE 61G15-23.002. | | | | | | 4. SEPARATE ELECTRICAL PERMIT REQUIRED TO PROVIDE POWER | | | AND CONTROLS FOR THIS VENTILATION SYSTEM. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
|