| Plan Review Stops For Permit 09060023 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2010-03-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2010-03-30 |
Time |
09:07 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2010-03-30 |
Time |
09:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2010-01-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2010-01-26 |
Time |
11:59 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
2010-01-26 |
Time |
11:33 |
Sent To |
|
|
| Notes |
| 2010-01-26 14:58:31 | BUILDING PLAN REVIEW | | | PERMIT: 09060023 | | | ADD: 1009 BANYAN BLVD | | | CONT: TO BE DETERMINED | | | TEL: (561)659-2383 | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2ND REVIEW | | | ACTION: DENIED | | | JAN. 26/2010 | | | | | | PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER | | | MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC | | | BUILDING WITH 2009 | | | | | | | | | 1) COMPLIED. | | | | | | 1A) 1603.1.4 WIND DESIGN DATA. | | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | | DESIGN OF THE LATERAL-FORCE-RESISTING SYSTEM OF THE | | | BUILDING: | | | 1.1. COMPLIED. BASIC WIND SPEED (3-SECOND GUST), MILES | | | PER HOUR (KM/HR). | | | | | | 1.2. 2ND REQUEST, WIND IMPORTANCE FACTOR, I W , AND | | | BUILDING CLASSIFICATION FROM TABLE 1604.5 OR TABLE 6-1, | | | ASCE 7 AND BUILDING CLASSIFICATION IN TABLE 1-1, ASCE | | | 7. | | | PLEASE REVIEW THE BUILDING CATEGORIES, THIS BUILDING IS | | | PART OF THE WATER DISTRIBUTION SYSTEM MAKING THIS A | | | BUILDING CATEGORY IV OR A 1.15 IMPORTANCE FACTOR (TABLE | | | 6-1). | | | | | | 1.3. COMPLIED. WIND EXPOSURE, IF MORE THAN ONE WIND | | | EXPOSURE IS UTILIZED, THE WIND EXPOSURE AND APPLICABLE | | | WIND DIRECTION SHALL BE INDICATED. | | | | | | 1.4.COMPLIED. THE APPLICABLE ENCLOSURE CLASSIFICATIONS | | | AND, IF DESIGNING WITH ASCE 7, INTERNAL PRESSURE | | | COEFFICIENT. | | | | | | 1.5. WITH THE 1.15 IMPORTANCE FACTOR THE STATED | | | PRESSURES WILL BE LOW. COMPONENTS AND CLADDING. THE | | | DESIGN WIND PRESSURES IN TERMS OF PSF (KN/M 2 ) TO BE | | | USED FOR THE SELECTION OF EXTERIOR COMPONENTS AND | | | CLADDING MATERIALS NOT SPECIFICALLY | | | DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL. | | | | | | 1B)PATIALLY COMPLIED. WITH THE NEW WIND PRESSURE | | | COEFFICIENT PRESSURES WILL NEED TO BE REVIEWED WITH THE | | | HIGHER PRESSURES. PROVIDE DOCUMENTATION ON THE WIND | | | RESISTANT CURB. COMPONENTS AND CLADDING.1603.1.4(5). | | | | | | 2)) 2ND REQUEST, SHEET M-5 ALSO INDICATES THAT VARIOUS | | | EXHAUST DUCTWORK IS BEING DELETED FROM PENETRTING THE | | | ROOF, PLANS INDICATE TO PATCH HOLE,. THE RESPONSE | | | INDICATES SHEET A1.01 DETAIL 1 WILL LEAVE THE CURBING. | | | THE MECHANICAL PLANS MAKES ONE TO THINK THE CURB IS TO | | | BE REMOVED! TO PATCH HOLE. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | SURVEY: | | | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2009-06-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-06-18 |
Time |
16:20 |
Rev Time |
0.50 |
| Received By |
jwitmer |
Date |
2009-06-18 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2009-06-18 16:18:00 | BUILDING PLAN REVIEW | | | PERMIT: 09060023 | | | ADD: 1009 BANYAN BLVD | | | CONT: TO BE DETERMINED | | | TEL: (561)659-2383 | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER | | | MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC | | | BUILDING WITH 2009 | | | | | | | | | 1) SHEET M-5 ROOF TOP UNITS, NOTES INDICATES THAT A | | | STRUCTURAL ENGINEER WILL BE EMPLOYED TO VERIFY ROOF | | | LOAD CAPACITY AND PROVIDE STRUCTURAL DETAILS FOR | | | ADAPTION OF EXISTING ROOF OPENINGS FOR THE NEW ROOF | | | CURBS. 106.1.2 ADDITIONAL INFORMATION REQUIRED. | | | | | | 1A) 1603.1.4 WIND DESIGN DATA. | | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | | DESIGN OF THE LATERAL-FORCE-RESISTING SYSTEM OF THE | | | BUILDING: | | | 1. BASIC WIND SPEED (3-SECOND GUST), MILES PER HOUR | | | (KM/HR). | | | | | | 2. WIND IMPORTANCE FACTOR, I W , AND BUILDING | | | CLASSIFICATION FROM TABLE 1604.5 OR TABLE 6-1, ASCE 7 | | | AND BUILDING CLASSIFICATION IN TABLE 1-1, ASCE 7. | | | | | | 3. WIND EXPOSURE, IF MORE THAN ONE WIND EXPOSURE IS | | | UTILIZED, THE WIND EXPOSURE AND APPLICABLE WIND | | | DIRECTION SHALL BE INDICATED. | | | | | | 4. THE APPLICABLE ENCLOSURE CLASSIFICATIONS AND, IF | | | DESIGNING WITH ASCE 7, INTERNAL PRESSURE COEFFICIENT. | | | | | | 5. COMPONENTS AND CLADDING. THE DESIGN WIND PRESSURES | | | IN TERMS OF PSF (KN/M 2 ) TO BE USED FOR THE SELECTION | | | OF EXTERIOR COMPONENTS AND CLADDING MATERIALS NOT | | | SPECIFICALLY | | | DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL. | | | | | | 1B) PROVIDE DOCUMENTATION ON THE WIND RESISTANT CURB. | | | COMPONENTS AND CLADDING.1603.1.4(5). | | | | | | 2)) SHEET M-5 ALSO INDICATES THAT VARIOUS EXHAUST | | | DUCTWORK IS BEING DELETED FROM PENETRTING THE ROOF, | | | PLANS INDICATE TO PATCH HOLE, PLEASE PROVIDE DETAILS AS | | | TO HOW THIS WILL HAPPEN. | | | 106.1.2 ADDITIONAL INFORMATION REQUIRED, COMPONENTS AND | | | CLADDING. | | | | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)805-6731 | | | E-MAIL: [email protected] | | | SURVEY: | | | WWW.SURVEYMONKEY.COM/WESTPALMBEACHCONSTRUCTIONSERVICES | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2010-02-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2010-02-01 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2010-02-01 |
Time |
16:44 |
Sent To |
|
|
| Notes |
| 2010-02-01 16:44:43 | REDLINED 2008 NEC AS THIS WAS APPLIED FOR PERMIT AFTER | | | OCTOBER 1ST, 2009 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2009-06-19 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-06-19 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-06-19 |
Time |
14:39 |
Sent To |
|
|
| Notes |
| 2009-06-19 14:39:19 | | | | | | | | | | | | | ** DENIED PLANS * | | | | | | 1) NOTE: NO LICENSED CONTRACTOR HAS APPLIED FOR THE | | | SCOPE OF WORK UNDER PERMIT APPLICATION. PLANS SUBMITTED | | | AS A PLAN REVIEW ONLY. | | | PLEASE BE AWARE OF POSSIBLE CODE CHANGES. | | | | | | | | | 2) NOTE: PLEASE CLARIFY SCOPE OF WORK. THE PLANS | | | SUBMITTED DO NOT INDICATE ANY WORK FOR ELECTRICAL | | | EXCEPT FOR SOME NEW A/C UNITS AND WIRING. | | | HOWEVER BASED ON THE PRESCRIPTIVE * METHOD B* | | | SUBMITTED, THERE IS GOING TO BE NEW LIGHTING IN SEVERAL | | | AREAS. | | | PLEASE PROVIDE INFORMATION AS A REVIEW CAN NOT BE DONE | | | AT THIS TIME AS NO NEW LIGHTING IS SHOWN ON PLANS. | | | PLEASE ALSO BE AWARE OF LIGHTING CONTROLS IF NEW. | | | 13-415.AB.5, 13-415.AB.1.1,.1.2, .1.3, .1.4. | | | | | | 3) NOTE: PLEASE SEE FAC 69A-60.003,.004 AS THE NFPA-101 | | | AND NFPA-1 AS OF DECEMBER 31ST 2008 IS NOW THE 2006 | | | EDITION. PLANS STATE 2003. | | | PLEASE ALSO BE AWARE OF THE 2009 REVISIONS/GLITCH | | | AMENDMENTS TO THE 2007 FBC. | | | POSSIBLE 2008 NEC MAY BE ADOPTED IN THE NEAR FUTURE. | | | ALL PERMIT APPLICATIONS MUST BE MADE PRIOR TO | | | IMPLEMENTATION DATE OR MUST BE UNDER THE 2008 NEC. | | | | | | | | | ** IMPORTANT ** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2010-04-06 |
|
|
Cont ID |
|
| Sent By |
mcarsill |
Date |
2010-04-06 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
mcarsill |
Date |
2010-04-06 |
Time |
09:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2010-02-09 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2010-02-09 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2010-02-09 |
Time |
12:13 |
Sent To |
|
|
| Notes |
| 2010-02-09 12:17:57 | *****DENIED***** | | | | | | THE FOLOWING COMMENTS TAKEN FROM THE PREVIOUS FIRE | | | REVIEW STILL NEED TO BE ADDRESSED: | | | | | | 1. THE PROJECT SITE ADDRESS SHALL BE IN THE TITLE BLOCK | | | OF EACH SUBMITTED PLAN SHEET. ONLY NEWLY ADDED SHEET | | | A-101 WAS CORRECTED | | | | | | 2. PROVIDE SEQUENCE OF OPERATION UPON ACTIVATION OF THE | | | SMOKE (DUCT) DETECTOR. AS PER WEST PALM BEACH FIRE | | | PREVENTION, DUCT SMOKE DETECTOR(S) SHALL INITIATE A | | | GENERAL FIRE ALARM - IN ADDITION TO FAN SHUT DOWN. | | | ADRRESS COMMENT | | | | | | 3. ON SHEET E-2.01, AMEND GENERAL ELECTRICAL NOTE #1 TO | | | REFLECT THE 2006 (INSTEAD OF 2003) EDITION OF NFPA 101 | | | IS TO BE REFERENCED. ADDRESS COMMENT. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING WHERE EACH COMMENT WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2009-06-26 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-06-26 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-06-26 |
Time |
10:16 |
Sent To |
|
|
| Notes |
| 2009-06-26 10:42:35 | *****DENIED***** | | | | | | 1. THE PROJECT SITE ADDRESS SHALL BE IN THE TITLE BLOCK | | | OF EACH SUBMITTED PLAN SHEET. | | | | | | 2. PROVIDE SEQUENCE OF OPERATION UPON ACTIVATION OF THE | | | SMOKE (DUCT) DETECTOR. AS PER WEST PALM BEACH FIRE | | | PREVENTION, DUCT SMOKE DETECTOR(S) SHALL INITIATE A | | | GENERAL FIRE ALARM - IN ADDITION TO FANN SHUT DOWN. | | | | | | 3. ON SHEET E-2.01, AMEND GENERAL ELECTRICAL NOTE #1 TO | | | REFLECT THE 2006 (INSTEAD OF 2003) EDITION OF NFPA 101 | | | IS TO BE REFERENCED. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING WHERE EACH COMMENT WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2010-03-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2010-03-16 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2010-03-16 |
Time |
09:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2010-02-01 |
Time |
|
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2010-01-19 |
Time |
08:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2009-06-26 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-06-26 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-06-02 |
Time |
10:32 |
Sent To |
|
|
| Notes |
| 2009-06-02 10:21:57 | COMM BOARD #17 | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2010-04-16 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2010-04-16 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2010-04-16 |
Time |
15:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2010-02-01 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2010-02-01 |
Time |
11:38 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2010-02-01 |
Time |
11:38 |
Sent To |
|
|
| Notes |
| 2010-02-01 11:38:38 | WIND RESISTANCE DATA PROVIDED. THIS PROVISO HAS BEEN | | | ADDRESSED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2009-06-19 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-06-19 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-06-19 |
Time |
08:52 |
Sent To |
|
|
| Notes |
| 2009-06-19 08:54:36 | REVIEW TO REMAIN IN FAIL STATUS PENDING RECEIPT OF | | | PERMIT APPLICATION FROM CONTRACTOR. | | | | | | **PROVISO** | | | PROVIDE MANUFACTURER'S DATA FOR WIND RESISTANCE OF | | | CONDENSING UNIT. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2009-06-09 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2009-06-09 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2009-06-09 |
Time |
15:16 |
Sent To |
|
|
| Notes |
|
|