| Plan Review Stops For Permit 09060009 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2009-11-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-11-16 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-11-16 |
Time |
11:25 |
Sent To |
|
|
| Notes |
| 2009-11-16 11:25:42 | ENERGY CALCS AND LINTEL PRODUCT APPROVAL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2009-09-21 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-09-21 |
Time |
14:20 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-09-21 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2009-09-21 14:21:40 | MET WITH MICHAEL PANCZAK. NEED TO RESUBMIT THE ENERGY | | | CALCULATIONS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2009-09-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-09-16 |
Time |
11:57 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-09-16 |
Time |
11:56 |
Sent To |
|
|
| Notes |
| 2009-09-16 12:02:49 | REVISION PACKAGE CHECKLIST: | | | | | | 1- PRECAST LINTEL PRODUCT APPROVAL NOA 08-0320.09 | | | SUBMITTED IS FOR 4", 6" AND 12" PRECAST LINTELS. NEED | | | TO PROVIDE PRODUCT APPROVAL FOR 8" PRECAST LINTELS AS | | | SHOWN ON PLANS. (REPEAT COMMENT). | | | ***REMAINDER: ENGINER OF RECORD TO REVIEW AND APPROVE | | | IN WRITING ALL PRODUCT APPROVALS AS REQUIRED BY SEC. | | | 106.3.3 CITY AMENDMENTS TO FBC. | | | | | | 2- ENERGY CALCULATIONS SUBMITTED: | | | A) ENERGY CALCULATIONS PREPARER TO SIGN AND DATE BOTTOM | | | OF FORM. | | | | | | B) OWNER/AGENT TO SIGN AND DATE BOTTOM OF FORM. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2009-08-19 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-08-19 |
Time |
15:27 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-08-19 |
Time |
14:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2009-07-30 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-07-30 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-07-30 |
Time |
11:03 |
Sent To |
|
|
| Notes |
| 2009-07-30 11:18:02 | RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW SECOND | | | CHECKLIST. | | | 2007 FL. RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | | | 1- PROVIDE RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13 | | | FLORIDA STATUTE. | | | ***NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK | | | UP. | | | | | | 2- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | | N1100.0 OF 2007 FLORIDA RESIDENTIAL CODE. (REPEAT | | | COMMENT. NOT ADDRESSED AT ALL. THIS IS REQUIRED PRIOR | | | TO RECEIVE THE PERMIT. SEE SEC. N1100.2.2 OF 2007 | | | FLORIDA RESIDENTIAL CODE). | | | | | | 3- PROVIDE 2 COPIES OF PRODUCT APPROVALS AS REQUIRED BY | | | DCA RULE 9B-72 FOR: | | | A) PRECAST LINTELS AS SHOWN ON PLANS. (REPEAT COMMENT. | | | NOT ADDRESSED AT ALL). | | | | | | B) ) SIMPSON STRUCTURAL CONNECTORS AS SPECIFIED ON | | | PLANS AND DETAILS. (REPEAT COMMENT. NOT ADDRESSED AT | | | ALL). | | | | | | 4- SHEET 3.1: | | | A) REVISE EGRESS WINDOWS NOTE: SEE SEC. R310 OF 2007 | | | FLORIDA RESIDENTIAL CODE FOR CORRECT MIN. OPENING | | | HEIGHT AND CORRECT MIN. NET CLEAR OPENING. (REPEAT | | | COMMENT. NOT PROPERLY ADDRESSED. EGRESS WINDOW OPENING | | | IS NOT MEASURED BY THE MIN. TOTAL GLASS AREA BUT BY THE | | | MIN. TOTAL OPENING AREA. ALSO, CLARIFY WHERE IS THE | | | MIN. CLEAR OPENING HEIGHT OF 31" AND MIN. CLEAR OPENING | | | WIDTH OF 36" TAKEN FROM. ALSO, THE LAST SENTENCE THAT | | | "THE NET CLEAR OPENING SHALL IN NO CASE BE LESS THAN 5 | | | SQ.FT" . IS INCORRECT. THIS OPENING APPLIES TO GROUND | | | UNITS ONLY. SEE SEC R310 OF 2007 FLORIDA RESIDENTIAL | | | CODE AND REVISE INFORMATION AS REQUIRED. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2009-06-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-06-16 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-06-16 |
Time |
11:51 |
Sent To |
|
|
| Notes |
| 2009-06-16 11:52:52 | RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW CHECKLIST. | | | 2007 FL. RESIDENTIAL CODE WITH 2009 REVISIONS. | | | | | | 1- PROVIDE RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13 | | | FLORIDA STATUTE. | | | ***NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK | | | UP. | | | | | | 2- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC. | | | N1100.0 OF 2007 FLORIDA RESIDENTIAL CODE. | | | | | | 3- PROVIDE 2 COPIES OF PRODUCT APPROVALS AS REQUIRED BY | | | DCA RULE 9B-72 FOR: | | | A) FRENCH DOORS INCLUDING FRENCH DOORS WITH SIDELITES | | | AS SHOWN ON PLANS. | | | | | | B) FIXED WINDOWS AS SHOWN ON PLANS. | | | | | | C) SINGLE HUNG WINDOWS AS SHOWN ON PLANS. | | | | | | D) WINDOW MULLIONS AS SHOWN ON PLANS. AND, CLEARLY MARK | | | ON DRAWINGS SPECIFIC MULLION SIZE AND ANCHORS TO VERIFY | | | COMPLIANCE WITH THE CALCULATED DESIGN PRESSURES. SEC. | | | R301. | | | | | | E) SHUTTERS IF DOORS AND WINDOWS DON'T HAVE IMPACT | | | GLAZING. AND PROVIDE COMPLETE INSTALLATION SCHEDULE. | | | SEE ATTACHED SAMPLE. IN ADDITION MARK ON DRAWINGS | | | SHUTTERS MOUNTING CONDITIONS AND ANCHOR TYPE AND | | | SPACING TO BE USED. | | | | | | F) PRECAST LINTELS AS SHOWN ON PLANS. | | | | | | G) SIMPSON STRUCTURAL CONNECTORS AS SPECIFIED ON PLANS | | | AND DETAILS. | | | | | | 4- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC. | | | | | | 5- SHEET 3.1: | | | A) SPECIFY SAFETY GLASS FOR WINDOW ON SHOWER OF MASTER | | | BATHROOM AND WINDOWS NEXT TO SWING DOOR IN MASTER | | | BEDROOM. SEC. R308.4 2007 FLORIDA RESIDENTIAL CODE. | | | | | | B) REVISE EGRESS WINDOWS NOTE: SEE SEC. R310 OF 2007 | | | FLORIDA RESIDENTIAL CODE FOR CORRECT MIN. OPENING | | | HEIGHT AND CORRECT MIN. NET CLEAR OPENING. | | | | | | C) INFORMATION ON WIND DESIGN INFORMATION AND DESIGN | | | PARAMETERS DON'T CORRESPOND TO EACH OTHER. ONE CALLS | | | FOR BUILDING EXPOSURE "C", WHILE THE OTHER ONE CALLS | | | FOR BUILDING EXPOSURE "B". REVISE AS REQUIRED TO MATCH. | | | (NOTE: ACCORDING TO 2009 REVISIONS, BUILDING IS LOCATED | | | ON EXPOSURE "C"). | | | | | | D) REVISE CODE SECTIONS SPECIFIED ON WIND DESIGN | | | INFORMATION AND DESIGN PARAMETERS INFORMATION. SEE FBC | | | 2007 FOR CORRECT SECTION TO BE REFERENCED AND REVISE AS | | | REQUIRED. | | | | | | E) FRAMED WALLS REQUIRES TWO LAYERS OF WATER RESISTANT | | | BARRIERS AS REQUIRED BY SEC. R703.6.3 OF 2007 FLORIDA | | | RESIDENTIAL CODE. REVISE GENERAL WALL LEGEND AS | | | REQUIRED. | | | | | | F) SPECIFY MIN. STUCCO THICKNESS (7/8") AS REQUIRED BY | | | TABLE R702.1(1) OF 2007 FLORIDA RESIDENTIAL CODE. | | | REVISE GENERAL WALL LEGEND AS REQUIRED. | | | | | | G) CLARIFY WHY THERE IS A NOTE THAT IMPACT RESISTANT | | | WINDOWS REQUIRE 2X BUCKS. SEE WINDOW PRODUCT APPROVAL | | | AND REVISE/CLARIFY AS REQUIRED. | | | | | | 6- SHEET 4.1: | | | A) REVISE TYPICAL DOOR JAMB DETAIL. 2X4 STRUCTURAL BUCK | | | SIZE DOESN'T PROVIDE FULL SUPPORT TO THE DOOR FRAME AS | | | REQUIRED BY SEC. R613.6 OF 2007 FLORIDA RESIDENTIAL | | | CODE. SEE DOOR PRODUCT APPROVAL FOR SIZE OF FRAME AND | | | SPECIFIED CORRECT STRUCTURAL BUCK SIZE. | | | | | | B) TYP. WOOD WALL SECTION: SPECIFY 2 LAYERS OF WATER | | | RESISTANT BARRIER (SEC. R703.6.3) AND MIN. STUCCO | | | THICKNESS (TABLE R702.1(1). | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
P |
Date |
2009-11-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2009-11-16 |
Time |
09:22 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2009-11-16 |
Time |
09:02 |
Sent To |
P |
|
| Notes |
| 2009-11-16 09:23:13 | TO KEN STEVENS./WRT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2009-09-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-09-17 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-09-17 |
Time |
14:17 |
Sent To |
|
|
| Notes |
| 2009-09-17 14:17:47 | PLANS SIGNED, | | | | | | REDLINED 13-606.AB.1.2.4 FOR TYPES OF RECESSED LIGHTS |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
F |
Date |
2009-09-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-09-17 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-09-17 |
Time |
09:05 |
Sent To |
|
|
| Notes |
| 2009-09-17 09:05:52 | | | | ** DENIED PLANS TEMPORARILY** | | | | | | | | | 1) NOTE: PLEASE SEE FS 471.003,481.229, WHEN MEETING | | | EXCEPTIONS, DESIGN PROFESSIONAL LICENSED UNDER FS 489 | | | SHALL PRINT NAME AND SIGN PLANS. | | | ** A CALLED WAS PLACED TO GC AND LEFT MESSAGE FOR | | | ELECTRICAL CONTRACTOR TO COME IN AND ADDRESS THE ABOVE. | | | | | | | | | ** AS STATED ABOVE. PLEASE CALL TO GO OVER ANY | | | COMMENTS. | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2009-08-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-08-20 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-08-20 |
Time |
16:55 |
Sent To |
|
|
| Notes |
| 2009-08-20 16:55:48 | *** REDLINED | | | | | | | | | 1) NOTE: RISER NOW REVISED TO REMOVE MAIN. EQUIPMENT | | | GROUNDING CONDUCTOR STILL SHOWN BEFORE FIRST MEANS OF | | | DISCONNECT. THIS IS NOT PERMITTED. 250.6, 250.24 | | | | | | 2) NOTE: VIF RECESSED LIGHTING MEETING FBC | | | 13-606.AB.1.2.4 | | | | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2009-08-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-08-03 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-08-03 |
Time |
11:17 |
Sent To |
|
|
| Notes |
| 2009-08-03 11:17:27 | ** DENIED 2ND REVIEW ** | | | | | | *** THERE ARE SEVERAL ITEMS ON PLANS NOW SHOWN WHICH | | | WERE NOT ON PREVIOUS SUBMITTED PLANS. SOME OF THESE | | | HAVE CREATED NEW COMMENTS WHICH COULD NOT HAVE BEEN | | | PREVIOUSLY MADE. | | | PANEL SCHEDULE AND EQUIPMENT ON PANEL HAS BEEN | | | COMPLETELY REVISED. | | | | | | 1) NOTE: ELECTRICAL RISER INDICATES A MAIN DISCONNECT | | | AFTER METER, YET THIS IS NOT SHOWN ON THE PLANS. THE | | | PLANS ONLY INDICATE THE PANEL AND THE METER. | | | PANEL SCHEDULE INDICATES PANEL AS MLO. A MAIN WOULD BE | | | REQUIRED EITHER AHEAD OF PANEL OR IN PANEL IF LOCATED | | | PER 230.70,230.71, | | | 240.24,110.26 ETC | | | | | | 2) NOTE: PREVIOUS PANEL SCHEDULE INDICATED A STORAGE | | | TYPE WATER HEATER AND THE REVIEW COMMENT WAS TO SHOW | | | LOAD AT 125%. THE PLANS ALSO INDICATED A INSTA-HOT. | | | HOWEVER THE NEW PLANS ONLY INDICATES ONE *INSTA-HOT* | | | LOCATED UNDER THE COUNTER IN THE BATHROOM AND PER THE | | | PANEL SCHEDULE THIS IS NOW A GAS APPLIANCE. | | | PLEASE SEE PLUMBING REVIEW COMMENTS FOR LOCATION. | | | PLEASE ALSO EXPLAIN WHERE THE REMAINDER OF THE HOT | | | WATER IS BEING FED FROM. IS THERE GOING TO BE ANOTHER | | | GAS OR ELECTRIC WATER HEATING SOURCE? | | | THERE ARE UNANSWERED QUESTIONS ON THIS AT THIS TIME. | | | SEE 422.13, 220.87 ETC | | | | | | 3) NOTE: PLEASE PREVIOUS PLANS WHICH PANEL SCHEDULE | | | INDICATED A 101KW AHU WITH 2-60 ON #6AWG WHICH WAS OK. | | | HOWEVER THE PANEL SCHEDULE NOW INDICATES THIS SAME AHU | | | INDICATES AN EVEN HIGHER LOAD AT 12KW. THE OVER CURRENT | | | PROTECTION IS LESS AND SMALLER BRANCH CIRCUIT | | | CONDUCTORS ARE ALSO SHOWN. THESE DO NOT MEET 424.3B FOR | | | MINIMUM OCP AND 310.16, 240.4 FOR BRANCH CIRCUIT | | | CONDUCTORS. | | | PLEASE SEE NEW AHU #2 AND #3 WHICH BOTH SHOW 40AMP OCP | | | FOR TWO DIFFERENT HEAT LOADS. THIS DOES NOT SEEM | | | POSSIBLE. | | | MECHANICAL PLANS DO NOT GIVE ANY INFORMATION. | | | | | | 4) NOTE: SAME AS PREVIOUS REVIEW: PLEASE IDENTIFY THE | | | LIGHTING CONTROL SWITCHES WITH THE RESPECTIVE 3-WAY OR | | | 4-WAY DESIGNATION. THERE ARE MORE THAN ONE LOCATION | | | STILL SHOWN. 210.70 | | | | | | 5) NOTE: PLEASE SEE 210.52 FOR RECEPTACLES SPACING | | | ALONG AREAS IN WHICH THERE IS MORE THAN 2FT OF | | | INDIVIDUAL WALL SPACE. ( BEDRM #3 FOR EXAMPLE) | | | | | | 6) NOTE: PLEASE SEE FBC 13-606.AB1.2.4 AS ALL RECESSED | | | TYPE LIGHT FIXTURES SHALL MEET SECTION GIVEN. PLEASE BE | | | SURE TO UPDATE TYPE OF FIXTURES ON PLANS. | | | | | | 7) NOTE: PLEASE SHOW LOCATION FOR THE NEW 30AMP | | | RECEPTACLE FOR MICROWAVE. | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2009-06-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-06-18 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-06-18 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2009-06-18 15:57:37 | | | | ** DENIED PLANS * | | | | | | 1) NOTE: PLEASE SEE FS 481.229, 471.003 AND 489 FOR | | | REQUIRED DESIGN PROFESSIONAL. NO DESIGN PROFESSIONAL | | | SHOWN. PLANS MUST BE DONE BY ONE OF THE SECTIONS GIVEN. | | | | | | 2) NOTE: PLEASE CLARIFY SHEETS SUBMITTED. NOTE THE FACT | | | THAT THE ELECTRICAL SHEET 5.1 CLEARLY STATES *SHEET 8 | | | OF 7* HOW IS THIS POSSIBLE? PLEASE COORDINATE ALL PLANS | | | AND DOCUMENTS. | | | | | | 3) NOTE: PLEASE PROVIDE LAYOUT OF EXISTING DWELLING | | | SHOWING NEW OR EXISTING SMOKE ALARMS MEETING CURRENT | | | NFPA-72. PLEASE KNOW THAT PER FS 553.885 IF THE HOUSE | | | HAS AN ATTACHED GARAGE OR GAS APPLIANCES ONE CARBON | | | MONOXIDE DETECTOR IS REQUIRED. A SMOKE ALARM DEVICE CAN | | | BE A COMBINATION DEVICE WITH THE CARBON MONOXIDE | | | DETECTORS. | | | IF EXISTING DOES NOT MEET CURRENT NFPA-72, THEN ALL | | | MUST BE BROUGHT UP TO CODE. PLEASE KEEP IN MIND THE ARC | | | FAULT PROTECTION PER 210.12 OF THE 2005 NEC. | | | 11.8.3, 11.5.1.1, FBC R313.1 | | | SMOKE ALARM TOO CLOSE TO BATHROOM DOOR 11.8.3 | | | | | | 4) NOTE: PLEASE SEE 422.13 AS THE WATER HEATER LOAD | | | SHALL BE FIGURED AT 125% AS A CONTINUOUS LOAD. ( SEE | | | NEC HANDBOOK). | | | | | | 5) NOTE: PLEASE COORDINATE THE PLANS WITH THE | | | ELECTRICAL RISER AS SHOWN. PLANS ONLY INDICATE A METER | | | LOCATED OUTSIDE WHEREAS THE RISER CLEARLY SHOWS A MAIN | | | TO BE INSTALLED. | | | RISER IS CONFUSING AS THE RISER INDICATES A NEW MAIN TO | | | BE INSTALLED YET THE RISER IS ALSO NOTED AT *EXISTING*. | | | WHICH IS IT? | | | 110.26, 240.24, 230.70/71 | | | FBC 106.1.1 FOR CLARITY AND COORDINATION OF PLANS. | | | | | | 6) NOTE: PLANS INDICATE THERE IS GOING TO BE A NEW | | | INSTA-HOT HOWEVER THE PANEL SCHEDULE/LOAD CALCULATIONS | | | AND PLUMBING PLANS DO NOT INDICATE ANY OF THIS? | | | 408.4,240.4,310.16,220 ETC | | | | | | 7) NOTE: PLEASE IDENTIFY THE LIGHTING CONTROL SWITCHES | | | WITH THE RESPECTIVE 3-WAY OR 4-WAY DESIGNATION. | | | PLEASE ALSO SEE DOOR AREA OFF DINING ROOM WHICH THERE | | | IS NO LIGHT ILLUMINATING THE EGRESS AREA. THERE ARE | | | SEVERAL WAYS OF DOING THIS. PLEASE SHOW ONE *MINIMUM | | | CODE REQUIRED* METHOD. | | | 210.70 | | | | | | 8) NOTE: PLEASE SEE 210.52 FOR RECEPTACLES SPACING | | | ALONG AREAS IN WHICH THERE IS MORE THAN 2FT OF | | | INDIVIDUAL WALL SPACE. ( BEDRM #3 FOR EXAMPLE) | | | | | | 9) NOTE: PLEASE SEE FBC 13-606.AB1.2.4 AS ALL RECESSED | | | TYPE LIGHT FIXTURES SHALL MEET SECTION GIVEN. PLEASE BE | | | SURE TO UPDATE TYPE OF FIXTURES ON PLANS. | | | | | | 10) NOTE: PLEASE SEE 210.52B1, 210.11C1 AND 220.53 AS | | | ONE OR MORE OF THE SMALL APPLIANCE CIRCUITS SHALL BE | | | FIGURED AT 1500VA FOR EACH. PLANS SHOW THE TWO MINIMUM | | | KITCHEN SMALL APPLIANCES HOWEVER THE 1500VA IS FOR EACH | | | INCLUDING AND ABOVE THE TWO. FOR EXAMPLE: DINING ROOM, | | | AND AREAS OF THE LIKE. | | | | | | | | | ** IMPORTANT ** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2009-09-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-09-08 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2009-09-08 |
Time |
14:28 |
Sent To |
|
|
| Notes |
| 2009-09-08 14:28:59 | INCOMING TO R-11 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2009-08-12 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-08-12 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-08-12 |
Time |
09:08 |
Sent To |
|
|
| Notes |
| 2009-08-12 09:10:16 | TO R11 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2009-07-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-07-17 |
Time |
12:17 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-07-17 |
Time |
12:16 |
Sent To |
|
|
| Notes |
| 2009-07-17 12:20:41 | SENT TO R-25. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2009-06-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
shill |
Date |
2009-06-02 |
Time |
10:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2009-09-21 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-09-21 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-09-21 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2009-09-21 10:39:48 | REVISED AD.1 DELTA 3 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2009-08-24 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-08-24 |
Time |
12:06 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-08-24 |
Time |
10:48 |
Sent To |
|
|
| Notes |
| 2009-08-24 12:08:17 | **PROVISO** | | | 1. PROVIDE COMBUSTION OR MAKEUP AIR FOR NEW GAS DRYER | | | PER FBC-R G2407.1 OR FBC-R G2439.4 | | | | | | 2. PROVIDE BALANCED RETURN IN MASTER SUITE PER FBC-R | | | M1602.4 | | | | | | 3. PROVIDE NEW ENERGY CODE COMPLIANCE FORM PER BUILDING | | | PLAN REVIEW COMMENTS. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2009-07-28 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-07-28 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-07-28 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2009-07-28 11:37:22 | REVIEW #: 2ND | | | ACTION: DENIED | | | | | | FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | 1. NOT ADDRESSED: PLANS SHOW THE GARAGE BEING CONVERTED | | | TO A BEDROOM. ANY EXPANSION OF THE CONDITIONED SPACE IS | | | DEFINED AS AN ADDITION PER FBC-R SECTION N1100.7.3. | | | ADDITIONS TO EXISTING RESIDENTIAL BUILDINGS SHALL BE | | | CONSIDERED NEW BUILDING CONSTRUCTION AND SHALL COMPLY | | | WITH THE REQUIREMENTS OF EITHER METHOD A OR B AS | | | APPLICABLE PER FBC-R SECTION N1100.0.3. ADDITIONS THAT | | | ARE UNABLE TO COMPLY WITH CODE REQUIREMENTS FOR THE | | | ADDITION ALONE MAY COMPLY WITH THE CODE BY BRINGING THE | | | ENTIRE BUILDING INTO COMPLIANCE WITH SECTION | | | N1100.A.5.2. | | | | | | 2. PARTIALLY ADDRESSED: NO MECHANICAL INFORMATION IS | | | PROVIDED ON PLANS. PLEASE SHOW HOW EXISTING A/C SYSTEM | | | IS TO BE MODIFIED OR WHAT NEW SYSTEM IS BEING INSTALLED | | | FOR THE NEWLY CONDITIONED SPACE. AT A MINIMUM, | | | COMPLIANCE WITH FBC-R303.8 MUST BE SHOWN ON PLANS. | | | PROVIDE COOLING LOAD CALCULATIONS ATTACHED TO ENERGY | | | CALCULATIONS SHOWING EXISTING EQUIPMENT CAPABLE OF | | | ADDITIONAL COOLING LOADS. | | | | | | 3. PARTIALLY ADDRESSED: LOCATION OF BATH EXHAUST | | | TERMINATION STILL NOT SHOWN ON PLANS. | | | | | | 4. NEW PLANS NOW SHOW NEW GAS APPLIANCES BEING | | | INSTALLED. THE FOLLOWING SHALL BE ADDRESSED: | | | A. GAS DRYER: PROVIDE COMBUSTION AIR IN ACCORDANCE WITH | | | FBC-R SECTION G2407.1 OR MAKEUP AIR IN ACCORDANCE WITH | | | FBC-R SECTION G2439.4. | | | B. PAGE 5.1 SHOWS ONE CARBON MONOXIDE DETECTOR LOCATED | | | IN THE SITTING AREA. CARBON MONOXIDE ALARMS SHALL BE | | | LOACTED WITHIN 10 FEET OF SLEEPING ROOMS IN ACCORDANCE | | | WITH FBC-R313.4. | | | | | | 5. PAGE AD.1 SHOWS A DETAIL FOR ROOF MOUNTED DUCT. THE | | | PROPOSED DETAIL IS NOT CLEAR. IS THE DUCT SHOWN ON | | | PLANS TO BE RUN ON THE ROOF? IF SO, WHY IS THE DUCT | | | SHOWN ON THE PLANS ROUND WHILE THE SUPPORT DETAIL IS | | | FOR RECTANGULAR DUCT? HOW CAN THERE BE EXISTING | | | SLEEPERS ON A SECTION OF THE BUILDING WHICH WAS | | | PREVIOUSLY UNCONDITIONED? PLEASE CLARIFY AND SHOW | | | COMPLIANCE WITH THE WIND RESISTANCE REQUIREMENTS OF | | | FBC-R SECTION M1307.3. | | | | | | 6. RETURN TRANSFER DUCTS ARE NOT SIZED TO MEET THE | | | EXCEPTIONS UNDER FBC-R SECTION M1602.4. DESIGN RETURNS | | | TO MEET THESE EXCEPTIONS OR A FIELD TEST WILL BE | | | REQUIRED AT FINAL INSPECTION TO VERIFY MAXIMUM PRESSURE | | | DIFFERENTIAL IN ACCORDANCE WITH THIS SECTION. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2009-06-19 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-06-19 |
Time |
11:03 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-06-19 |
Time |
10:18 |
Sent To |
|
|
| Notes |
| 2009-06-19 11:03:28 | REVIEW #: 1ST | | | ACTION: DENIED | | | | | | FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENTS | | | FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | 1. PLANS SHOW THE GARAGE BEING CONVERTED TO A BEDROOM. | | | ANY EXPANSION OF THE CONDITIONED SPACE IS DEFINED AS AN | | | ADDITION PER FBC-R SECTION N1100.7.3. ADDITIONS TO | | | EXISTING RESIDENTIAL BUILDINGS SHALL BE CONSIDERED NEW | | | BUILDING CONSTRUCTION AND SHALL COMPLY WITH THE | | | REQUIREMENTS OF EITHER METHOD A OR B AS APPLICABLE PER | | | FBC-R SECTION N1100.0.3. ADDITIONS THAT ARE UNABLE TO | | | COMPLY WITH CODE REQUIREMENTS FOR THE ADDITION ALONE | | | MAY COMPLY WITH THE CODE BY BRINGING THE ENTIRE | | | BUILDING INTO COMPLIANCE WITH SECTION N1100.A.5.2. | | | | | | 2. NO MECHANICAL INFORMATION IS PROVIDED ON PLANS. | | | PLEASE SHOW HOW EXISTING A/C SYSTEM IS TO BE MODIFIED | | | OR WHAT NEW SYSTEM IS BEING INSTALLED FOR THE NEWLY | | | CONDITIONED SPACE. AT A MINIMUM, COMPLIANCE WITH | | | FBC-R303.8 MUST BE SHOWN ON PLANS. | | | | | | 3. SHOW LOCATION OF DRYER AND BATH EXHAUST TERMINATIONS | | | IN ACCORDANCE WITH FBC-R303.4, FBC-R303.5 AND FBC-R | | | SECTION M1501.1. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2009-11-16 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-11-16 |
Time |
10:04 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-11-16 |
Time |
10:04 |
Sent To |
B |
|
| Notes |
| 2009-11-16 10:05:29 | REVISION OK -- SHT 4.2 -- SANT. RISER DIAGRAM. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2009-09-14 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-09-14 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-09-14 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2009-09-14 13:55:09 | REVISION OK -- SHT 4.2 -- SANT RISER DIAGRAM. -- NOTE | | | CONCERNING GAS PERMIT BY INSTALLATION CONTRACTOR. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2009-08-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-08-06 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-08-06 |
Time |
15:44 |
Sent To |
|
|
| Notes |
| 2009-08-06 15:47:40 | | | | | | | | | | | | | PASSED/PROVISO: | | | A REVISION IS REQUIRED FOR THE SANITARY ISOMETRIC RISER | | | DIAGRAM SHOWING THE CONNECTION OF THE BUILDING DRAIN TO | | | THE BUILDING SEWER. | | | | | | SHT 5.1 PANEL BOARD SCHEDULE INDICATES A GAS RANGE & | | | GAS INSTA-HOT WATER HEATER. A SEPARATE GAS PERMIT IS | | | REQUIRED WITH GAS PLANS. | | | | | | | | | | | | | | | . |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2009-06-15 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-06-15 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-06-15 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2009-06-15 15:53:28 | PASSED/PROVISO: | | | | | | REVISION REQUIRED SHOWING THE CONNECTION TO THE | | | BUILDING DRAIN/BUILDING SEWER AND SHOW THE TRAP TO THE | | | SHOWER. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2009-06-22 |
|
|
Cont ID |
|
| Sent By |
mcruz |
Date |
2009-06-22 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
mcruz |
Date |
2009-06-22 |
Time |
11:48 |
Sent To |
|
|
| Notes |
| 2009-06-22 11:50:01 | *ZONING REVIEW NOT REQUIRED: INTERIOR WORK ONLY AND THE | | | VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE | | | IMPROVEMENT VALUE. | | | | | | MAGGIE CRUZ, ASSOCIATE PLANNER | | | PLANNING AND ZONING DEPARTMENT | | | TEL: (561) 822-1444 OR (561) 805-6720 | | | E-MAIL: [email protected] | | | |
|
|