Plan Review Details - Permit 09050571
Plan Review Stops For Permit 09050571
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2009-11-03 Cont ID  
Sent By jgomez Date 2009-11-03 Time 16:56 Rev Time 0.00
Received By jgomez Date 2009-11-03 Time 16:55 Sent To  
Notes
2009-11-03 16:56:17REVISION.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-07-23 Cont ID  
Sent By jgomez Date 2009-07-23 Time 16:20 Rev Time 0.00
Received By jgomez Date 2009-07-23 Time 16:03 Sent To PC
Notes
2009-07-23 16:28:09BUILDING REVIEW APPROVED WITH PROVISO:
  
 1- PROVIDE COMPLETE SHUTTERS INSTALLATION SCHEDULE (SEE
 ATTACHED SAMPLE) AND CLEARLY MARK ON SHUTTERS DRAWINGS
 SPECIFIC ANCHOR TYPE AND SPACING TO BE USED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-06-09 Cont ID  
Sent By jgomez Date 2009-06-09 Time 16:48 Rev Time 0.00
Received By jgomez Date 2009-06-09 Time 16:48 Sent To  
Notes
2009-06-09 17:05:57RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW CHECKLIST.
 REVIEW UNDER 2007 FLORIDA RESIDENTIAL CODE.
  
 1- NEED RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13
 FLORIDA STATUTE.
 NOTE: THIS MAY BE RECORDED AT TIME OF PERMIT PICK UP.
  
 2- CLARIFY HOW PROVIDING CROSS VENTILATION ON FLAT ROOF
 AS REQUIRED BY SEC. R806.1 OF 2007 FLORIDA RESIDENTIAL
 CODE. REVISE GENERAL NEW CONSTRUCTION NOTES #10 ON
 SHEET A-2. VENTS SPACED AT 8'-0" DON'T PROVIDE
 VENTILATION TO ALL ROOF RAFTERS.
  
 3- PROVIDE PRODUCT APPROVALS AS REQUIRED BY DCA RULE
 9B-72 FOR:
 A) GLASS BLOCK SHOWN ON MASTER BATHROOM AREA.
  
 B) WINDOW MULLIONS. AND, MARK ON DRAWINGS SPECIFIC
 MULLION SIZE AND ANCHORS TO VERIFY COMPLIANCE WITH THE
 CALCULATED DESIGN PRESSURES OF SEC. R301 OF 2007
 FLORIDA RESIDENTIAL CODE. COORDINATE DESIGN PRESSURES
 WITH ITEM #6 BELOW.
  
 C) DOUBLE DOORS AT NEW LAUNDRY AREA.
  
 D) ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON
 DETAILS. PROVIDE ONLY THE FLORIDA PRODUCT APPROVAL
 COVER PAGE AND PAGE SHOWING THE CONNECTOR.
  
 E) FIXED WINDOWS.
  
 4- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 ALL PRODUCT APPROVALS AS REQUIRED BY SEC. 106.3.3 CITY
 AMENDMENTS TO FBC.
  
 5- STORM SHUTTERS: PROVIDE COMPLETE INSTALLATION
 SCHEDULE. SEE ATTACHED SAMPLE. AND, MARK ON SHUTTERS
 DRAWINGS SPECIFIC MOUNTING CONDITIONS (EG: WALL
 MOUNTED, BUILD OUT, ETC) . ALSO, MARK ON DRAWINGS
 SPECIFIC ANCHOR TYPE AND SPACING TO BE USED ACCORDING
 TO THE DESIGN PRESSURES, EDGE DISTANCE, SHUTTERS SPAN
 AND STRUCTURE TO BE ATTACHED TO.
  
 6- REVISE DESIGN PRESSURES SHOWN ON SHEET A-2 FOR DOORS
 AND WINDOWS. ACCORDING TO 2009 REVISIONS TO SEC. R301
 TO THE 2007 FLORIDA RESIDENTIAL CODE THIS BUILDING IS
 LOCATED ON EXPOSURE "C", NOT "B". REVISE AS REQUIRED.
  
 7- SPECIFY SAFETY GLASS FOR BATHROOM WINDOW AS REQUIRED
 BY SEC. R308.4 OF 2007 FLORIDA RESIDENTIAL CODE.
  
 8- SPECIFY TYPE AND SIZE OF EXISTING BEDROOM WINDOWS TO
 BE REPLACED AND OPENINGS TO BE CLOSED TO VERIFY
 COMPLIANCE WITH THE EGRESS REQUIREMENTS OF SEC. 601.2
 OF 2007 FLORIDA EXISTING BUILDING CODE.
  
 9- SPECIFY MIN. STUCCO THICKNESS (7/8") AS REQUIRED BY
 TABLE R702.1(1) OF 2007 FLORIDA RESIDENTIAL CODE.
  
 10- UPDATE PERMIT VALUATION TO INCLDUE ALL WORK SHOWN
 ON PLANS SUBMITTED. VALUATION TO INCLUDE ALL
 PROFESSIONAL DESIGN FEES, LABOR, MATERIALS AND
 CONTRACTOR'S OVERHEAD AND PROFIT AS REQUIRED BY SEC.
 108.3 CITY AMENDMENTS TO FBC. ALSO, CLARIFY IF PAVERS
 AND SIDEWALKS AS SHOWN ON SITE PLAN ARE PART OF THIS
 PERMIT. COORDINATE WITH ZONING. CALL 805-6720
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CALL
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2009-11-18 Cont ID  
Sent By btrobaug Date 2009-11-18 Time 15:17 Rev Time 0.00
Received By btrobaug Date 2009-11-18 Time 14:36 Sent To  
Notes
2009-11-18 15:18:53SMALL HOLDING BIN UNDER "T"./WRT.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2009-07-17 Cont ID  
Sent By btrobaug Date 2009-07-17 Time 11:15 Rev Time 0.00
Received By btrobaug Date 2009-07-17 Time 11:13 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2009-06-02 Cont ID  
Sent By btrobaug Date 2009-06-02 Time 14:25 Rev Time 0.00
Received By btrobaug Date 2009-06-02 Time 14:24 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2009-10-28 Cont ID  
Sent By rmcdouga Date 2009-10-27 Time 10:33 Rev Time 0.00
Received By rmcdouga Date   Time   Sent To  
Notes
2009-10-28 10:34:03TO R-22

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-07-17 Cont ID  
Sent By btrobaug Date 2009-07-06 Time 11:13 Rev Time 0.00
Received By btrobaug Date 2009-07-06 Time 09:44 Sent To  
Notes
2009-07-17 11:18:08 
 R 23

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2009-06-16 Time   Rev Time 0.00
Received By btrobaug Date 2009-06-02 Time 14:24 Sent To  
Notes
2009-06-02 14:24:50R-6

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2009-11-05 Cont ID  
Sent By jgomez Date 2009-11-05 Time 14:11 Rev Time 0.00
Received By jgomez Date 2009-11-05 Time 14:11 Sent To  
Notes
2009-11-05 14:12:07REVISION.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2009-06-16 Cont ID  
Sent By rregueir Date 2009-06-16 Time 09:04 Rev Time 0.00
Received By rregueir Date 2009-06-16 Time 08:56 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2009-11-02 Cont ID  
Sent By kstevens Date 2009-11-02 Time 13:56 Rev Time 0.00
Received By kstevens Date 2009-11-02 Time 13:56 Sent To  
Notes
2009-11-02 14:01:57DENIED
 REFERENCE:
 FBC-2007 RESIDENTIAL
  
 1. SHT A-2 SANITARY RISER DIAGRAM DOES NOT MEET CODE
 REQUIREMENTS. 3" BRANCH LINE & STACK ARE REQUIRED PER
 SECTION P2718.1. (THIS WILL REFLECT THE INSTALLATION).
 THE WASH MACHINE SHALL NOT DRAIN THROUGH THE HORIZONTAL
 WET VENT OF THE BATHROOM FIXTURES, BUT SHALL DISCHARGE
 DOWNSTREAM OF THE FIXTURES. SECTION P3108.1.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status N Date 2009-07-13 Cont ID  
Sent By kstevens Date 2009-07-13 Time 08:12 Rev Time 0.00
Received By kstevens Date 2009-07-10 Time 16:58 Sent To  
Notes
2009-07-13 08:13:11PLANS PREVIOUSLY APPROVED

Review Stop P PLUMBING
Rev No 1 Status P Date 2009-06-15 Cont ID  
Sent By kstevens Date 2009-06-15 Time 14:47 Rev Time 0.00
Received By kstevens Date 2009-06-15 Time 14:47 Sent To  
Notes
2009-06-15 14:49:09PASSED/PROVISO:
  
 MINIMUM 3" REQUIRED TO THE WASH MACHINE.

Review Stop Z ZONING
Rev No 2 Status P Date 2009-07-22 Cont ID  
Sent By mcruz Date 2009-07-13 Time 15:54 Rev Time 0.00
Received By mcruz Date 2009-07-13 Time 12:51 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status N Date 2009-06-09 Cont ID  
Sent By mcruz Date 2009-06-09 Time 15:53 Rev Time 0.00
Received By mcruz Date 2009-06-09 Time 15:53 Sent To  
Notes
***NONE***