Plan Review Details - Permit 09050486
Plan Review Stops For Permit 09050486
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2009-07-22 Cont ID  
Sent By jgomez Date 2009-07-22 Time 16:58 Rev Time 0.00
Received By jgomez Date 2009-07-22 Time 16:58 Sent To  
Notes
2009-07-22 17:14:59BUILDING REVIEW APPROVED WITH PROVISO.
  
 1- REVISE SUBMITTED ENERGY CALCULATIONS:
 A) R-19 CEILING INSULATION CAN'T BE ACHIEVED ON ON 2X6
 ROOF RAFTERS. NEED SPACE FOR VENTILATION. SEE SEC.
 N1104.AB.1.
 B) BUILDING ADDITION CAN'T TAKE THE WHOLE HOUSE FAN
 CREDIT. SEE SEC. N1107.A.6. IT DOESN'T MEET THE
 CRITERIA IN SECTION B4.1.4 OF APPENDIX G-B.
  
 2- REVISE RAS 117 CALCULATIONS. DESIGN PRESSURES DON'T
 CORRESPOND TO EXPOSURE "C".

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2009-06-08 Cont ID  
Sent By jgomez Date 2009-06-08 Time 15:46 Rev Time 0.00
Received By jgomez Date 2009-06-08 Time 15:46 Sent To  
Notes
2009-06-08 16:15:20RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW CHECKLIST.
 REVIEW UNDER 2007 FBC WITH 2009 REVISIONS.
  
 1- PROVIDE RECORDED NOTICE OF COMMENCEMENT. SEC. 713.13
 FLORIDA STATUTE. NOTE: THIS MAY BE RECORDED AT TIME OF
 PERMIT PICK UP.
  
 2- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO
 LOW. REVISE VALUATION TO INCLUDE ALL MATERIALS, LABOR
 AND ALL PROFESSIONAL FEES AS REQUIRED BY SEC. 108.3
 CITY AMENDMENTS TO FBC.
  
 3- PROVIDE ENERGY CALCULATIONS AS REQUIRED BY SEC.
 N1100.0.3 OF 2007 FLORIDA RESIDENTIAL CODE.
  
 4- TAKE PLANS TO PALM BEACH COUNTY (2300 N. JOG RD) TO
 VERIFY IF IMPACT FEES ARE DUE. BRING BACK STAMPED PLANS
 AND COPY OF PAID RECEIPT IF FEES ARE DUE.
  
 5- SHEET 1.0 NEEDS TO BE SIGNED AND SEALED BY THE
 ENGINEER AS REQUIRED BY SEC. 471 FLORIDA STATUTE.
  
 6- SHEET 2.0:
 A) UPDATE GENERAL DEMOLITION NOTE #1. REFER TO 2009
 REVISIONS, NOT 2007.
  
 B) SPECIFY SIZE AND TYPE OF EXISTING BEDROOM WINDOWS
 THAT ARE GOING TO BE REMOVED. AND SIZE AND TYPE OF
 BEDROOM WINDOWS TO REMAIN TO VERIFY COMPLIANCE WITH THE
 EGRESS REQUIREMENTS OF SEC. 601.2 OF 2007 FLORIDA
 EXISTING BUILDING CODE.
  
 7- SHEET 3.0: REVISE THICKNESS OF STUCCO SHOWN ON WALL
 LEGEND. NEED 7/8" STUCCO THICKNESS AS REQUIRED BY TABLE
 R702.1(1) OF 2007 FLORIDA RESIDENTIAL CODE.
  
 8- SHEET 3.1:
 A) REVISE STUCCO THICKNESS ON DETAILS LEGEND #5.
 REQUIRES 7/8" STUCCO, NOT 3/4". TABLE R702.1(1).
  
 B) CLARIFY WHY THE WINDOW/DOOR SCHEDULE CALLS FOR MAX.
 AND MIN. WIND PRESSURES INSTEAD OF POSITIVE AND
 NEGATIVE PRESSURES.
  
 9- SHEET 6.2: SPECIFY HOW LONG ARE THE 1/2" ANCHOR
 BOLTS SPECIFIED ON DETAILS 1 AND 2 TO HOLD THE 2X6
 BOTTOM PLATE. SEC. 106.1.2 CITY AMENDMENTS TO FBC.
  
 10- PROVIDE ENGINEERING ANALYSIS SHOWING WHY THE 2X6
 WOOD LEDGER THAT IS RECEIVING ENTIRE ROOF IS ONLY
 ATTACHED TO THE WALL SHEATHING AND NOT TO THE STUDS.
 SEC. 106.1.2 CITY AMENDMENTS TO FBC TO VERIFY
 COMPLIANCE WITH THE CALCULATED DESIGN PRESSURES.
  
 11- SHEET 7.1:
 A) DETAIL 1: REVISE STUCCO THICKNESS TO COMPLY WITH
 TABLE R702.1(1). ALSO, COORDINATE LEDGER ATTACHMENT
 WITH ITEM #10 ABOVE.
  
 B) DETAIL 2: COORDINATE LEDGER ATTACHMENT WITH ITEM #10
  
 12- SHEET 7.2: REVISE NOTE BELOW WIND LOAD SCHEDULE.
 REFER TO 2007 FBC WITH 2009 REVISIONS, NOT 2004.
  
 13- SHEET 8:
 A) NEED TO PROVIDE CONTINUOUS VENTILATION AS REQUIRED
 BY SEC. R806 OF 2007 FLORIDA RESIDENTIAL CODE.
  
 B) REVISE STUCCO THICKNESS. SEE ITEM #8 ABOVE.
  
 C) LEDGER ATTACHMENT TO EXISTING WALL. COORDINATE WITH
 ITEM #10 ABOVE.
  
 D) CLARIFY SIZE OF ANCHOR HOLDING THE BOTTOM PLATE.
 1/2" OR 5/8". COORDINATE WITH DETAILS ON SHEET 6.2.
 ALSO, SPECIFY HOW LONG ARE THEY REQUIRED TO BE. SEC.
 106.1.2 CITY AMENDMENTS TO FBC.
  
 14- PROVIDE PRODUCT APPROVAL FOR ALL SIMPSON STRUCTURAL
 CONNECTORS SPECIFIED ON PLANS AND DETAILS AS REQUIRED
 BY DCA RULE 9B-72. PROVIDE ONLY THE FLORIDA PRODUCT
 APPROVAL COVER PAGE AND PAGE SHOWING THE CONNECTOR.
  
 15- ENGINEER OF RECORD TO REVIEW AND APPROVE (NOT
 SIGNING AND SEALING) ALL PRODUCT APPROVALS. RUBBER
 STAMP SAYING THAT THIS PRODUCT APPROVAL HAS BEEN
 REVIEWED DOESN'T IDENTIFY THE ENGINEER WHO REVIEWED. IN
 ADDITION ALL FLORIDA PRODUCT APPROVAL SUBMITTED WERE
 REMOVED FROM THE SUBMITTED PACKAGE BECAUSE THEY
 CORRESPOND TO 2004 CODE AND CODE IN EFFECT IS 2007. YOU
 MAY USE NOA ALONE.
  
 16- FLAT ROOF PRODUCT APPROVAL NOA 07-1219.09 SUBMITTED
 REQUIRES RAS 117 CALCULATIONS FOR NAIL ENHANCING AT
 PERIMETER AND CORNER AREAS. SUCH CALCULATIONS NEED TO
 BE SIGNED AND SEALED AS REQUIRED BY GENERAL LIMITATION
 #7 ON SHEET 19 OF NOA SUBMITTED. PROVIDE SIGNED AND
 SEALED CALCULATIONS.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2009-07-17 Cont ID  
Sent By btrobaug Date 2009-07-17 Time 11:33 Rev Time 0.00
Received By btrobaug Date 2009-07-17 Time 11:28 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2009-06-04 Cont ID  
Sent By btrobaug Date 2009-06-04 Time 10:27 Rev Time 0.00
Received By btrobaug Date 2009-06-04 Time 10:26 Sent To  
Notes
2009-06-04 10:27:12 
  
  
 THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES:
  
 THE 2007 FLORIDA RESIDENTIAL BUILDING CODE, 2009
 REVISIONS, 2005 NEC, 2004 FBC AS AMENDED, CHAPTER 1.AND
 FOUND NONCOMPLIANT WITH THE FOLLOWING
  
 1} THE ENGINEER WHOSE NAME APPEARS ON THE TITLE BLOCK
 MUST SIGN, DATE AND SEAL THE DOCUMENT. 61G15-23.002
 FAC.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2010-04-05 Cont ID  
Sent By astelly Date 2010-04-08 Time 16:02 Rev Time 0.00
Received By lmartine Date 2010-04-01 Time 09:24 Sent To  
Notes
2010-04-05 09:25:202 COPIES OF SURVEY, FOR AMY, PUT IN ZONING BOX

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2010-02-03 Cont ID  
Sent By rmcdouga Date 2010-02-02 Time 09:50 Rev Time 0.00
Received By rmcdouga Date 2010-02-02 Time 09:50 Sent To  
Notes
2010-02-03 09:50:55TO ZONING BOX

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2009-08-19 Cont ID  
Sent By lmartine Date 2009-08-19 Time 13:58 Rev Time 0.00
Received By lmartine Date 2009-08-19 Time 13:58 Sent To  
Notes
2009-08-19 13:58:52R-5

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2009-07-23 Cont ID  
Sent By btrobaug Date 2009-07-06 Time 11:26 Rev Time 0.00
Received By jgomez Date 2009-07-06 Time 09:40 Sent To  
Notes
2009-07-06 09:44:02R-27

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2009-06-08 Cont ID  
Sent By jgomez Date 2009-06-08 Time 16:53 Rev Time 0.00
Received By jgomez Date 2009-05-26 Time 10:40 Sent To  
Notes
2009-06-02 11:35:14TO R-16
2009-05-26 10:41:36TO ZONING IN BOX./WRT

Review Stop L LANDSCAPING
Rev No 2 Status N Date 2010-08-30 Cont ID  
Sent By rkussner Date 2010-08-30 Time 18:18 Rev Time 0.00
Received By rkussner Date 2010-08-30 Time 18:18 Sent To  
Notes
2010-08-30 18:20:04***LANDSCAPE NOT REQUIRED FOR THIS PERMIT***
  
 PLEASE REFER TO PERMIT #10070231 FOR THE LANDSCAPE
 PLAN.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.

Review Stop L LANDSCAPING
Rev No 1 Status F Date 2010-04-08 Cont ID  
Sent By rkussner Date 2010-04-08 Time 15:35 Rev Time 0.00
Received By rkussner Date 2010-04-08 Time 15:35 Sent To  
Notes
2010-04-08 15:54:46***LANDSCAPE REVIEW FAILED***
  
 PLEASE RESPOND TO REVIEW COMMENTS IN WRITTEN FORMAT.
  
 1. A SEPARATE LANDSCAPE PERMIT IS REQUIRED. PLEASE
 SUBMIT AN APPLICATION AND (2) COPIES OF A LANDCAPE
 PLAN. THE PLAN SHALL INCLUDE A COST ESTIMATE THAT
 INCLUDES THE TOTAL COST OF ALL LANDSCAPE MATERIALS AND
 LABOR, BROKEN DOWN INTO UNIT COST.
  
 2. PLEASE PROVIDE THE TABULATION NECESSARY FOR THE
 EVALUATION OF COMPLIANCE WITH ARTICLE XIV OF THE ZONING
 AND LAND DEVELOPMENT REGULATIONS, INCLUDING THE
 XERISCAPE DESIGN OPTIONS.
  
 3. PURSUANT TO SECTION 94-448 (D) (2), THE LANDSCAPE
 PLAN SHALL INCLUDE ALL OF THE ITEMS ENUMERATED IN THIS
 SECTION.
  
 4. PURSUANT TO SECTION 94-442 (D), PRIVATE LAND AND
 PUBLIC RIGHTS-OF-WAY BETWEEN STREET OR SIDEWALK
 SURFACES AND REQUIRED BUFFER STRIPS AND LANDSCAPED OPEN
 SPACE AREAS SHALL BE PLANTED WITH GRASS. GRASS AREAS
 SHALL BE SODDED. PLEASE SOD THE AREAS THAT ARE
 CURRENTLY SHOWN AS MULCH.
  
 5. ALL UTILITIES (OVERHEAD AND UNDERGROUND), EASEMENTS,
 OVERHANGING TREE CANOPIES AND ANYTHING ELSE THAT MAY
 IMPACT THE PROPOSED LANDSCAPING SHALL BE SHOWN ON THE
 LANDSCAPE PLAN.
  
 6. ALL PROPOSED PLANT MATERIAL SHALL BE IDENTIFIED BY
 NAME, QUANTITY, SIZE AND SPACING.
  
 7. ADDITIONAL COMMENTS WILL BE FORTHCOMING ONCE A MORE
 COMPLETE PLAN HAS BEEN SUBMITTED.
  
 8. PURSUANT TO SECTION 94-445 (4) (G) (3), AUTOMATIC
 IRRIGATION SYSTEMS SHALL BE USED FOR THE CULTIVATED
 LANDSCAPE AREAS FOR ALL PROPERTIES AND PROVIDE 120%
 COVEAGE. PLEASE APPLY FOR AN IRRIGATION PERMIT AND
 SUBMIT (2) COPIES OF AN IRRIGATION PLAN. THE SYTEMS
 SHALL BE EQUIPPED WITH A PRESSURE VACUUM BREAKER VALVE
 AND A RAIN SENSING DEVICE.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT ROBERT
 KUSSNER @ (561) 822-1462.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2009-08-27 Cont ID  
Sent By rregueir Date 2009-08-27 Time 19:10 Rev Time 0.00
Received By rregueir Date 2009-08-27 Time 19:10 Sent To Z
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2009-07-27 Cont ID  
Sent By rregueir Date 2009-07-27 Time 11:55 Rev Time 0.00
Received By rregueir Date 2009-07-27 Time 11:08 Sent To  
Notes
2009-07-27 11:55:42REVIEW #: 2ND
 ACTION: DENIED
  
 FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENTS
 FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH
  
 1. OK
  
 2. OK
  
 3. OK
  
 4. PLANS NOW CALL FOR 3" ROUND DRYER EXHAUST. IF THIS
 SIZE IS CORRECT, PLEASE SUBMIT MANUFACTURER'S
 INSTALLATION INSTRUCTIONS IN ACCORDANCE WITH FBC-R
 SECTION M1502.3. OTHERWISE, PLEASE SHOW THE STANDARD 4"
 ROUND SIZE.
  
 5. ENERGY CALCULATIONS HAVE BEEN SUBMITTED, HOWEVER
 THEY DO NOT ACCURATELY REFLECT THE HOME CONSTRUCTION.
 THIS PROJECT IS NOT ELIGIBLE FOR THE WHOLE HOUSE FAN
 CREDIT IN ACCORDANCE WITH FBC-R SECTION N1107.A.6.
 RESUBMIT ENERGY CALCULATIONS WITHOUT THE WHOLE HOUSE
 FAN CREDIT. ALSO, COOLING LOAD CALCULATIONS SHALL BE
 ATTACHED TO THE ENERGY CALCULATIONS IN ACCORDANCE WITH
 FBC-R SECTION N1107.AB.1.
  
 6. OK
  
 7. OK
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2009-06-04 Cont ID  
Sent By rregueir Date 2009-06-04 Time 14:37 Rev Time 0.00
Received By rregueir Date 2009-06-04 Time 13:44 Sent To  
Notes
2009-06-04 14:37:44REVIEW #: 1ST
 ACTION: DENIED
  
 FBC 2007 CODE FAMILY W/ 2009 SUPPLEMENTS
 FBC CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH
  
 1. UPDATE ALL CODE REFERENCES ON PLANS TO REFLECT THE
 CODE IN EFFECT AT TIME OF PERMIT APPLICATION. THE
 CURRENT CODE AS OF MARCH 1, 2009 IS THE 2007 FBC W/
 2009 SUPPLEMENT.
  
 2. A MECHANICAL PERMIT HAS BEEN APPLIED FOR BUT NO
 MECHANICAL PLANS WERE PROVIDED FOR THIS REVIEW. PROVIDE
 PLAN SHOWING IN DETAIL THE MECHANICAL SCOPE OF WORK IN
 ACCORDANCE WITH FBC-B 106.1.1.
  
 3. ELECTRICAL PLAN SHOWS NEW EXHAUST FAN IN BATHROOM.
 SHOW SIZE OF DUCT AND EXHAUST TERMINATION LOCATION IN
 ACCORDANCE WITH FBC-R SECTION M1501.1.
  
 4. SHOW MEANS AND LOCATION OF DRYER EXHAUST IN
 ACCORDANCE WITH FBC-R SECTION M1502.
  
 5. NO ENERGY CALCULATIONS WERE PROVIDED AS PART OF THIS
 REVIEW. ANY INCREASE IN THE CONDITIONED FLOOR AREA IS
 CONSIDERED AN ADDITION IN ACCORDANCE WITH FBC-R SECTION
 N1100.7. ADDITIONS SHALL BE TREATED AS NEW CONSTRUCTION
 AND SHALL DEMONSTRATE COMPLIANCE BY SUBMITTING FORM
 1100A-08 OR FORM 1100B-08 IN ACCORDANCE WITH FBC-R
 SECTION N1100.0.3. THIS BUILDING IS NOT EXEMPT FROM
 ENERGY EFFICIENCY REQUIREMENTS AS THE ELECTRICAL SYSTEM
 HAS BEEN DESIGNED TO ACCOMMODATE THE FUTURE
 INSTALLATION OF HEATING OR COOLING EQUIPMENT IN
 ACCORDANCE WITH FBC-R SECTION N1100.0.1.
  
 6. ACCORDING TO PAGE 2.0, TWO WINDOWS ON THE EXISTING
 HOUSE ARE BEING ELIMINATED. THIS CONSTITUTES A LEVEL 2
 ALTERATION (AS DECLARED ON PLANS). ALL RECONFIGURED
 SPACES INTENDED FOR OCCUPANCY IN ANY WORK AREA SHALL BE
 PROVIDED WITH NATURAL OR MECHANICAL VENTILATION OR
 EXHAUST IN ACCORDANCE WITH THE FLORIDA BUILDING CODE,
 MECHANICAL PER FBC-EB 709.1. SHOW THE EXISTING HOUSE
 WITHOUT THESE WINDOWS WILL MEET THE VENTILATION
 REQUIREMENTS OF FBC-M SECTION 402 OR 403.
  
 7. PLEASE SEE PLUMBING COMMENTS REGARDING SIGNATURE,
 SEAL AND TITLE BLOCK OF THE DESIGN PROFESSIONAL.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT:
 RONALD J. REGUEIRO
 561.805.6719
 [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2009-07-20 Cont ID  
Sent By kstevens Date 2009-07-20 Time 16:29 Rev Time 0.00
Received By kstevens Date 2009-07-20 Time 16:29 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2009-06-02 Cont ID  
Sent By kstevens Date 2009-06-02 Time 15:02 Rev Time 0.00
Received By kstevens Date 2009-06-02 Time 15:02 Sent To  
Notes
2009-06-02 15:16:13DENIED
 REFERENCE:
 FBC-2007 W/2009 SUPPLEMENTS
 FBC-2007 CHAPTER 1
 FBC-2007 RESIDENTIAL
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1. THE INDEX OF DRAWINGS DOES NOT REFLECT THE SHEETS
 SUBMITTED. PLEASE CORRELATE. SECTION 106.1.3.
  
 2. SHT 10.0 CLEANOUTS ARE REQUIRED NEAR THE JUNCTION OF
 THE BUILDING DRAIN AND THE BUILDING SEWER. SECTION
 P3005.2.7. PLEASE SHOW ON FLAT PLUMBING PLAN AND
 ISOMETRIC RISER DIAGRAM.
  
 3. SOME SHEETS ARE NOT SIGNED, SEALED AND DATED AS
 REQUIRED IN FAC 61G15-23.002(2) & FS 471.025. PLEASE
 SIGN, SEAL & DATE ALL SHEETS PREPARED BY THE DESIGN
 PROFESSIONAL.
  
 4. SHTS 2.0 & 10.0 INDICATE THE DESIGN TO BE PER
 FBC-2004 W/2007 AMENDMENTS. THE CODE CYCLE IN EFFECT
 SINCE MARCH 1, 2009 IS THE FBC-2007 W/2009 SUPPLEMENTS.
 PLEASE SHOW THE CORRECT CODE CYCLE FOR THE PLANS
 SUBMITTED.
  
 5. ALL SHTS. THE CERTIFICATE OF AUTHORIZATION NUMBER IS
 REQUIRED IN THE TITLE BLOCK OF ALL SHEETS. THE NUMBER
 IS MISSING FROM THE TITLE BLOCK OF ALL SHEETS. FAC
 61G15-23.002(2) & FS 471.025.
  
 6. ALL SHEETS WITH S.W. ENGINEERING INC. TITLE BLOCKS.
 THE ADDRESS IS REQUIRED IN THE TITLE BLOCK. THE ADDRESS
 INDICATED, (21218 ST ANDREWS BLVD), DOES NOT REFLECT
 THE ADDRESS OF RECORD IN THE STATE OF FLORIDA DEPT OF
 BUSINESS AND PROFESSIONAL REGULATION, (DBPR) WEBSITE,
 (107 WINGED FOOT LANE). PLEASE UPDATE THE TITLE BLOCKS
 OR THE DBPR WEBSITE PRIOR TO RESUBMITTING FOR REVIEW IN
 THE CITY OF WPB. FAC 61G15-23.002(2) & FS 471.025.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUMBER,
 WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE
 ALL VOID SHEETS FROM ALL PLANS AND PLACE
 ONE SET OF THEM LOOSELY ON TOP OF THE
 COLLATED PLANS TO BE REVIEWED.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]
  

Review Stop Z ZONING
Rev No 6 Status P Date 2010-09-14 Cont ID  
Sent By astelly Date 2010-09-14 Time 16:28 Rev Time 0.00
Received By astelly Date 2010-09-14 Time 16:28 Sent To  
Notes
2010-09-14 16:31:25AMY STELLY
 PLANNING AND ZONING
 561-822-1442
  
 PASSED W/ PROVISO
  
 LANDSCAPE COMMENTS FOR PERMIT # 10070231 MUST BE
 SATISFIED.

Review Stop Z ZONING
Rev No 5 Status F Date 2010-04-08 Cont ID  
Sent By astelly Date 2010-04-08 Time 14:32 Rev Time 0.00
Received By astelly Date 2010-04-08 Time 16:02 Sent To L
Notes
2010-04-08 16:04:00AMY STELLY
 PLANNING AND ZONING
 561-822-1442
  
  
 COMMENTS FOR THE LANDSCAPE REVIEW MUST BE SATISFIED IN
 ORDER TO PASS THE ZONING REVIEW.

Review Stop Z ZONING
Rev No 4 Status F Date 2010-04-07 Cont ID  
Sent By astelly Date 2010-02-12 Time 09:50 Rev Time 0.00
Received By astelly Date 2010-02-12 Time 09:50 Sent To  
Notes
2010-02-12 17:27:18AMY STELLY
 PLANNING AND ZONING
 822-1442
  
  
 PLEASE SUBMIT A SURVEY OF THE PROPERTY PURSUANT TO
 COMMENTS FROM PREVIOUS ZONING REVIEWS. SURVEY IS NOT
 ATTACHED TO RECORD DRAWINGS ON FILE WITH THE CITY.

Review Stop Z ZONING
Rev No 3 Status F Date 2009-08-27 Cont ID  
Sent By mcruz Date 2009-08-27 Time 19:00 Rev Time 0.00
Received By mcruz Date 2009-08-27 Time 18:50 Sent To  
Notes
2009-08-27 19:00:01PLANNING AND ZONING DEPT: ***ZONING FAILED - 2ND
 RESUB***
  
 1. PLEASE PROVIDE ALL RESPONSES IN WRITING.
  
 2. REPEAT COMMENT (HAVE NOT RECEIVED YET): PROVIDE TWO
 (2) COPIES OF A CURRENT SURVEY, WHICH INCLUDES THE
 PROPERTY'S ADDRESS AND LEGAL DESCRIPTION.
  
 2. DUE TO INCREASE IN THE PROJECT VALUATION FROM
 $3,000.00 TO $39,000.00 THE PROPOSED WORK NOW EXCEEDS
 50% OF THE STRUCTURE'S VALUE AS LISTED IN THE PBC
 PROPERTY APPRAISER'S OFFICE. PURSUANT TO THE CITY OF
 WEST PALM BEACH ZONING AND LAND DEVELOPMENT REGULATIONS
 (ZLDR), SECTION 94-441(C)(2) OF: AS THE VALUE OF THE
 PROPOSED WORK EXCEEDS 50% OF THE STRUCTURE'S VALUE
 (LISTED AS "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY
 APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE
 WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF
 THE ZLDR.
  
 PLEASE SUBMIT TWO (2) COPIES OF A LANDSCAPE PLAN
 SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF
 THE ZLDR.
  
 NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY
 GENERATE ADDITIONAL COMMENTS.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  

Review Stop Z ZONING
Rev No 2 Status F Date 2009-07-13 Cont ID  
Sent By mcruz Date 2009-07-13 Time 16:06 Rev Time 0.00
Received By mcruz Date 2009-07-13 Time 16:02 Sent To  
Notes
2009-07-13 16:06:45PLANNING AND ZONING DEPT: ***ZONING FAILED***
  
 1. PLEASE PROVIDE ALL RESPONSES IN WRITING.
  
 REPEAT COMMENT:
  
 2. PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH
 INCLUDES THE PROPERTY'S ADDRESS AND LEGAL DESCRIPTION.
  
 3. INDICATE ON THE SURVEY ANF SITE PLAN THE SEPARATION
 DISTANCE OF THE PROPOSED ADDITION TO THE EXISTING
 DETACHED GARAGE. NOTE: PURSUANT TO SECTION 94-304(B)(3)
 OF THE ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDR),
 ACCESSORY STRUCTURES SHALL BE LOCATED NO CLOSER THAN
 SIX (6) FEET TO THE PRINCIPAL STRUCTURE.
  
 NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY
 GENERATE ADDITIONAL COMMENTS.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date 2009-06-01 Cont ID  
Sent By mcruz Date 2009-06-01 Time 14:16 Rev Time 0.00
Received By mcruz Date 2009-06-01 Time 14:15 Sent To E
Notes
2009-06-01 14:16:08PLANNING AND ZONING DEPT: ***ZONING FAILED***
  
 1. PLEASE PROVIDE ALL RESPONSES IN WRITING.
  
 2. PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH
 INCLUDES THE PROPERTY'S ADDRESS AND LEGAL DESCRIPTION.
  
 NOTE: THE SUBMITTAL OF THE REQUESTED INFORMATION MAY
 GENERATE ADDITIONAL COMMENTS.
  
 FOR ADDITIONAL INFORMATION, THE ZONING AND LAND
 DEVELOPMENT REGULATIONS MAY BE VIEWED ONLINE AT
 WWW.MUNICODE.COM OR VISIT THE CITY OF WEST PALM BEACH
 PLANNING DEPARTMENT WEBSITE AT
 WWW.CITYOFWPB.COM/PLAN/INDEX.HTM.
  
 IF YOU HAVE ANY QUESTIONS, PLEASE DO NOT HESITATE TO
 CONTACT ME.
  
 MAGGIE CRUZ, ASSOCIATE PLANNER
 PLANNING AND ZONING DEPARTMENT
 TEL: (561) 822-1444 OR (561) 805-6720
 E-MAIL: [email protected]
  
 PLACED IN ELEC BOX