Plan Review Details - Permit 09050475
| Plan Review Stops For Permit 09050475 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2009-05-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-05-27 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-05-27 |
Time |
13:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2009-05-22 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-05-22 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-05-22 |
Time |
16:19 |
Sent To |
PC |
|
| Notes |
| 2009-05-22 16:24:23 | RESIDENTIAL (R3) RE-ROOF, BUILDING REVIEW CHECKLIST. | | | REVIEW UNDER 2007 FLORIDA RESIDENTIAL CODE WITH 2009 | | | REVISIONS. | | | | | | 1- NEED TO PROVIDE SIGNED AND SEALED RAS 117 | | | CALCULATIONS FOR NAIL ENHANCING AT PERIMETER AND CORNER | | | AREAS AS REQUIRED BY GENERAL LIMITATION #7 ON SHEET 20 | | | OF 20 OF NOA 08-0512.06 SUBMITTED. ASSEMBLY SELECTED ON | | | SHEET 19 OF 20 IS GOOD FOR A MAXIMUM DESIGN PRESSURE OF | | | -52.5PSF. NEED TO PROVIDE NAIL ENHANCING FOR PERIMETER | | | AND CORNER AREAS IN ORDER TO MEET THE DESIGN PRESSURES | | | REQUIREMENTS OF SEC. R301 OF 2007 FLORIDA RESIDENTIAL | | | CODE. | | | ***NOTE: DESIGN PROFESSIONAL DOING THE CALCULATIONS | | | NEEDS TO TAKE INTO CONSIDERATION THAT ACCORDING TO THE | | | 2009 REVISIONS TO THE 2007 FLORIDA RESIDENTIAL CODE, | | | THIS BUILDING IS LOCATED ON EXPOSURE "C". SEE SEC. R301 | | | OF 2009 REVISIONS FOR REVISIONS DONE TO THE EXPOSURE | | | CATEGORY. | | | | | | 2- VALUATION DECLARED IN THE PERMIT APPLICATION IS TOO | | | LOW. VALUATION WAS UPDATED AS REQUIRED BY SEC. 108.3 | | | CITY AMENDMENTS TO FBC. OWES $78.17 FOR UPDATED | | | VALUATION. | | | | | | 3- NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY | | | SEC. 713.13 FLORIDA STATUTE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CALL | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2009-05-22 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2009-05-22 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2009-05-22 |
Time |
16:19 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy