| Plan Review Stops For Permit 09050468 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
N |
Date |
2009-07-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-07-14 |
Time |
13:07 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2009-07-09 |
Time |
15:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2009-07-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-07-14 |
Time |
13:15 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2009-07-14 |
Time |
12:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2009-06-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2009-06-01 |
Time |
15:30 |
Rev Time |
1.00 |
| Received By |
jwitmer |
Date |
2009-06-01 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2009-06-01 15:38:58 | BUILDING PLAN REVIEW | | | PERMIT: 09050468 | | | ADD: 901 N FLAGLER DR | | | CONT: RYBEK CONSTRUCTION | | | TEL: (561)798-5122 | | | | | | FL BLD CODE= 2007 FLORIDA BUILDING CODE | | | W/ 2009 FBC SUPPLEMENTS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 1 ST REVIEW | | | ACTION: PROVISO | | | | | | 1) PLANS SUBMITTED FOR PERMIT (FIRST TIME REVIEW) AFTER | | | MARCH 1ST, 2009 SHALL BE REVIEWED TO THE 2007 FBC | | | BUILDING WITH 2009 SUPPLEMENTS, THE 2007 EXISTING | | | BUILDING CODE WITH | | | 2009 SUPPLEMENTS. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2009-07-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-07-05 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-07-05 |
Time |
14:43 |
Sent To |
|
|
| Notes |
| 2009-07-05 14:44:49 | LOW VOLTAGE PERMIT(S) UNDER SEPARATE PERMIT. | | | | | | MAY REFERENCE THESE EPLANS FOR THE WORK ALREADY SHOWN | | | FOR DATA/PHONE. PERMIT CAN BE TURN AROUND FOR THIS | | | SCOPE AS SHOWN. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2009-06-01 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2009-06-01 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2009-06-01 |
Time |
08:36 |
Sent To |
|
|
| Notes |
| 2009-06-01 08:36:49 | *** DENIED REVIEW **** | | | | | | | | | 1) NOTE: PLEASE ADJUST AND CORRECT SOME OF THE | | | FOLLOWING CODES ON PLANS. | | | PLANS NEED TO STATE THE FOLLOWING. | | | 2007 FBC W/ 2009 GLITCH AMENDMENTS. ( PLANS STATE 2007 | | | AND 2008/ GLITCH AMENDMENTS ) | | | | | | 2002 NFPA-72. (PLANS STATE 2006) | | | | | | 2006 NFPA-1 (PLANS STATE 2007 FIRE PREVENTION CODE. | | | NFPA-1 IS THE FIRE PREVENTION CODE) | | | | | | 2) NOTE: PLEASE SUBMIT LIGHTING PERFORMANCE | | | CALCULATIONS PER 13-415.AB.5 | | | | | | 3) NOTE: PLEASE IDENTIFY ALL CIRCUITS SPECIFIC TO ROOMS | | | AND AREAS IN WHICH THEY FEED. THESE MAY BE ALPHA OR | | | NUMERIC DESIGNATIONS. PLANS STATE THE WORDING OF | | | *NOTES* ON MANY OF THE SPACES. WHAT NOTES ARE THESE AS | | | SOME OF THE NOTES ON THE PLANS DO NOT SEEM TO | | | COORDINATE WITH THE PANELS WITH WHAT THEY WOULD BE? | | | PLEASE SEE NEC HANDBOOK COMMENTARY UNDER 408..4 AS ALL | | | CIRCUITS NEED TO BE SPECIFIC. | | | | | | 4) NOTE: PLEASE COORDINATE PANEL AND SERVICE | | | CALCULATIONS. PANEL IS NOTED AS BEING A 150AMP PANEL, | | | HOWEVER THE CALCULATIONS NOTE THE EXISTING PANEL IS | | | 200AMP. | | | 240,408, ETC | | | FBC 106.1.1 FOR CLARITY AND COORDINATION. | | | | | | | | | | | | | | | | | | | | | * IMPORTANT ** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC. SHOULD BE PLACED | | | INTO TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | IF THERE ARE ANY QUESTIONS; OR IF COMMENTS ARE NOT | | | TYPED IN A CLEAR MANNER PLEASE DO NOT HESITATE TO | | | CONTACT THIS REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2009-07-21 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2009-07-21 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2009-07-21 |
Time |
09:46 |
Sent To |
B |
|
| Notes |
| 2009-07-21 10:01:21 | *****APPROVED***** | | | | | | PLAN SHEETS D1, 1 (OF 3), AND 2 (OF 3) WERE STAMPED, | | | INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2009-06-16 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2009-06-16 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2009-06-16 |
Time |
13:17 |
Sent To |
|
|
| Notes |
| 2009-06-16 13:22:35 | SEPARATE SHOP DRAWINGS AND PERMITS REQUIRED FOR FIRE | | | SPRINKLER AND FIRE ALARM REMODEL IF APPLICABLE. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2009-06-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2009-06-22 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2009-06-22 |
Time |
09:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2009-06-16 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2009-06-16 |
Time |
13:33 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2009-05-22 |
Time |
15:22 |
Sent To |
|
|
| Notes |
| 2009-05-22 15:22:20 | TO C-5 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2009-07-20 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-07-20 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-07-20 |
Time |
14:52 |
Sent To |
FIRE |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2009-06-12 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2009-06-12 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2009-06-12 |
Time |
16:19 |
Sent To |
|
|
| Notes |
| 2009-06-12 16:20:34 | **PROVISO** | | | | | | RETURN AIR TRANSFER DUCT IN EXAM ROOM SHALL BE MIN. 9" | | | ROUND TO MEET EXCEPTION UNDER FBC-M 601.4 FOR BALANCED | | | RETURN. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2009-07-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-07-06 |
Time |
12:10 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-07-06 |
Time |
12:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2009-06-01 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2009-06-01 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2009-06-01 |
Time |
11:43 |
Sent To |
|
|
| Notes |
| 2009-06-01 13:51:41 | DENIED | | | REFERENCE: | | | FBC-2007 W/2009 SUPPLEMENTS | | | FBC-2007 EXISTING BUILDING | | | FBC-2007 PLUMBING | | | FBC-2007 CHAPTER 11 | | | FBC-2007 CHAPTER 1 | | | | | | 1. SHT D-1 CODE REFERENCES TO READ FBC-2007 WITH 2009 | | | SUPPLEMENTS. SECTION 106.1.1. | | | | | | 2. SHT D-1 IN THE REMOVAL OF ANY PART OF A DRAINAGE | | | SYSTEM, DEAD ENDS SHALL BE PROHIBITED. ALL REMOVAL OF | | | PIPING SHALL BE WITH 2 FEET OF AN ACTIVE BRANCH LINE OR | | | BUILDING DRAIN LINE. SECTION 704.5. SOME LINES APPEAR | | | TO BE MORE THAN 2 FEET. (SEE RISER DIAGRAM ON SHEET 3 | | | OF 3). | | | | | | 3. THE FOLLOWING INFORMATION IS REQUIRED TO SHOW | | | COMPLIANCE: | | | ___FOR W.C'S: | | | A. 11-4.16.5 FLUSH CONTROLS | | | ___FOR LAVS: | | | A. 11-4.19.2 HEIGHT & CLEARANCES | | | B. 11-4.19.4 EXPOSED PIPES & SURFACES | | | C. 11-4.19.5 FAUCETS | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE | | | ALL VOID SHEETS FROM ALL PLANS AND PLACE | | | ONE SET OF THEM LOOSELY ON TOP OF THE | | | COLLATED PLANS TO BE REVIEWED. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2009-05-29 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2009-05-29 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2009-05-29 |
Time |
10:45 |
Sent To |
|
|
| Notes |
|
|